MEASUREMENT OF GRIP STRENGTH - VALIDITY AND RELIABILITY OF THE SPHYGMOMANOMETER AND JAMAR GRIP DYNAMOMETER

被引:177
|
作者
HAMILTON, GF
MCDONALD, C
CHENIER, TC
机构
[1] Department of Physical Therapy, School of Allied Health Sciences, East Carolina University, Greenville
来源
关键词
GRIP STRENGTH; HAND INJURY; RELIABILITY;
D O I
10.2519/jospt.1992.16.5.215
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Quantitative measurement of grip strength is an important variable when plotting the progress of a hand-injured patient. When utilizing traditional commercially available apparatuses, obtaining meaningful grip strength measurement in these subjects is frequently difficult due to severe deformity, high tissue sensitivity, and low levels of force generated. The purpose of this study was to measure hand grip strength using two instruments having different physical characteristics and units of measurement to determine the reliability of repeated measures with each instrument. Additionally, validity of the sphygmomanometer for strength measurement was established through comparison with the values obtained from measurements using the research-validated Jamar dynamometer. Twenty-nine right hand dominant female college-age subjects volunteered to perform hand grip strength testing. Measurements were taken with a sphygmomanometer and a Jamar dynamometer while utilizing standardized measurement procedures. A Spearman Rho correlation coefficient test utilized in measuring within-instrument reliability showed a high correlation for each instrument at .85 for the sphygmomanometer and.82 for the Jamar dynamometer. Construct validity testing performed to determine validity of the measurements by the sphygmomanometer compared with the Jamar dynamometer produced a .75 correlation. A formula for conversion of the sphygmomanometer scores into Jamar units was developed to enhance reporting of sphygmomanometer scores utilizing the Jamar standard. The study showed that the sphygmomanometer and Jamar dynamometer exhibit good within-instrument reliability. Validity of the sphygmomanometer as a grip measurement device is acceptable and reportable using the conversion formula developed. Therefore, it can be utilized with confidence as essentially equal to the Jamar unit for grip strength measurement.
引用
收藏
页码:215 / 219
页数:5
相关论文
共 50 条
  • [41] Reference Values of Grip Strength Measured with a Jamar Dynamometer in 1526 Adults with Intellectual Disabilities and Compared to Adults without Intellectual Disability
    Cuesta-Vargas, Antonio
    Hilgenkamp, Thessa
    [J]. PLOS ONE, 2015, 10 (06):
  • [42] Visual Feedback and Weight Reduction of a Grip Strength Dynamometer Do Not Increase Reliability in Healthy Children
    Molenaar, H. M.
    de Kraker, Marjolein
    Zuidam, J. Michiel
    Hovius, Steven E. R.
    Stam, Henk J.
    Selles, Ruud W.
    [J]. JOURNAL OF HAND THERAPY, 2010, 23 (03) : 272 - 279
  • [43] GRIP STRENGTH AND HAND POSITION OF THE DYNAMOMETER IN 204 FINNISH ADULTS
    HARKONEN, R
    PIIRTOMAA, M
    ALARANTA, H
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (01): : 129 - 132
  • [44] COMPARISON OF STOELTING HAND GRIP DYNAMOMETER AND LINEAR VOLTAGE DIFFERENTIAL TRANSFORMER FOR MEASURING MAXIMAL GRIP STRENGTH
    HEYWARD, V
    MCKEOWN, B
    GEESEMAN, R
    [J]. RESEARCH QUARTERLY, 1975, 46 (02): : 262 - 266
  • [45] EFFECT OF VARIATIONS IN HAND GRIP ON RECORDED DYNAMOMETER BACK STRENGTH
    HINOJOSA, R
    BERGER, RA
    [J]. RESEARCH QUARTERLY, 1965, 36 (03): : 366 - 367
  • [46] Electronic Hand Grip Dynamometer
    Kudrna, Petr
    Tejkl, Leos
    Rozanek, Martin
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 249 - 252
  • [47] Estimation of grip force using the Grip-ball dynamometer
    Chkeir, Aly
    Jaber, Rana
    Hewson, David J.
    Duchene, Jacques
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (11) : 1698 - 1702
  • [48] MEASURING GRIP STRENGTH IN CHILDREN WITH THE MARTIN VIGORIMETER AND ADAPTED SPHYGMOMANOMETER CUFF
    GIANNINI, EH
    STILLMAN, CM
    BREWER, EJ
    [J]. OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1984, 4 (03): : 234 - 236
  • [49] Bedside Hand Grip Assessment with the Sphygmomanometer
    Denby, Kara
    Nelson, George
    Estrada, Carlos A.
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 2013, 28 (10) : 1381 - 1381
  • [50] Design and validation of the Grip-ball for measurement of hand grip strength
    Jaber, Rana
    Hewson, David J.
    Duchene, Jacques