INVITRO STUDY OF THE TRANSFER OF CYTOKINE-INDUCING SUBSTANCES ACROSS SELECTED HIGH-FLUX HEMODIALYSIS MEMBRANES

被引:64
|
作者
EVANS, RC [1 ]
HOLMES, CJ [1 ]
机构
[1] BAXTER HLTH CORP,DIV RENAL,POB 490,ROUND LAKE,IL 60073
关键词
HIGH-FLUX MEMBRANES; CYTOKINE-INDUCING SUBSTANCES; ENDOTOXIN; PSEUDOMONAS-AERUGINOSA;
D O I
10.1159/000170002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The in vitro transfer of cytokine-inducing substances (CIS) across cellulose triacetate and polyacrylonitrile hollow-fiber high-flux hemodialyzers was studied using culture filtrates of gram-negative bacteria isolated from hemodialysis center environments. With Enterobacter cloacae, no transfer of CIS was seen despite the potent cytokine inducibility and endotoxin content of the challenge solution. In contrast, interleukins 1 and 6 and tumor necrosis factor inducing substances did penetrate both dialyzer types challenged with Pseudomonas aeruginosa culture filtrates containing a high endotoxin content. Transfer was not seen, however, upon dilution of the challenge solution to lower, yet clinically very high levels of endotoxin. These results show that, in vitro, the transfer of CIS across high-flux membranes is critically dependent upon the quality and the quantity of the challenge material employed.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 50 条
  • [11] DO CYTOKINE-INDUCING SUBSTANCES PENETRATE THROUGH DIALYSIS MEMBRANES AND STIMULATE MONOCYTES
    KUMANO, K
    YOKOTA, S
    NANBU, M
    SAKAI, T
    [J]. KIDNEY INTERNATIONAL, 1993, 43 : S205 - S208
  • [12] THE ROLE OF PLASMA COATING ON THE PERMEATION OF CYTOKINE-INDUCING SUBSTANCES THROUGH DIALYZER MEMBRANES
    LONNEMANN, G
    SCHINDLER, R
    LUFFT, V
    MAHIOUT, A
    SHALDON, S
    KOCH, KM
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1995, 10 (02) : 207 - 211
  • [13] High-Flux and Low-Flux Membranes in Hemodialysis
    Oshvandi, Khodayar
    Kavyannejad, Rasol
    Borzuo, Sayed Reza
    Gholyaf, Mahmoud
    [J]. NURSING AND MIDWIFERY STUDIES, 2014, 3 (03)
  • [14] Hemodiafiltration and high-flux hemodialysis with polyethersulfone membranes
    David, S
    Gerra, D
    De Nitti, C
    Bussolati, B
    Teatini, U
    Longhena, GR
    Guastoni, C
    Bellotti, N
    Combarnous, F
    Tetta, C
    [J]. POLYETHERSULFONE: MEMBRANES FOR MULTIPLE CLINICAL APPLICATIONS, 2003, 138 : 43 - 54
  • [15] REMOVAL OF VANCOMYCIN BY HIGH-FLUX HEMODIALYSIS MEMBRANES
    QUALE, JM
    OHALLORAN, JJ
    DEVINCENZO, N
    BARTH, RH
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1992, 36 (07) : 1424 - 1426
  • [16] CLINICAL-STUDY OF HIGH-FLUX CUPRAMMONIUM RAYON HEMODIALYSIS MEMBRANES
    OPATRNY, K
    SULKOVA, S
    LOPOT, F
    VIT, L
    VALEK, A
    OPATRNY, K
    [J]. ARTIFICIAL ORGANS, 1993, 17 (12) : 971 - 976
  • [17] EFFECTIVE CLEARANCE OF METHOTREXATE USING HIGH-FLUX HEMODIALYSIS MEMBRANES
    WALL, SM
    MADDEN, T
    DUBOSE, TD
    BARCLAY, C
    MOLONY, D
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 405 - 405
  • [18] High-flux membranes normalize mRNA expression and improve cytokine synthesis in hemodialysis (HD) patients (pts).
    Pertosa, G
    Grandaliano, G
    Ranieri, E
    Monno, R
    Gesualdo, L
    Schena, FP
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A1228 - A1228
  • [19] HEMODIALYSIS USING HIGH-FLUX MEMBRANES IMPROVES LIPID PROFILES
    BLANKESTIJN, PJ
    [J]. CLINICAL NEPHROLOGY, 1994, 42 : S48 - S51
  • [20] OXALATE CLEARANCE BY HIGH-FLUX HEMODIALYSIS USING POLYACRYLONITRILE MEMBRANES
    SETHI, D
    MORGAN, SH
    PURKISS, P
    CURTIS, JR
    WATTS, RWE
    [J]. CURRENT THERAPY IN NEPHROLOGY, 1989, 24 : 379 - 381