A HIGH-FREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPH USING DISTRIBUTED PARALLEL INPUT CHANNELS

被引:0
|
作者
JOSSINET, J [1 ]
TRILLAUD, C [1 ]
RISACHER, F [1 ]
MCADAMS, ET [1 ]
机构
[1] UNIV ULSTER,NIBEC,JORDANSTOWN BT37 0QB,ANTRIM,NORTH IRELAND
关键词
ELECTRICAL BIOIMPEDANCE; ELECTRICAL IMPEDANCE TOMOGRAPHY; TISSUE CHARACTERIZATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrical Impedance Tomography (EIT) is an imaging technique based on multiple impedance measurements using electronically multiplexed surface electrodes. The present study describes an EIT prototype tomograph which uses two frequencies of applied signal: 31.25 kHz (within the frequency range originally used in early EIT studies) and 250 kHz. The use of the latter frequency was made possible as a result of several technical innovations including the use of separate groups of electrodes for current injection and for differential voltage measurement and the use of parallel input channels distributed around the object. In vitro images were successfully obtained using the system at the above two frequencies. It is concluded from this study that Electrical Impedance Tomography can be used at sufficiently high frequencies to enable bio-electrical tissue characterisation.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [1] AN ELECTRICAL-IMPEDANCE TOMOGRAPH USING COMPOUND ELECTRODES
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    [J]. IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 472 - 473
  • [2] ELECTRICAL SAFETY FOR AN ELECTRICAL-IMPEDANCE TOMOGRAPH
    GHAHARY, A
    WEBSTER, JG
    [J]. IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 461 - 462
  • [3] RESOLUTION PERFORMANCE OF AN ELECTRICAL-IMPEDANCE TOMOGRAPH
    BOULAY, C
    GUARDO, R
    MURRAY, B
    BERTRAND, M
    [J]. IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 470 - 471
  • [4] DESIGN AND EVALUATION OF AN ELECTRICAL-IMPEDANCE TOMOGRAPH
    GUARDO, R
    BOULAY, C
    MURRAY, B
    BERTRAND, M
    [J]. CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY CONFERENCE : PROCEEDINGS - 1989, 1989, : 19 - 20
  • [5] A REAL-TIME ELECTRICAL-IMPEDANCE TOMOGRAPH
    EDIC, PM
    SAULNIER, GJ
    NEWELL, JC
    ISAACSON, D
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (09) : 849 - 859
  • [6] ACT3 - A HIGH-SPEED, HIGH-PRECISION ELECTRICAL-IMPEDANCE TOMOGRAPH
    COOK, RD
    SAULNIER, GJ
    GISSER, DG
    GOBLE, JC
    NEWELL, JC
    ISAACSON, D
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (08) : 713 - 722
  • [7] RELATION BETWEEN HIGH-FREQUENCY ELECTRICAL-IMPEDANCE AND MALIGNITY OF 2 L-CELL SUBLINES
    SETKA, J
    MANDYS, V
    VRANA, J
    HOLECKOVA, E
    [J]. NEOPLASMA, 1986, 33 (05) : 609 - 613
  • [8] NOISE AND SPATIAL-RESOLUTION OF A REAL-TIME ELECTRICAL-IMPEDANCE TOMOGRAPH
    SINTON, AM
    BROWN, BH
    BARBER, DC
    MCARDLE, FJ
    LEATHARD, AD
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 125 - 130
  • [9] FREQUENCY-CHARACTERISTICS OF THE ELECTRICAL-IMPEDANCE OF LEGS
    SAKAMOTO, K
    KANAI, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 954 - 954
  • [10] INPUT IMPEDANCE OF THE RF SQUID IN HIGH-FREQUENCY REGIME
    TINCHEV, SS