REGISTRATION OF THE THERMAL NEUTRONS USING UNCOOLED Si PLANAR DETECTOR

被引:0
|
作者
Bochek, G. L. [1 ]
Deiev, O. S. [1 ]
Kiprich, S. K. [1 ]
Maslov, N. I. [1 ]
Shulika, M. Y. [1 ]
Vasiliev, G. P. [1 ]
Yalovenko, V. I. [1 ]
机构
[1] Natl Sci Ctr, Kharkov Inst Phys & Technol, Kharkov, Ukraine
关键词
D O I
暂无
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The registration of thermal neutrons by Si planar detector with natural metallic Gd neutron converter was performed. The Pu-239-Be(alpha, n) fast neutron source with flux 1.13.10(5) c(-1) with paraffin moderator for obtaining of thermal neutrons was used. Control measurements of the thermal neutron flux by detector-dosimeter MKS-01R were performed. Experimental spectra for the reaction Gd(n, gamma) Gd were measured. Spectra consisted of the spectra conversion electrons in energy range 30...200 keV with maximum at energy similar to 70 keV and Gd CXR lines. Background gamma-radiation was measured by Si PIN detector without Gd plate. Program code GEANT4 for the calculation of the thermal neutron flux was used.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [21] A comment on the reported detectivity of a new uncooled thermal infrared detector
    Brasunas, JC
    Lakew, B
    Fettig, R
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2002, 96 (2-3) : 211 - 213
  • [22] A scintillation strip detector for detection of thermal neutrons
    Peresedov, V. F.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (05) : 629 - 636
  • [23] SI DIODE AS A SMALL DETECTOR OF SLOW-NEUTRONS
    POSPISIL, S
    SOPKO, B
    HAVRANKOVA, E
    JANOUT, Z
    KONICEK, J
    MACHA, I
    PAVLU, J
    [J]. RADIATION PROTECTION DOSIMETRY, 1993, 46 (02) : 115 - 118
  • [24] Modeling the registration efficiency of thermal neutrons by gadolinium foils
    Abdushukurov, D.A.
    Abduvokhldov, M.A.
    Bondarenko, D.V.
    Mumlnov, Kh.Kh.
    Toshov, T.A.
    Chlstyakov, D.Yu.
    [J]. Journal of Instrumentation, 2007, 2
  • [25] Optimization of the Structure of a Heterogeneous Scintillator for Registration of Thermal Neutrons
    Kuzmin, E. S.
    Zimin, I. Yu
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2021, 64 (05) : 657 - 662
  • [26] Optimization of the Structure of a Heterogeneous Scintillator for Registration of Thermal Neutrons
    E. S. Kuzmin
    I. Yu. Zimin
    [J]. Instruments and Experimental Techniques, 2021, 64 : 657 - 662
  • [27] Modeling the registration efficiency of thermal neutrons by gadolinium foils
    Abdushukurov, D. A.
    Abduvokhidov, M. A.
    Bondarenko, D. V.
    Muminov, Kh. Kh.
    Toshov, T. A.
    Chistyakov, D. Yu.
    [J]. JOURNAL OF INSTRUMENTATION, 2007, 2
  • [28] A novel detector assembly for detecting thermal neutrons, fast neutrons and gamma rays
    Cester, D.
    Lunardon, M.
    Moretto, S.
    Nebbia, G.
    Pino, F.
    Sajo-Bohus, L.
    Stevanato, L.
    Bonesso, I.
    Turato, F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 830 : 191 - 196
  • [29] AN UNCOOLED FIR DETECTOR USING THE AVALANCHE INJECTION EFFECT
    KIKUCHI, K
    [J]. INFRARED PHYSICS & TECHNOLOGY, 1994, 35 (01) : 33 - 39
  • [30] Determination of thermal parameters of vanadium oxide uncooled microbolometer infrared detector
    Kumar, RTR
    Karunagaran, B
    Mangalaraj, D
    Narayandass, SK
    Manoravi, P
    Joseph, M
    Gopal, V
    Madaria, RK
    Singh, JP
    [J]. INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2003, 24 (03): : 327 - 334