A CHAMBER AND ELECTROMETER CALIBRATION FACTOR AS DETERMINED BY EACH OF THE 5 AAPM ACCREDITED DOSIMETRY CALIBRATION LABORATORIES

被引:3
|
作者
BLACKWELL, CR
MCCULLOUGH, EC
机构
关键词
D O I
10.1118/1.596880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer factor constancy and showed a maximum deviation of 0.32% (typically less than 0.1%) over the 227 days needed to complete the intercomparison. The chamber and electrometer calibration factor provided by each of the five ADCLs were analyzed for consistency. The maximum percent difference in reported chamber factor between all five ADCLs was 1.40%. The reported electrometer factor had a maximum discrepancy of only 0.50%. System (chamber plus electrometer) factors as provided by three of the five ADCLs had a maximum discrepancy of 1.51%.
引用
收藏
页码:207 / 208
页数:2
相关论文
共 50 条
  • [1] A PERSPECTIVE ON ACCREDITED DOSIMETRY CALIBRATION LABORATORIES
    GOETSCH, SJ
    [J]. HEALTH PHYSICS, 1985, 49 (01): : 174 - 174
  • [2] Uncertainty of calibrations at the accredited dosimetry calibration laboratories
    Ibbott, GS
    Attix, FH
    Slowey, TW
    Fontenla, DP
    Rozenfeld, M
    [J]. MEDICAL PHYSICS, 1997, 24 (08) : 1249 - 1254
  • [3] The US radiation dosimetry standards for 60Co therapy level beams, and the transfer to the AAPM accredited dosimetry calibration laboratories
    Minniti, R
    Chen-Mayer, H
    Seltzer, SM
    Huq, MS
    Bryson, L
    Slowey, T
    Micka, JA
    DeWerd, LA
    Wells, N
    Hanson, WF
    Ibbott, GS
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 1074 - 1077
  • [5] THE UNIVERSITY-OF-WISCONSIN AAPM-ACCREDITED DOSIMETRY CALIBRATION LABORATORY PROCEDURES
    DEWERD, LA
    [J]. HEALTH PHYSICS, 1984, 47 (01): : 158 - 159
  • [6] Comparison of micropipettes calibration by accredited laboratories
    Madec, Tanguy
    Amarouche, Soraya
    [J]. 4th International Metrology Conference 2012, CAFMET 2012, 2017, : 144 - 150
  • [7] Energy fluence calibration of an accredited dosimetry calibration laboratory cobalt 60 beam
    Smilowitz, J
    Jeraj, R
    Olivera, GH
    DeWerd, LA
    Mackie, TR
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1319 - 1319
  • [8] Verification of an automatic calibration process in Italian accredited laboratories
    Cassiago, C
    La Paglia, G
    Pollio, C
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 602 - 603
  • [9] Comparison of pencil-type ionization chamber calibration results and methods between dosimetry laboratories
    Hourdakis, Costas J.
    Bueermann, Ludwig
    Ciraj-Bjelac, Olivera
    Csete, Istvan
    Delis, Harry
    Gomola, Igor
    Persson, Linda
    Novak, Leos
    Petkov, Ivailo
    Toroi, Paula
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 42 - 51
  • [10] The impact of organisational trust on the functioning of Polish accredited testing and calibration laboratories
    Bienkowska, Agnieszka
    Zablocka-Kluczka, Anna
    [J]. ENTERPRISE AND COMPETITIVE ENVIRONMENT, 2017, : 127 - 139