ONLINE MASS-SPECTROMETER ANALYSIS OF GASIFICATION GAS

被引:6
|
作者
KARLEGARD, A [1 ]
GOTZ, A [1 ]
BJERLE, I [1 ]
机构
[1] DEPT KEAA,APPLICAT LAB,VACUUM TECHN & INSTRUMENTE,BALZERS 9496,LIECHTENSTEIN
关键词
D O I
10.1002/ceat.270180307
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The mass spectrometer is capable of making rapid, repetitive multicomponent analyses with measurement times as short as a second or less. Mass spectrometers used to be too expensive to be used for process analyses, but simpler and cheaper versions have been developed during the last decade. Mass spectrometers are commonly used within the petrochemical industry, but their use for fuel gas streams is not so widespread. This paper describes tests on a quadrupole mass spectrometer in three different gasification projects. Calibration methods and analysis accuracies obtained are accounted for. On the basis of the tests, it can be concluded that the quadrupole mass spectrometer is very suitable for continuous analysis of complex process streams. An important result is that the separation of CO and N-2, an analysis problem that is traditionally regarded as difficult, worked very well. The analysis frequency was approximately once per minute, which should be enough for most control loops.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 50 条
  • [21] AUTOMATIC CONTINUOUS ANALYSIS IN THE GAS AND LIQUID-PHASE WITH A MASS-SPECTROMETER
    HEINZELE, E
    FURNKAWA, DK
    CHEMIE INGENIEUR TECHNIK, 1983, 55 (07) : 588 - 589
  • [22] QUANTITATIVE GAS-ANALYSIS WITH QUADRUPOLE MASS-SPECTROMETER - CAPABILITY AND LIMITS
    BLEY, WG
    VAKUUM-TECHNIK, 1989, 38 (1-2): : 9 - 17
  • [23] QUADRUPOLE MASS-SPECTROMETER FOR RESIDUAL-GAS ANALYSIS AND SIMS APPLICATION
    HARS, G
    SOLYOM, A
    GIBER, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 341 (1-2): : 57 - 59
  • [24] MASS-SPECTROMETER
    MILLER, ER
    CARIGNAN, GR
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 338 : 34 - 38
  • [25] ONLINE ANALYSIS OF LIQUID STREAMS USING A MEMBRANE INTERFACE AND A QUADRUPOLE MASS-SPECTROMETER
    KEPHART, LA
    DULAK, JG
    SLIPPY, GA
    DEHEANDHANOO, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 86 - ENVR
  • [26] ONLINE ANALYSIS OF LIQUID STREAMS USING A MEMBRANE INTERFACE AND A QUADRUPOLE MASS-SPECTROMETER
    KEPHART, LA
    DULAK, JG
    SLIPPY, GA
    DHEANDHANOO, S
    ACS SYMPOSIUM SERIES, 1992, 508 : 178 - 189
  • [27] MASS-SPECTROMETER ANALYSIS OF A CESIUM PLASMA
    WITTING, HL
    JOURNAL OF APPLIED PHYSICS, 1969, 40 (01) : 236 - &
  • [28] ANALYSIS OF POLAR AND IONIC COMPOUNDS BY DESORPTIVE IONIZATION AND A TRIPLE ANALYZER MASS-SPECTROMETER MASS-SPECTROMETER
    GROSS, ML
    CROW, FW
    TOMER, KB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 186 (AUG): : 42 - ANYL
  • [29] MASS-SPECTROMETER FOR THE SECONDARY ION ANALYSIS
    DAUKEEV, DK
    KARETSKAYA, SP
    KASYMOV, SI
    KELMAN, VM
    MIT, AG
    SAICHENKO, NY
    SHEVELEV, GA
    ZHURNAL TEKHNICHESKOI FIZIKI, 1985, 55 (03): : 632 - 635
  • [30] A QUANTITATIVE MASS-SPECTROMETER FOR HYDROCARBON ANALYSIS
    STORY, M
    LASER, B
    HABFAST, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 48 (FEB): : 47 - 50