QUANTITATIVE-DETERMINATION OF SI, AL, TI, AND FE IN LATERITES AND BAUXITES BY X-RAY-FLUORESCENCE USING A COMPUTER FOR CORRECTION OF INTERELEMENT EFFECTS

被引:2
|
作者
SCHORIN, H
机构
关键词
FLUORESCENCE;
D O I
10.1366/0003702794925147
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A method for the quantitative determination of the major constituents in laterites and bauxites by x-ray fluorescence using fused Na//2B//4O//7 glass discs is presented. The calibration curves were set up employing synthetic mixtures of oxides of Si, Al, Ti, and Fe. The interelement effects were corrected using a multiple regression analysis programed on a PDP 11/45 computer. The precision was determined by preparation and analysis of five synthetic pellets; the accuracy was ascertained by analysis of five international standards.
引用
收藏
页码:634 / 637
页数:4
相关论文
共 46 条
  • [31] A QUANTITATIVE X-RAY FLUORESCENCE METHOD OF ANALYSIS FOR GEOLOGICAL SAMPLES USING A CORRECTION TECHNIQUE FOR MATRIX EFFECTS
    STRASHEIM, A
    BRANDT, MP
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1967, B 23 (03) : 183 - +
  • [32] Quantitative analysis of elements (C,N,O,Al,Si and Fe) in polyamide with wavelength dispersive X-ray fluorescence spectrometry
    LAI MeiShuang
    XIANG LeiWen
    LIN Jin-Ming
    LI Hai-Fang
    Science China(Chemistry), 2013, (08) : 1164 - 1170
  • [33] Quantitative analysis of elements (C, N, O, Al, Si and Fe) in polyamide with wavelength dispersive X-ray fluorescence spectrometry
    Lai MeiShuang
    Xiang LeiWen
    Lin Jin-Ming
    Li Hai-Fang
    SCIENCE CHINA-CHEMISTRY, 2013, 56 (08) : 1164 - 1170
  • [34] Quantitative analysis of elements (C, N, O, Al, Si and Fe) in polyamide with wavelength dispersive X-ray fluorescence spectrometry
    MeiShuang Lai
    LeiWen Xiang
    Jin-Ming Lin
    Hai-Fang Li
    Science China Chemistry, 2013, 56 : 1164 - 1170
  • [35] Quantitative analysis of elements (C,N,O,Al,Si and Fe) in polyamide with wavelength dispersive X-ray fluorescence spectrometry
    LAI MeiShuang
    XIANG LeiWen
    LIN JinMing
    LI HaiFang
    Science China(Chemistry), 2013, 56 (08) : 1164 - 1170
  • [36] DETERMINATION OF HIGH-CONCENTRATIONS OF ELEMENTS IN MULTI-ELEMENT SOLUTIONS BY X-RAY-FLUORESCENCE SPECTROMETRY USING A SPIKING-MATHEMATICAL CORRECTION TECHNIQUE
    ZIMMERMAN, JB
    INGLES, JC
    CANADIAN JOURNAL OF SPECTROSCOPY, 1972, 17 (05): : 156 - 163
  • [37] USE OF INCOHERENT SCATTERING FOR MATRIX EFFECTS CORRECTION IN X-RAY FLUORESCENCE MEASUREMENTS OF Ti, Mn, Fe AND U CONCENTRATIONS IN URANIUM ORES
    Kutnii, D. V.
    Medvediev, A. V.
    Vanzha, S. A.
    EAST EUROPEAN JOURNAL OF PHYSICS, 2016, 3 (02): : 41 - 48
  • [38] X-RAY FLUOTESCENCE ANALYSIS OF FE, TI, CA, K, SI AND AL IN SILICATE ROCKS USING GLASS DISCS OF LITHIUM BORATE
    EMMERMANN, R
    OBI, DVC
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1971, 254 (01): : 1 - +
  • [39] APPLICATION OF A CURVE-FITTING COMPUTER-PROGRAM TO COMPENSATE FOR INTER-ELEMENT EFFECTS IN X-RAY-FLUORESCENCE ANALYSIS OF ROCK SAMPLES - DETERMINATION OF VANADIUM IN GEOLOGICAL STANDARDS
    RIDDLE, C
    SMITH, TE
    X-RAY SPECTROMETRY, 1977, 6 (01) : 18 - 20
  • [40] EXTRACTION OF METAL-IONS CR(III), FE(III), CO(II), NI(II), AND ZN(II) WITH MOLTENTOXINE AND DETERMINATION OF EXTRACTED METALS USING X-RAY-FLUORESCENCE
    MAGYAR, B
    LOBANOV, FI
    TALANTA, 1973, 20 (01) : 55 - 63