A HIGH-FREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPH USING DISTRIBUTED PARALLEL INPUT CHANNELS

被引:0
|
作者
JOSSINET, J [1 ]
TRILLAUD, C [1 ]
RISACHER, F [1 ]
MCADAMS, ET [1 ]
机构
[1] UNIV ULSTER,NIBEC,JORDANSTOWN BT37 0QB,ANTRIM,NORTH IRELAND
关键词
ELECTRICAL BIOIMPEDANCE; ELECTRICAL IMPEDANCE TOMOGRAPHY; TISSUE CHARACTERIZATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrical Impedance Tomography (EIT) is an imaging technique based on multiple impedance measurements using electronically multiplexed surface electrodes. The present study describes an EIT prototype tomograph which uses two frequencies of applied signal: 31.25 kHz (within the frequency range originally used in early EIT studies) and 250 kHz. The use of the latter frequency was made possible as a result of several technical innovations including the use of separate groups of electrodes for current injection and for differential voltage measurement and the use of parallel input channels distributed around the object. In vitro images were successfully obtained using the system at the above two frequencies. It is concluded from this study that Electrical Impedance Tomography can be used at sufficiently high frequencies to enable bio-electrical tissue characterisation.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [31] High-frequency impedance meter
    Bateman, C
    [J]. ELECTRONICS WORLD, 2001, 107 (1777): : 24 - 30
  • [32] THE FREQUENCY-DEPENDENT RESPONSE OF THE ELECTRICAL-IMPEDANCE OF UO2
    HAMPTON, RN
    SAUNDERS, GA
    STONEHAM, AM
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1986, 139 (03) : 185 - 190
  • [33] Resonant impedance and effective series resistance of high-frequency parallel resonant circuits
    Iinuma, H
    [J]. PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1931, 19 (03): : 0467 - 0478
  • [34] High-frequency respiratory input impedance measurements in infants assessed by the high speed interrupter technique
    Frey, U
    Silverman, M
    Kraemer, R
    Jackson, AC
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (01) : 148 - 158
  • [35] The simulation of current generator design for multi-frequency electrical impedance tomograph
    Chen, Cheng-Yu
    Lu, Yi-Yu
    Huang, Wen-Lung
    Cheng, Kuo-Shang
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 974 - +
  • [36] BLOOD-FLOW IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BROWN, BH
    LEATHARD, A
    SINTON, A
    MCARDLE, FJ
    SMITH, RWM
    BARBER, DC
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 175 - 179
  • [37] Improving High-Frequency Performance of an Input Common Mode EMI Filter Using an Impedance-Mismatching Filter
    Luo, Fang
    Dong, Dong
    Boroyevich, Dushan
    Mattavelli, Paolo
    Wang, Shuo
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (10) : 5111 - 5115
  • [38] An Evaluation Method for Electrical Contact Failure Based on High-Frequency Impedance Model
    Zhang, Gang
    Zhang, Linzhi
    Li, Ming
    He, Xin
    Li, Ling
    Duan, Mengda
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2021, 11 (04): : 579 - 588
  • [39] High-frequency input impedance characterization of dielectric films for power-ground planes
    Obrzut, J
    Anopchenko, A
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (04) : 1120 - 1124
  • [40] HIGH-FREQUENCY INPUT IMPEDANCE OF DRIED DOG LUNGS - MODELING WITH BRANCHING AIRWAY NETWORKS
    JACKSON, AC
    SUKI, B
    HABIB, RH
    UCAR, M
    LUTCHEN, KR
    [J]. FASEB JOURNAL, 1992, 6 (05): : A1806 - A1806