A CHAMBER AND ELECTROMETER CALIBRATION FACTOR AS DETERMINED BY EACH OF THE 5 AAPM ACCREDITED DOSIMETRY CALIBRATION LABORATORIES

被引:3
|
作者
BLACKWELL, CR
MCCULLOUGH, EC
机构
关键词
D O I
10.1118/1.596880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer factor constancy and showed a maximum deviation of 0.32% (typically less than 0.1%) over the 227 days needed to complete the intercomparison. The chamber and electrometer calibration factor provided by each of the five ADCLs were analyzed for consistency. The maximum percent difference in reported chamber factor between all five ADCLs was 1.40%. The reported electrometer factor had a maximum discrepancy of only 0.50%. System (chamber plus electrometer) factors as provided by three of the five ADCLs had a maximum discrepancy of 1.51%.
引用
收藏
页码:207 / 208
页数:2
相关论文
共 50 条
  • [31] An anthropomorphic body phantom for the determination of calibration factor in radionuclide treatment dosimetry
    Kovan, Bilal
    Demir, Bayram
    Isik, Emine Goknur
    Simsek, Duygu Has
    Ozkan, Zeynep Gozde
    Kuyumcu, Sekan
    Turkmen, Cuneyt
    Sanli, Yasemin
    [J]. RADIATION PROTECTION DOSIMETRY, 2023, 199 (12) : 1274 - 1283
  • [32] Modified calibration protocols in electron beam dosimetry: comparison with IAEA TRS-398 and AAPM TG-51
    Yulinar, Cica
    Assegab, Muhamad Iqbal
    Wibowo, Wahyu Edy
    Pawiro, Supriyanto Ardjo
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (05)
  • [33] A chamber for determining the conventionally true value of Hp(10) and H*(10) needed by calibration laboratories
    Ankerhold, U
    Ambrosi, P
    Eberle, T
    [J]. RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 133 - 137
  • [34] Testing investigation of antenna calibration factor and insertion loss of a reverberation chamber
    Zhang, Bo
    Li, Wei
    [J]. Gaodianya Jishu/High Voltage Engineering, 2010, 36 (03): : 637 - 642
  • [35] Kr-81m calibration factor for the npl ionisation chamber
    Johansson, Lena
    Stroak, Andrew
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1360 - 1364
  • [36] Variability of Gamma Knife Output Calibration Based On Chamber Type, Phantom Material, and Dosimetry Protocol
    Boczkowski, A.
    Graves, S.
    Poplawski, L.
    Hyer, D.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E117 - E117
  • [37] Accuracy of Kilovoltage X-Ray Beam Dosimetry Using a 0.6 Cc Ionization Chamber with An Absorbed Dose to Water Calibration Factor
    Uchida, Y.
    Tachibana, H.
    Kogure, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3121 - 3121
  • [38] The wall correction factor for a spherical ionization chamber used in brachytherapy source calibration
    Piermattei, A
    Azario, L
    Fidanzio, A
    Viola, P
    Dell'Omo, C
    Iadanza, L
    Fusco, V
    Lagares, JI
    Capote, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24): : 4091 - 4103
  • [39] Set-up and calibration of a triple ionization chamber system for dosimetry in mixed neutron/photon fields
    Becker, J.
    Brunckhorst, E.
    Roca, A.
    Stecher-Rasmussen, F.
    Moss, R.
    Boettger, R.
    Schmidt, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13): : 3715 - 3727
  • [40] AAPM TG-61 report on kilovoltage X-ray dosimetry: II. Calibration procedures and correction factors.
    Seuntjens, JP
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2313 - 2316