AN AUTOMATED-METHOD FOR THE DETERMINATION OF ACETYL AND PSEUDOCHOLINESTERASE IN HEMOLYZED WHOLE-BLOOD

被引:24
|
作者
MEULING, WJA
JONGEN, MJM
VANHEMMEN, JJ
机构
[1] Department of Occupational Toxicology, TNO Medical Biological Laboratory, Rijswijk
关键词
BIOLOGICAL MONITORING; CARBAMATE COMPOUNDS; ORGANOPHOSPHOROUS COMPOUNDS; COLORIMETRIC ASSAY; ACETYL CHOLINESTERASE; PSEUDOCHOLINESTERASE; PESTICIDE EXPOSURES;
D O I
10.1002/ajim.4700220208
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The aim of the present study was to develop a method which allows determination of pseudo (PsChE) and acetyl cholinesterase (AChE) activities in single hemolyzed blood samples of workers exposed to cholinesterase-inhibiting compounds, avoiding the time-consuming and laborious separation of plasma and erythrocytes. Two methods based on Ellman's colorimetric determination of cholinesterase activity were compared, and three different substrates were tested. The best results were obtained with the substrates butyrylthiocholine and acetyl(beta-methyl)thiocholine, both showing a substrate specificity of more than 97% with respect to PsChE and AChE, respectively. The method showed sensitivity to detect low levels of inhibition of AChE and PsChE in blood. The between-day precision was less than 4% for both cholinesterase activities. It was demonstrated with this method that hemolyzed blood can be stored at -20-degrees-C at least 18 months without loss of cholinesterase activity. The method has been used for 18 months in a monitoring program for laboratory employees working with various cholinesterase-inhibiting compounds. The average coefficients of intraindividual variation amounted to 6.8% (range 2.2-9.6%; 90 percentile, 8%) and 6.6% (range 2.9-9.9%; 90 percentile, 7.9%) for PsChE and AChE, respectively. In a group of non-exposed workers the average intraindividual variations were 4.0% (range 1.5-7.7%; 90 percentile, 7.6%) and 3.6% (range 0.6-6.6%; 90 percentile, 5.3%), respectively. Using the value of 4.0%, it appears possible to detect an individual decrease in cholinesterase activity of more than 8% below a baseline based on three determinations. The method can thus be used to detect relatively low levels of cholinesterase inhibition.
引用
收藏
页码:231 / 241
页数:11
相关论文
共 50 条
  • [41] HPLC DETERMINATION OF CYCLOSPORINE IN WHOLE-BLOOD
    HOFFMAN, NE
    RUSTUM, AM
    QUEBBEMAN, EJ
    HAMID, AAR
    AUSMAN, RK
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (13): : 2511 - 2520
  • [42] SPECTROPHOTOMETRIC DETERMINATION OF T-1824 IN WHOLE HEMOLYZED BLOOD
    NICHOLSON, JW
    NAHAS, GG
    WOOD, EH
    JOURNAL OF APPLIED PHYSIOLOGY, 1952, 4 (10) : 813 - 818
  • [43] DETERMINATION OF HYDRALAZINE IN HUMAN WHOLE-BLOOD
    LUDDEN, TM
    LUDDEN, LK
    WADE, KE
    ALLERHEILIGEN, SRB
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (06) : 693 - 695
  • [44] THE DETERMINATION OF TITANIUM AND VANADIUM IN WHOLE-BLOOD
    LUGOWSKI, S
    SMITH, DC
    VANLOON, JC
    TRACE ELEMENTS IN MEDICINE, 1987, 4 (01): : 28 - 34
  • [45] DETERMINATION OF MANGANESE IN HUMAN WHOLE-BLOOD
    WEISSMAN, N
    BABICHARMSTRONG, M
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1023 - 1023
  • [46] DETERMINATION OF MANGANESE IN WHOLE-BLOOD AND SERUM
    PLEBAN, PA
    PEARSON, KH
    CLINICAL CHEMISTRY, 1979, 25 (11) : 1915 - 1918
  • [47] DETERMINATION OF MANGANESE IN WHOLE-BLOOD AND SERUM
    VERSIECK, J
    CORNELIS, R
    LEMEY, G
    DERUDDER, J
    CLINICAL CHEMISTRY, 1980, 26 (03) : 531 - 532
  • [48] COMPARISON OF DETECTION OF ANTICONVULSANT DRUGS IN WHOLE-BLOOD, HEMOLYZED BLOOD AND PLASMA BY GAS-LIQUID CHROMATOGRAPHY
    PIPPENGER, CE
    SICHLER, DL
    CLINICAL CHEMISTRY, 1973, 19 (06) : 660 - 660
  • [49] METHOD FOR DETERMINATION OF PLATELET AND PLASMA MONOAMINE-OXIDASE IN WHOLE-BLOOD
    MARSHALL, EF
    CAMPBELL, IC
    BIOCHEMICAL PHARMACOLOGY, 1977, 26 (04) : 353 - 354
  • [50] DETERMINATION OF TOTAL HEMOGLOBIN IN WHOLE-BLOOD - FURTHER TESTS OF THE HEMOCUE METHOD
    ZWART, A
    BUURSMA, A
    KWANT, G
    OESEBURG, B
    ZIJLSTRA, WG
    CLINICAL CHEMISTRY, 1987, 33 (12) : 2307 - 2308