Comparison of outcome in 1809 patients treated with drug-eluting stents or bare-metal stents in a real-world setting

被引:2
|
作者
Vogt, Alexander [1 ]
Schoelmerich, Anke [1 ]
Pollner, Franziska [1 ]
Schlitt, Manuela [1 ]
Raaz, Uwe [1 ]
Maegdefessel, Lars [2 ]
Reindl, Iris [1 ]
Buerke, Michael [1 ]
Werdan, Karl [1 ]
Schlitt, Axel [1 ]
机构
[1] Martin Luther Univ Halle Wittenberg, Dept Med 3, Ernst Grube Str 40, D-06120 Halle, Germany
[2] Stanford Univ, Sch Med, Div Cardiovasc Med, Stanford, CA USA
关键词
coronary stent; outcome; renal insufficiency; myocardial infarction; STEMI;
D O I
10.2147/VHRM.S24370
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: The aim of this study was to determine the long-term safety of drug-eluting stent (DES) versus bare metal stent (BMS) implantation in a "real-world" setting. Patients and methods: A total of 1809 patients who were treated with implantation of either BMS or DES were assessed. Kaplan-Meier and multivariate Cox regression analyses concerning primary endpoint of cardiac mortality were performed. Results: A total of 609 patients received DES. Mean age was 66.2 +/- 11.3 years, 69.4% were male, and 1517 (83.8%) were treated for acute coronary syndrome (unstable angina 510 [28.2%], non-ST-elevation myocardial infarction [NSTEMI] 506 [28.0%], and ST-elevation myocardial infarction [STEMI] 501 [27.7%]). Mean follow-up was 34 +/- 15 months. During follow-up, 268 patients died of cardiac causes (DES 42 [7.3%]; BMS 226 [19.6%]; P < 0.001).-Univariate Kaplan-Meier analysis showed an advantage of DES over BMS concerning the primary endpoint (P, 0.001). When adjusting for classic risk factors and additional factors that affect the progression of coronary heart disease (CHD), DES was not found to be superior to BMS (hazard ratio 0.996, 95% confidence interval 0.455-2.182, P = 0.993). Severely impaired renal function was an independent predictor for cardiac mortality after stent implantation. Conclusion: Treatment with DES is safe in the long term, also in patients presenting with STEMI. However, in multivariate analyses it is not superior to BMS treatment.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 50 条
  • [31] Bare-metal versus drug-eluting coronary stents - Reply
    Marroquin, Oscar C.
    Mulukutla, Suresh R.
    Kip, Kevin E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (23): : 2517 - 2518
  • [32] Drug-eluting or bare-metal stents for acute myocardial infarction
    Mauri, Laura
    Silbaugh, Treacy S.
    Garg, Pallav
    Wolf, Robert E.
    Zelevinsky, Katya
    Lovett, Ann
    Varma, Manu R.
    Zhou, Zheng
    Normand, Sharon-Lise T.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (13): : 1330 - 1342
  • [33] Drug-Eluting or Bare-Metal Stents in Large Coronary Arteries
    van Bemmel, Marnix W.
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (12): : 1179 - 1179
  • [34] Drug-Eluting versus Bare-Metal Stents: When and for Whom?
    Beyar, Rafael
    Nikolsky, Eugenia
    JOURNAL OF INVASIVE CARDIOLOGY, 2008, 20 (03): : 105 - 106
  • [35] A comparison of bare-metal and drug-eluting stents for off-label indications
    Marroquin, Oscar C.
    Selzer, Faith
    Mulukutla, Suresh R.
    Williams, David O.
    Vlachos, Helen A.
    Wilensky, Robert L.
    Tanguay, Jean-Francois
    Holper, Elizabeth M.
    Abbott, J. Dawn
    Lee, Joon S.
    Smith, Conrad
    Anderson, William D.
    Kelsey, Sheryl F.
    Kip, Kevin E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (04): : 342 - 352
  • [36] Comparison of Drug-Eluting and Bare-Metal Stents for Stable Coronary Artery Disease
    Horst, Brian
    Rihal, Charanjit S.
    Holmes, David R., Jr.
    Bresnahan, John F.
    Prasad, Abhiram
    Gau, Gerald
    Lennon, Ryan
    Lerman, Amir
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) : 321 - 328
  • [37] Drug-Eluting Balloons or Stents for Bare-Metal Stent Restenosis
    Wiebe, Jens
    Colleran, Roisin
    Kastrati, Adnan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (12) : 1256 - 1258
  • [38] 3-Year Comparison of Drug-Eluting Versus Bare-Metal Stents
    Applegate, Robert J.
    Sacrinty, Matthew T.
    Kutcher, Michael A.
    Santos, Renato M.
    Gandhi, Sanjay K.
    Little, William C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (03) : 231 - 239
  • [39] Effectiveness of drug-eluting stents in real-world patients
    Mukherjee, Debabrata
    Moliterno, David J.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (04): : 454 - 455
  • [40] Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
    Farshid, Ahmad
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (26): : 2604 - 2604