MORE THAN 10 YEARS FOLLOW-UP OF THE HANCOCK PORCINE BIOPROSTHESIS IN JAPAN

被引:0
|
作者
KAWACHI, Y [1 ]
TANAKA, J [1 ]
TOMINAGA, R [1 ]
KINOSHITA, K [1 ]
TOKUNAGA, K [1 ]
机构
[1] KYUSHU UNIV,FAC MED,DIV CARDIOVASC SURG,FUKUOKA 812,JAPAN
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
From February 1975 through October 1981, 256 Hancock porcine bioprostheses (Johnson & Johnson Cardiovascular, King of Prussia, Pa.) (60 aortic, 169 mitral, and 27 pulmonary/tricuspid position) were implanted in 220 patients (104 male and 116 female, aged 9 to 67 years; mean 43.3) at Kyushu University Hospital in Japan. The procedures include 41 aortic valve replacements, 121 mitral valve replacements, 4 pulmonary valve replacements, 6 tricuspid valve replacements, and 48 combined valve replacements (31 aortic plus mitral, 13 mitral plus tricuspid, and 4 aortic plus mitral plus tricuspid). Hospital mortality was 6.4 %. Follow-up was 98 % during 8 to 14 (mean 10.5) years. Cumulative follow-up was 1836 patient-years and 2078 valve-years. At 10 years the overall actuarial survival rate, including hospital mortality, was 70 % +/- 3 %, and freedom from valve-related mortality with sudden death was 87 % +/- 3 %. More than half of the current survivors required no anticoagulant therapy. Freedom from thromboembolism or anticoagulant-related hemorrhage (or both) and prosthetic valve endocarditis was common. Freedom from structural valve failure and reoperation declined more than 9 years after replacement of left-sided heart valves but not after replacement of right-sided heart valves. Sixty-seven patients underwent 68 repeat operations, and there were four deaths (5.9 %). The rate of freedom from overall valve-related complications at 10 years was 62 % +/- 8 % for aortic valve replacement, 53 % +/- 5 % for mitral valve replacement, 80 % +/- 13 % for pulmonary/tricuspid valve replacement, and 42 % +/- 9 % for combined valve replacement. There was a significant difference between pulmonary/tricuspid valve replacement and combined valve replacement (p < 0.05). The Hancock bioprosthesis is suitable for the replacement of valves in the right side of the heart but not for combined valve replacement.
引用
收藏
页码:5 / 13
页数:9
相关论文
共 50 条
  • [21] A LONGITUDINAL CLINICAL-STUDY OF CHILDREN WITH GRAND MAL - FOLLOW-UP FOR MORE THAN 10 YEARS
    KANEMATSU, S
    MAEDA, R
    FUKUHARA, M
    TSUCHIYA, S
    MARUYAMA, H
    FUKUYAMA, Y
    BRAIN & DEVELOPMENT, 1985, 7 (02): : 180 - 180
  • [22] RENAL BIOPSY IN 31 KIDNEY-TRANSPLANT RECIPIENTS WITH MORE THAN 10 YEARS OF FOLLOW-UP
    IANHEZ, LE
    SALDANHA, LB
    ARAP, S
    SABBAGA, E
    TRANSPLANTATION PROCEEDINGS, 1989, 21 (01) : 2187 - 2189
  • [23] Long-term outcome of ureterosigmoidostomy: An analysis of patients with more than 10 years of follow-up
    Tollefson, Matthew K.
    Chrouser, Kristin L.
    Elliott, Daniel S.
    Zincke, Horst
    Frank, Igor
    JOURNAL OF UROLOGY, 2008, 179 (04): : 250 - 250
  • [24] Long-term results of synovectomy for rheumatoid elbow with more than 10 years follow-up
    Ishii, K.
    Inaba, Y.
    Saito, T.
    Aratake, M.
    Nakashima, K.
    Kobayashi, N.
    Kawakami, Y.
    Matsuo, K.
    ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 : 354 - 354
  • [25] Treatment of patellofemoral chondropathy with the Bandi tibial tubercle osteotomy More than 10 years follow-up
    Valenzuela, Luis
    Nemtala, Fernando
    Orrego, Mario
    Mardones, Rodrigo
    Matas, Jose
    Sudy, Hernan
    Durruty, Juan
    KNEE, 2011, 18 (02): : 94 - 97
  • [26] Cementless total hip arthroplasty for haemophilic arthropathy: follow-up result of more than 10 years
    Lee, S. H.
    Rhyu, K. H.
    Cho, Y. J.
    Yoo, M. C.
    Chun, Y. S.
    HAEMOPHILIA, 2015, 21 (01) : E54 - E58
  • [27] Emerging comorbidities in Graves' disease patients treated with radioiodine with more than 10 years of follow-up
    Ramalho de Azevedo, Fernanda Vieira
    da Silva Blotta, Francisco Gomes
    Goirgetta, Juliana Malheiros
    Noe, Rosangela
    Vaisman, Mario
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2013, 57 (01) : 51 - 56
  • [28] More Than 10 Years Clinical Follow-up After Endovascular Therapy Patients With Intermittent Claudication
    Soga, Yoshimitsu
    Yokoi, Hiroyoshi
    Ando, Kenji
    Shirai, Shinichi
    Sakai, Koyu
    Iwabuchi, Masashi
    Nobuyoshi, Masakiyo
    CIRCULATION, 2009, 120 (18) : S950 - S950
  • [29] LONG-TERM PERFORMANCE OF THE HANCOCK PORCINE BIOPROSTHESIS IN THE TRICUSPID POSITION - A REVIEW OF 45 PATIENTS WITH 14-YEAR FOLLOW-UP
    GUERRA, F
    BORTOLOTTI, U
    THIENE, G
    MILANO, A
    MAZZUCCO, A
    TALENTI, E
    STELLIN, G
    GALLUCCI, V
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 99 (05): : 838 - 845
  • [30] 5-YEAR TO 8-YEAR FOLLOW-UP OF PATIENTS WITH THE HANCOCK CARDIAC BIOPROSTHESIS
    GALLO, I
    RUIZ, B
    DURAN, CMG
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1983, 86 (06): : 897 - 902