ANALYSIS OF 5-FLUOROURACIL IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:40
|
作者
BARBERIHEYOB, M
MERLIN, JL
WEBER, B
机构
[1] Centre Alexis Vautrin, Laboratoire de Recherche, 54511 Vandoeuvre-Les-Nancy Cedex, Avenue de Bourgogne Brabois
来源
关键词
D O I
10.1016/0378-4347(92)80283-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A relatively simple, sensitive and rapid high-performance liquid chromatographic method is described for measuring the anticancer drug 5-fluorouracil (5-FU) in human plasma and urine. The procedure includes liquid-liquid extraction using ethyl acetate-methanol (95:5) and preparative column chromatography to separate 5-FU from constituents normally occurring in these biological samples. The columns contained a specially modified form of diatomaceous earth, which requires no pre-conditioning washes. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70 mm x 4.6 mm I.D.) with a mobile phase of water-methanol (95:5) and ultraviolet detection (268 nm). The overall recovery from plasma and urine was 91 and 94%, respectively, at the concentration of 50 ng/ml. The determination limit of the assay for 5-FU was 10 ng/ml of plasma and urine. Concentrations of 5-FU between 10 and 500 ng/ml were measured in plasma and urine with a relative standard deviation of 6.8%. In order to evaluate the procedure, plasma and urine samples from three patients treated with 5-FU by continuous intravenous perfusion, were investigated.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [21] ANALYSIS OF RIBOXAMIDE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MELTZER, NM
    STERNSON, LA
    JOURNAL OF CHROMATOGRAPHY, 1984, 307 (01): : 216 - 219
  • [22] THE DETERMINATION OF OXALATE IN URINE AND PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FRY, IDR
    STARKEY, BJ
    ANNALS OF CLINICAL BIOCHEMISTRY, 1991, 28 : 581 - 587
  • [23] MEASUREMENT OF XAMOTEROL IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ODDIE, CJ
    JACKMAN, GP
    BOBIK, A
    JOURNAL OF CHROMATOGRAPHY, 1984, 308 (JUN): : 370 - 375
  • [24] DETERMINATION OF PAPAVERINE IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GAUTAM, SR
    NAHUM, A
    BAECHLER, J
    BOURNE, DWA
    JOURNAL OF CHROMATOGRAPHY, 1980, 182 (3-4): : 482 - 486
  • [25] DETERMINATION OF SACCHARIN IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BEKERSKY, I
    COLBURN, WA
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1980, 13 (10): : 805 - 816
  • [26] DETERMINATION OF VELNACRINE IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HSU, RS
    DILEO, EM
    CHESSON, SM
    ELLIS, DB
    WICHMANN, JK
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 494 : 347 - 353
  • [27] DETERMINATION OF PIRLINDOLE IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OSTROWSKI, J
    THEUMER, J
    GARTNER, W
    RESAG, K
    PASSING, H
    JOURNAL OF CHROMATOGRAPHY, 1984, 309 (01): : 115 - 123
  • [28] DETERMINATION OF CIBENZOLINE IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HACKMAN, MR
    LEE, TL
    BROOKS, MA
    JOURNAL OF CHROMATOGRAPHY, 1983, 273 (02): : 347 - 356
  • [29] AN ASSAY FOR PRIZIDILOL IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PEARCE, JC
    MURKITT, GS
    TAYLOR, DC
    CRESSWELL, PR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1986, 4 (01) : 115 - 121
  • [30] DETERMINATION OF ALCURONIUM IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEBROS, F
    OKUTANI, R
    INADA, E
    LAWRENCE, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 529 (02): : 449 - 454