摘要
Abstract: A new kind of total implantable artificial heart (TIAH), developed by the author, offers miniaturization with good hemodynamic and physiologic properties. The heart has two units of function, and each has two blood sacs, compressed and expanded by twos, that are filled from one circulation and push out the blood in the other circulation, one after the other. Therefore, the blood flow is continuous and modulated, regulated by pneumatic controlled membrane valves. Shaped plates mechanically synchronized by a pushing rod control compression and expansion of the blood sacs. Starling, atrium, Windkessel, and Anrep effects are guaranteed by construction. The heart can be used for bridging toward transplantation, for definitive substitution of the heart, and for a new kind of therapy‐“extracorporeal regeneration of organs.” © 1990 International Society for Artificial Organs
引用
收藏
页码:284 / 289
页数:6
相关论文
共 50 条
  • [21] THE HELMHOLTZ TOTAL ARTIFICIAL-HEART LABTYPE
    KAUFMANN, R
    REUL, H
    RAU, G
    [J]. ARTIFICIAL ORGANS, 1994, 18 (07) : 537 - 542
  • [22] MECHANICAL ASPECTS OF THE TOTAL ARTIFICIAL-HEART
    UNGER, F
    ALBES, J
    [J]. WIENER MEDIZINISCHE WOCHENSCHRIFT, 1990, 140 (10-11) : 290 - 293
  • [23] PRELIMINARY PROJECT FOR A NEW TYPE OF ELECTROMAGNETIC TOTAL ARTIFICIAL-HEART
    MARTIGNONE, R
    [J]. MEDICINA-RIVISTA DELLA ENCICLOPEDIA MEDICA ITALIANA, 1985, 5 (02): : 233 - 234
  • [24] TOTAL ARTIFICIAL-HEART - SURVIVAL AND COMPLICATIONS
    MUNERETTO, C
    SOLIS, E
    PAVIE, A
    LEGER, P
    GANDJBAKHCH, I
    SZEFNER, J
    BORS, V
    PIAZZA, C
    CABROL, A
    CABROL, C
    [J]. ANNALS OF THORACIC SURGERY, 1989, 47 (01): : 151 - 157
  • [25] PHONOCARDIOGRAPHIC CHARACTERISTICS OF THE TOTAL ARTIFICIAL-HEART
    ANDERSON, FL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (01): : 205 - 206
  • [26] IMPLANTABLE ARTIFICIAL-HEART SYSTEM AND NEW ACTUATOR CONTROL BY POWER ELECTRONIC SYSTEM
    NISHIMURA, TH
    DING, L
    [J]. IEEE INTERNATIONAL CONFERENCE ON SYSTEMS ENGINEERING ///, 1989, : 289 - 292
  • [27] NEW LIFE FOR THE ARTIFICIAL-HEART
    BENOWITZ, SI
    [J]. SCIENCE NEWS, 1984, 126 (22) : 342 - 342
  • [28] MULTIGATED RADIONUCLIDE STUDY OF THE TOTAL ARTIFICIAL-HEART
    DATZ, FL
    CHRISTIAN, PE
    TAYLOR, A
    HASTINGS, WL
    DEVRIES, WC
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 13 (04): : 167 - 170
  • [29] TOTAL ARTIFICIAL-HEART (TAH) UTILIZATION IN MAN
    FRAZIER, OH
    AKUTSU, T
    COOLEY, DA
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 534 - 538
  • [30] THROMBUS WITH INFECTION IN TOTAL ARTIFICIAL-HEART ANIMALS
    CHIANG, BY
    OLSEN, DB
    BURNS, GL
    PANTALOS, GM
    EVERETT, S
    DEW, PA
    TATSUMI, E
    ROWLES, JR
    MOHAMMAD, F
    [J]. ARTIFICIAL ORGANS, 1992, 16 (04) : 371 - 376