APPLICATION OF A MICROWAVE-INDUCED PLASMA ATOMIC EMISSION DETECTOR FOR QUANTIFICATION OF HALOGENATED COMPOUNDS BY GAS-CHROMATOGRAPHY

被引:30
|
作者
KOVACIC, N
RAMUS, TL
机构
[1] Dow Chemical Company, Pittsburg, CA 94565
关键词
MICROWAVE-INDUCED PLASMA; GAS CHROMATOGRAPHIC DETECTION; COMPOUND INDEPENDENT CALIBRATION; ATOMIC EMISSION DETECTOR;
D O I
10.1039/ja9920700999
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A series of halogenated and oxygenated heterocyclic, aromatic and aliphatic compounds were evaluated for elemental calibration with the atomic emission detector for gas chromatography (GC-AED). The GC-AED monitored C, Cl, F, N and O signals for these compounds and elemental response factors (ERF) were evaluated for compound independence. The variation in ERF for C, Cl, F, N and O were evaluated and found to be less than 3, 6, 5, 6 and 5% relative standard deviation (RSD), respectively, for all the compounds tested. Significant ERF compound dependence was identified for Cl in one of the compound groups and F in all compound groups. However, the ERF variation only increased from 5 to 6% RSD for Cl and from 2 to 5% RSD for F after including the compound dependent bias. Compound independent calibration can be utilized if these errors are acceptable for a particular application. The linearity of ERF with concentration and GC-AED reagent gas composition were also evaluated.
引用
收藏
页码:999 / 1005
页数:7
相关论文
共 50 条
  • [31] QUANTITATIVE CHARACTERISTICS OF MICROWAVE PLASMA EMISSION SPECTROMETRIC DETECTOR FOR GAS-CHROMATOGRAPHY
    YU, W
    HUANG, Y
    OU, Q
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 155 - ANYL
  • [32] OXYGEN-SELECTIVE MICROWAVE-INDUCED PLASMA GAS-CHROMATOGRAPHY DETECTOR FOR PETROLEUM-RELATED SAMPLES
    BRADLEY, C
    CARNAHAN, JW
    ANALYTICAL CHEMISTRY, 1988, 60 (09) : 858 - 863
  • [33] An improved argon microwave-induced plasma ionization detector for gas chromatography
    Jin, QH
    Shi, YH
    Yu, AM
    Yang, WJ
    Peng, ZH
    MICROCHEMICAL JOURNAL, 1999, 62 (02) : 282 - 290
  • [34] Microwave-induced plasma atomic emission spectrometer used as the detector for on-line coupled high-performance liquid chromatography gas chromatography
    Jia, CR
    Wang, XH
    Ou, QY
    ANALYTICAL COMMUNICATIONS, 1997, 34 (02): : 53 - 56
  • [35] DEVELOPMENT OF A MICROWAVE PLASMA DETECTOR FOR GAS-CHROMATOGRAPHY
    CHEVRIER, G
    HANAI, T
    TRAN, KC
    HUBERT, J
    CANADIAN JOURNAL OF CHEMISTRY, 1982, 60 (07) : 898 - 903
  • [36] MICROWAVE-INDUCED PLASMA EMISSION SPECTROPHOTOMETER COMBINED WITH A PHOTODIODE ARRAY MONITOR FOR CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    TAKIGAWA, Y
    HANAI, T
    HUBERT, J
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (11): : 698 - 702
  • [37] TRACE ANALYSIS FOR STEROIDAL CARBORANES VIA GAS-CHROMATOGRAPHY MICROWAVE-INDUCED PLASMA EMISSION SPECTROSCOPIC DETECTION
    KRULL, IS
    JORDAN, SW
    KAHL, S
    SMITH, SB
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1982, 20 (11) : 489 - 498
  • [39] DETERMINATION OF POLYCHLORINATED-BIPHENYLS IN BIOTIC MATRICES USING GAS-CHROMATOGRAPHY MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    HAJSLOVA, J
    CUHRA, P
    KEMPNY, M
    POUSTKA, J
    HOLADOVA, K
    KOCOUREK, V
    JOURNAL OF CHROMATOGRAPHY A, 1995, 699 (1-2) : 231 - 239
  • [40] ATOMIC EMISSION DETECTOR FOR GAS-CHROMATOGRAPHY AND SUPERCRITICAL FLUID CHROMATOGRAPHY
    JIN, QH
    WANG, FD
    ZHU, C
    CHAMBERS, DM
    HIEFTJE, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) : 487 - 494