EVALUATION OF THE USE OF FREE AND IMMOBILIZED ACETYLCHOLINESTERASE FOR PARAOXON DETECTION WITH AN AMPEROMETRIC CHOLINE OXIDASE BASED BIOSENSOR

被引:111
|
作者
CREMISINI, C
DISARIO, S
MELA, J
PILLOTON, R
PALLESCHI, G
机构
[1] ENEA,CRE CASACCIA,DEPT NEW TECHNOL,BIOTECH & AGR SECTOR,I-00060 ROME,ITALY
[2] UNIV ROMA TOR VERGATA,I-00173 ROME,ITALY
关键词
BIOSENSORS; AMPEROMETRY; PESTICIDES; ACETYLCHOLINESTERASE; PARAOXON;
D O I
10.1016/0003-2670(94)00618-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aspects related to the use of free and immobilised acetylcholinesterase (AChE) for the development of an amperometric biosensor for organophosphorus (OF) insecticides based on enzyme inhibition have been studied. Procedures based on free and immobilised AChE were previously studied from many authors but the measurement of the residual enzyme activity has been directly carried out in the same sample where incubation of AChE with OP has been performed. With AChE immobilised on a nylon net and not assembled on the sensor it is possible to perform incubation and measurement steps separately: the incubation step is performed in the sample containing the inhibitor, the measurement step is performed in a standard solution containing the specific substrate in the buffer. With this two-step procedure, a Pt electrode, only covered with a thin layer of cross-linked choline oxidase and without any membrane, has also been used in batch conditions obtaining interesting results in terms of sensitivity, precision and limit of detection.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 50 条
  • [21] Determination of choline in milk, milk powder, and soy lecithin hydrolysates by flow injection analysis and amperometric detection with a choline oxidase based biosensor
    Pati, S
    Quinto, M
    Palmisano, F
    Zambonin, PG
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (15) : 4638 - 4642
  • [22] Construction of an acetylcholinesterase-choline oxidase biosensor for aldicarb determination
    Kök, FN
    Bozoglu, F
    Hasirci, V
    NOVEL PROCESSES AND CONTROL TECHNOLOGIES IN THE FOOD INDUSTRY, 2001, 338 : 49 - 62
  • [23] Construction of an acetylcholinesterase-choline oxidase biosensor for aldicarb determination
    Kok, FN
    Bozoglu, F
    Hasirci, V
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7): : 531 - 539
  • [24] Immobilization of acetylcholinesterase and choline oxidase in/on pHEMA membrane for biosensor construction
    Kok, FN
    Bozoglu, F
    Hasirci, V
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2001, 12 (11) : 1161 - 1176
  • [25] Flow injection analysis of paraoxon with the use of an immobilized acetylcholinesterase reactor
    Shi, RB
    Stein, K
    ANALYTICA CHIMICA ACTA, 1996, 324 (01) : 21 - 27
  • [26] Disposable amperometric acetylcholinesterase biosensor for the detection of organophosphorus pesticides
    Wang, Xiaohao
    Xu, Xiaowen
    Tang, Fei
    Zhou, Zhaoying
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 333 - 336
  • [27] A new amperometric acetylcholinesterase biosensor for the detection of organophosphorus pesticides
    Xu, XW
    Wang, XH
    Tang, F
    ISTM/2005: 6TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-9, CONFERENCE PROCEEDINGS, 2005, : 3727 - 3729
  • [28] Disposable Amperometric Acetylcholinesterase Biosensor for the Detection of Organophosphorus Pesticides
    Xiaohao Wang Xiaowen Xu Fei Tang Zhaoying Zhou (State Key Laboratory of Precision Measurement Technology and Instruments
    稀有金属材料与工程, 2006, (S3) : 333 - 336
  • [29] Computational modeling of amperometric choline biosensor for neurochemical detection
    Ravikumar, P.
    Arumugam, S.
    Jeyashanthi, N.
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (04): : 1271 - 1274
  • [30] Optimisation of the amperometric acetylcholinesterase based micro-biosensor for the detection of organophosphorus pesticides
    Turdean, G
    Popescu, IC
    Oniciu, L
    Thevenot, DR
    PROCEEDINGS OF THE SYMPOSIUM ON CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL ELECTROCHEMICAL METHODS, 1997, 97 (19): : 966 - 968