PITFALLS IN THE USE OF CO-57 FLOOD SOURCES

被引:0
|
作者
SOKOLE, EB
KUGI, A
BERGMANN, H
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Long-lived Co-57 flood sources, used for routine quantitative monitoring of scintillation camera hood-held uniformity, have recently become available with nominal activities of 370 MBq and higher. Non-uniformity problems have been observed. These are presumably related to high overall count rates from Co-57 and other radioactive cobalt isotopes present as impurities. This was investigated in five different cameras from four manufacturers using three cobalt sources of different ages and strengths. Count rates were measured within the energy range 30 keV to 1200 keV, and compared to the count rates in the 122 keV photopeak window. For a new flood source placed on the collimator, the overall count rate was about 400% of the photopeak window count rate. About 200% was due to high energy photons with energies above 134 keV. The count rate diminished when the source was moved away to a distance of 50 cm. The high energy contribution was less with the older sources, due to the faster decay of the cobalt impurities. Uniformity images were visually and quantitatively evaluated. Non-uniformity patterns were observed. These were dependent on the actual source area viewed by the camera, the age of the source, the distance of the source from the collimator, and the type of camera. Problems can be circumvented by purchasing lower activity sources (180 MBq), and increasing the source-collimator distance. Uniformity must first be carefully assessed before the source is put into use.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [41] ACCURATE EXCITATION-ENERGIES OF CO-57
    BIESZK, JA
    ROLLEFSO.AA
    GOSS, JD
    BROWNE, CP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (01): : 90 - 90
  • [42] CO-57 EMISSION STUDIES OF CUPRIC OXIDE
    BARCS, A
    BOTTYAN, L
    MOLNAR, B
    NAGY, DL
    OVANESYAN, NS
    SPIERING, H
    HYPERFINE INTERACTIONS, 1990, 55 (1-4): : 1187 - 1193
  • [43] THE CO-57 ABUNDANCE IN SN-1987A
    CLAYTON, DD
    LEISING, MD
    THE, LS
    JOHNSON, WN
    KURFESS, JD
    ASTROPHYSICAL JOURNAL, 1992, 399 (02): : L141 - L144
  • [44] SEARCH FOR ANALOG RESONANCES IN CO-57(I)
    ELKATEB, S
    GRIFFITHS, GM
    NUCLEAR PHYSICS A, 1975, A240 (01) : 120 - 136
  • [45] PREPARATION OF RADIOACTIVE LABELED CO-57 SULFITOCOBALAMIN
    BEGLEY, JA
    HORCH, C
    HALL, CA
    PREPARATIVE BIOCHEMISTRY, 1978, 8 (06): : 411 - 419
  • [46] ELECTRODEPOSITION OF COBALT ON STAINLESS-STEEL FOILS - PREPARATION OF CO-57 SOURCES FOR MOSSBAUER EXPERIMENTS
    GONZALEZRAMIREZ, R
    JIMENEZDOMINGUEZ, H
    SOLORZAFERIA, O
    ORDONEZREGIL, E
    CABRALPRIETO, A
    BULBULIAN, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 174 (02): : 291 - 298
  • [47] LABELING OF SERUM-ALBUMIN WITH CO-57
    MALCOLMELAWES, DJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (03): : 190 - 191
  • [48] SIDEBAND AND QUANTUM-BEAT MEASUREMENTS WITH TE-129M AND CO-57 SOURCES
    VANVOORTHUYSEN, EHD
    ZHANG, GL
    DEWAARD, H
    HYPERFINE INTERACTIONS, 1983, 16 (1-4): : 1025 - 1028
  • [49] DETERMINATION OF CO-57 HYPERFINE FIELD IN PD(CO-57) FROM MOSSBAUER EMISSION-SPECTRA IN REGIME OF FAST RELAXATION
    AFANASEV, AM
    LITTERST, FJ
    GIERISCH, W
    JOURNAL DE PHYSIQUE LETTRES, 1978, 39 (12): : L183 - L186
  • [50] EXCITED LEVELS IN CO-57 FROM DECAY OF NI-57
    CHILOSI, G
    MONARO, S
    RICCI, RA
    NUOVO CIMENTO, 1962, 26 (03): : 440 - +