The magnet, weighing 10 tons, is part of a whole-body magnetic resonance imaging (MRI) device devoted to in vivo research studies at magnetic fields significantly higher than 2 T. The stored energy of the adiabatically stable six-coil system is 39 MJ at 4 T. The rated current is 376 A. Superconducting and resistive shim-coils together with iron shims reduce the bare magnet inhomogeneity of 100 ppm down to less than 5 ppm in a 50-cm diameter spherical volume. The magnet operates in persistent mode with the current leads retracted. The field drift is less than 3 multiplied by 10**-**8/h. A small helium refrigerator is used both to cool the two radiation shields of the cryostat and the current leads and to reliquify the evaporating helium gas. Results of coil design, analysis of forces and stresses, quench protection, cryostat design, and magnet operation are reported.
引用
收藏
页码:1285 / 1287
页数:3
相关论文
共 50 条
  • [21] Diffusion-weighted whole-body MR imaging with background body signal suppression:: a feasibility study at 3.0 Tesla
    Muertz, Petra
    Krautmacher, Carsten
    Traeber, Frank
    Gieseke, Juergen
    Schild, Hans H.
    Willinek, Winfried A.
    EUROPEAN RADIOLOGY, 2007, 17 (12) : 3031 - 3037
  • [22] Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla
    Petra Mürtz
    Carsten Krautmacher
    Frank Träber
    Jürgen Gieseke
    Hans H. Schild
    Winfried A. Willinek
    European Radiology, 2007, 17 : 3031 - 3037
  • [23] Whole-body imaging of the musculoskeletal system: the value of MR imaging
    Schmidt, Gerwin P.
    Reiser, Maximilian F.
    Baur-Melnyk, Andrea
    SKELETAL RADIOLOGY, 2007, 36 (12) : 1109 - 1119
  • [24] Whole-body imaging of the musculoskeletal system: the value of MR imaging
    Gerwin P. Schmidt
    Maximilian F. Reiser
    Andrea Baur-Melnyk
    Skeletal Radiology, 2007, 36 : 1109 - 1119
  • [25] WHOLE-BODY MR IMAGING AND SPECTROSCOPY AT 4-T - WHERE DO WE GO FROM HERE
    ORTENDAHL, DA
    RADIOLOGY, 1988, 169 (03) : 864 - 865
  • [26] Whole-body MR imaging: Evaluation of patients for metastases
    Lauenstein, TC
    Goehde, SC
    Herborn, CU
    Goyen, M
    Oberhoff, C
    Debatin, JF
    Ruehm, SG
    Barkhausen, J
    RADIOLOGY, 2004, 233 (01) : 139 - 148
  • [27] Whole-body MR imaging: The future "X ray"?
    Ko, JSC
    Cheng, HC
    Chang, HY
    Chang, CY
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (03) : 860 - 861
  • [28] Whole-body FSE STIR MR imaging of lymphoma
    El-Hariri, Mona A.
    Gouhar, Ghada K.
    Haggag, Rasha M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2011, 42 (01): : 77 - 85
  • [29] Fast STIR whole-body MR imaging in children
    Kellenberger, CJ
    Epelman, M
    Miller, SF
    Babyn, PS
    RADIOGRAPHICS, 2004, 24 (05) : 1317 - 1330
  • [30] Whole-body MR/PET: applications in abdominal imaging
    N. F. Schwenzer
    H. Schmidt
    C. D. Claussen
    Abdominal Imaging, 2012, 37 : 20 - 28