Energy and Exergy Analysis of a Coal Fired Power Plant

被引:19
|
作者
Kumar, Sumeet [1 ]
Kumar, Dileep [1 ]
Memon, Rizwan Ahmed [2 ]
Wassan, Majid Ali [1 ]
Ali, Mir Skindar [1 ]
机构
[1] Mehran Univ Engn & Technol, Dept Mech Engn, Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mirs, Pakistan
[2] Mehran Univ Engn & Technol, Dept Mech Engn, Jamshoro, Pakistan
关键词
Energy Analysis; Exergy Analysis and Wisconsin Power and Light Company;
D O I
10.22581/muet1982.1804.13
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, energy and exergy analysis has been conducted on a subcritical coal fired power plant of Wisconsin Power and Light Company, USA to investigate the steam cycle energy and exergy efficiency. The cycle is analyzed by developing a mathematical model using its operating and design parameters. The analysis is performed using EES (Engineering Equation Solver). The energy analysis shows that major share of energy loss occurs in condenser i.e. 72% of total cycle energy loss, whereas, exergy analysis shows that 83.09% total exergy destruction of cycle occurs in boiler. Furthermore, the simulation results are compared with actual with an absolute error of 3.1%. Additionally, the parametric study is performed to examine the effects of various operating parameters such as main steam pressure and temperature, condenser pressure, terminal and drain cooler temperature difference on net power output, energy andexergy efficiency of cycle. The parametric study shows that the plant has maximum energy and exergy efficiencies at steam pressure of 2500psi, condenser pressure of 1.0psi and main steam temperature of 1100 degrees F. Furthermore, these parameters do not seem to change energy and exergy efficiencies significantly.
引用
收藏
页码:611 / 624
页数:14
相关论文
共 50 条
  • [31] Energy and exergy analysis of a steam power plant in Jordan
    Aijundi, Isam H.
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) : 324 - 328
  • [32] Exergy analysis of coal fired tea drying furnace
    Sinha, Abhijit
    Gupta, Rajat
    Pandey, Krishna Murari
    Dey, Sanjoy Kumar
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2015, 17 (01) : 54 - 73
  • [33] Energy, exergy, and economic analysis of a geothermal power plant
    Kazemi, Hamid
    Ehyaei, M.A.
    [J]. Advances in Geo-Energy Research, 2018, 2 (02): : 190 - 209
  • [34] Energy and Exergy Analysis of Dieng Geothermal Power Plant
    Qurrahman, Alfian Hardi
    Wilopo, Wahyu
    Susanto, Sigit Ponco
    Petrus, Himawan Tri Bayu Murti
    [J]. INTERNATIONAL JOURNAL OF TECHNOLOGY, 2021, 12 (01) : 175 - 185
  • [35] Application of exergy and entransy concepts to analyses performance of coal fired thermal power plant: a case study
    Geete, Ankur
    [J]. INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (09) : 1032 - 1043
  • [36] Application of exergy and entransy concepts to analyses performance of coal fired thermal power plant: a case study
    [J]. Geete, Ankur (ankur_geete@yahoo.co.in), 1600, Taylor and Francis Ltd. (42):
  • [37] Component and process based exergy evaluation of a 600MW coal-fired power plant
    Wu, Lingnan
    Wang, Ligang
    Wang, Yang
    Hu, Xiaoying
    Dong, Changqing
    Yang, Zhiping
    Yang, Yongping
    [J]. INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 2097 - 2100
  • [38] Dynamic performance and control strategy comparison of a solar-aided coal-fired power plant based on energy and exergy analyses
    Yan, Hui
    Liu, Ming
    Chong, Daotong
    Wang, Chaoyang
    Yan, Junjie
    [J]. ENERGY, 2021, 236
  • [39] Advanced Energy, Exergy, and Environmental (3E) Analyses and Optimization of a Coal-Fired 400 MW Thermal Power Plant
    Hoseinzadeh, Siamak
    Heyns, P. Stephan
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2021, 143 (08):
  • [40] Exergy and Economic Evaluation of a Hybrid Power Plant Coupling Coal with Solar Energy
    Serrano-Sanchez, Cristina
    Olmeda-Delgado, Marina
    Petrakopoulou, Fontina
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (05):