EXPERIMENTAL EVALUATION OF WATER SENSITIVITY IN POROUS MEDIA USING COMPUTERIZED TOMOGRAPHY SCANNING METHOD

被引:3
|
作者
Leng, Zhenpeng [1 ,2 ]
Lv, Weifeng [1 ]
Song, Xinmin [1 ]
Ma, Desheng [1 ]
Liu, Qingjie [1 ]
Liu, Hongxian [3 ]
Qin, Jianhua [3 ]
Jia, Ninghong [1 ]
Li, Tong [1 ]
机构
[1] Res Inst Petr Explorat & Dev, State Key Lab Enhanced Oil Recovery, Beijing, Peoples R China
[2] Peking Univ, Earth & Space Sci Sch, Beijing 100871, Peoples R China
[3] PetroChina Xinjiang Oilfield Co, Res Inst Explorat & Dev, Karamay, Peoples R China
关键词
water sensitivity; CT scanning; histogram; microscopic mechanism;
D O I
10.1615/.2015013018
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
During the design of an oilfield development plan, reservoir sensitivity must be considered since it will be related to the damage of formation and the change of field output. Traditionally, reservoir sensitivity is evaluated in laboratory by monitoring the change of core permeability through different types of flow experiments. This method can only reflect the macroscopic phenomena, such as pressure and production changes. However, some detailed information cannot be recognized well, like the positions in the core where the formation damage occurred or the microscopic mechanisms involved in that. In this paper, a new method is introduced in characterization and microscopic analysis of water sensitivity by the aid of computerized tomography (CT) scanning technology. Three formation core samples drilled from the same layer were used for waterflooding, gasflooding, and "designing waterflooding" experiments. Significant water sensitivity was implied by comparing the waterflooding with gasflooding experiment results. A "designing waterflooding" experiment with two new variables, virtual porosity and relative porosity, is proposed to investigate the details of water sensitivity. It can be deduced from the experimental results that the formation damage occurred only near the inlet end where the average porosity decreased by 10% to 15%. Porosity reduction of large pore area was relatively higher than that of small pore area by comparing the initial porosity histogram with the final virtual porosity histogram. Microscopic understanding of water sensitivity can be explained that new materials were produced by the reaction between brine and clay minerals, which led to a larger scale of porosity reduction and CT number reduction.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [31] The evaluation of the angles of Eustachian tubes in the patients with chronic otitis media on the temporal computerized tomography
    Aksoy, S.
    Sayin, I.
    Yazici, Z. M.
    Kayhan, F. T.
    Karahasanoglu, A.
    Hocaoglu, E.
    Inci, E.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2016, 19 (03) : 318 - 322
  • [32] Water profile determination in coarse porous media in an experimental channel
    Soualmia, Amel
    Jouini, Manel
    Masbernat, Lucien
    Dartus, Denis
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 2017, (05): : 64 - 68
  • [33] EXPERIMENTAL STUDY OF CIRCULATION OF SATURATING WATER IN ARTIFICIAL POROUS MEDIA
    COURAU, M
    ANNALES AGRONOMIQUES, 1969, 20 (01): : 5 - &
  • [34] SURGICAL-TREATMENT OF SINGLE BRAIN METASTASIS - EVALUATION OF RESULTS BY COMPUTERIZED-TOMOGRAPHY SCANNING
    GALICICH, JH
    SUNDARESAN, N
    THALER, HT
    JOURNAL OF NEUROSURGERY, 1980, 53 (01) : 63 - 67
  • [35] Experimental investigation of solute transport in variably saturated porous media using x-ray computed tomography
    Zhang, Chunwei
    She, Yun
    Hu, Yingxue
    Li, Zijing
    Wang, Weicen
    Patmonoaji, Anindityo
    Suekane, Tetsuya
    PHYSICS OF FLUIDS, 2021, 33 (07)
  • [36] Pharynx and oesophagus evaluation during the swallow using helical computerized tomography
    Takehara, I
    Chu, J
    DISABILITY AND REHABILITATION, 2004, 26 (12) : 733 - 738
  • [37] Pharynx and esophagus evaluation during the swallow using helical computerized tomography
    Takehara, I
    PROCEEDINGS OF THE 2ND WORLD CONGRESS OF THE INTERNATIONAL SOCIETY OF PHYSICAL AND REHABILITATION MEDICINE - ISPRM, 2003, : 743 - 746
  • [38] Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
    Lukats, Olga
    Bujtar, Peter
    Sandor, George K.
    Barabas, Jozsef
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2012, 2012
  • [39] A TECHNIQUE FOR EVALUATION OF VENTRICULAR SHUNTS USING AMIPAQUE AND COMPUTERIZED-TOMOGRAPHY
    FARIA, MA
    OBRIEN, MS
    TINDALL, GT
    JOURNAL OF NEUROSURGERY, 1980, 53 (01) : 92 - 96
  • [40] Evaluation of the human airway using cone-beam computerized tomography
    Tso, Hung Hsiag
    Lee, Janice S.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David
    Miller, Arthur J.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (05): : 768 - 776