COMPARISON OF 2 EXPERIMENTAL METHODS FOR THE DETERMINATION OF MICHAELIS-MENTEN KINETICS OF AN IMMOBILIZED ENZYME

被引:8
|
作者
HOOIJMANS, CM [1 ]
STOOP, ML [1 ]
BOON, M [1 ]
LUYBEN, KCAM [1 ]
机构
[1] DELFT UNIV TECHNOL,DEPT BIOCHEM ENGN,2628 BC DELFT,NETHERLANDS
关键词
MICHAELIS-MENTEN KINETICS; BIOCATALYST PARTICLES; OXYGEN MICROSENSOR; INTRINSIC KINETICS; MODELING;
D O I
10.1002/bit.260400104
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
For the application of immobilized enzymes, the influence of immobilization on the activity of the enzyme should be known. This influence can be obtained by determining the intrinsic kinetic parameters of the immobilized enzyme, and by comparing them with the kinetic parameters of the suspended enzyme. This article deals with the determination of the intrinsic kinetic parameters of an agarose-gel bead immobilized oxygen-consuming enzyme: L-lactate 2-monooxygenase. The reaction rate of the enzyme can be described by Michaelis-Menten kinetics. Batch conversion experiments using a biological oxygen monitor, as well as steady-state profile measurements within the biocatalyst particles using an oxygen microsensor, were performed. Two different mathematical methods were used for the batch conversion experiments, both assuming a pseudo-steady-state situation with respect to the shape of the profile inside the bead. One of the methods used an approximate relation for the effectiveness factor for Michaelis-Menten kinetics which interpolates between the analytical solutions for zero- and first-order kinetics. The other mathematical method was based on a numerical solution and combined a mass balance over the reactor with a mass balance over the bead. The main difference in the application of the two methods is the computer calculation time; the completely numerical calculation procedure was about 20 times slower than the other calculation procedure. The intrinsic kinetic parameters resulting from both experimental methods were compared to check the reliability of the methods. There was no significant difference in the intrinsic kinetic parameters obtained from the two experimental methods. By comparison of the kinetic parameters for the suspended enzyme with the intrinsic kinetic parameters for the immobilized enzyme, it appeared that immobilization caused a decrease in the value of V(m) by a factor of 2, but there was no significant difference in the values obtained for K(m).
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [31] Standardization of α-L-iduronidase enzyme assay with Michaelis-Menten kinetics
    Ou, Li
    Herzog, Tyler L.
    Wilmot, Carrie M.
    Whitley, Chester B.
    [J]. MOLECULAR GENETICS AND METABOLISM, 2014, 111 (02) : 113 - 115
  • [32] Introducing Michaelis-Menten kinetics through simulation
    Halkides, Christopher J.
    Herman, Russell
    [J]. JOURNAL OF CHEMICAL EDUCATION, 2007, 84 (03) : 434 - 437
  • [33] TIME CORRECTION FOR COMPUTING MICHAELIS-MENTEN KINETICS
    RODRIGUEZ, F
    PRATS, M
    [J]. COMPUTER APPLICATIONS IN THE BIOSCIENCES, 1992, 8 (06): : 575 - 577
  • [34] THE EFFECT OF ENZYME CONCENTRATION ON THE MICHAELIS-MENTEN EQUATION
    CHAPLIN, MF
    [J]. TRENDS IN BIOCHEMICAL SCIENCES, 1981, 6 (01) : R6 - R6
  • [35] A SUITABLE PARAMETERIZATION OF THE MICHAELIS-MENTEN ENZYME REACTION
    RATKOWSKY, DA
    [J]. BIOCHEMICAL JOURNAL, 1986, 240 (02) : 357 - 360
  • [36] Comparison of Michaelis-Menten kinetics modeling alternatives in cancer chemotherapy modeling
    Drexler, Daniel Andras
    Ferenci, Tamas
    Lovrics, Anna
    Kovacs, Levente
    [J]. IEEE 13TH INTERNATIONAL SYMPOSIUM ON APPLIED COMPUTATIONAL INTELLIGENCE AND INFORMATICS (SACI 2019), 2019, : 27 - 32
  • [37] Extensions to Michaelis-Menten Kinetics for Single Parameters
    Ariyawansha, R. T. K.
    Basnayake, B. F. A.
    Karunarathna, A. K.
    Mowjood, M. I. M.
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [38] DEVIATION FROM MICHAELIS-MENTEN KINETICS FOR FUMARASE
    CRABBE, MJC
    BARDSLEY, WG
    [J]. BIOCHEMICAL JOURNAL, 1976, 157 (02) : 333 - 337
  • [39] MICHAELIS-MENTEN KINETICS OF STIRIPENTOL IN NORMAL HUMANS
    LEVY, RH
    LOISEAU, P
    GUYOT, M
    BLEHAUT, HM
    TOR, J
    MORELAND, TA
    [J]. EPILEPSIA, 1984, 25 (04) : 486 - 491
  • [40] EXPRESSION OF MICHAELIS-MENTEN KINETICS IN A RADIOTRACER ASSAY
    DOWSE, CM
    LANDMAN, AD
    MASON, P
    [J]. ENZYME, 1977, 22 (02) : 137 - 140