OBSERVATION OF THE AG/SI(111) SYSTEM USING A HIGH-RESOLUTION ULTRA-HIGH-VACUUM SCANNING ELECTRON-MICROSCOPE

被引:38
|
作者
ENDO, A
INO, S
机构
[1] Department of Physics, Faculty of Science, University of Tokyo, Bunkyo-ku, Tokyo, 113, 7-3-1, Hongo
关键词
D O I
10.1016/0039-6028(93)90311-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Secondary electron (SE) imaging with a new ultra-high vacuum scanning electron microscope (UHV-SEM) has been employed to study the Ag/Si(111) system. Domains of the square-root 3 x square-root 3-Ag or 6 x 1(3 x 1)-Ag structure partially covering a Si(111) surface are clearly contrasted against the 7 x 7 region. No sample bias is applied. Two-dimensional (2D) domain morphology differs completely between square-root 3 x square-root 3-Ag and 6 x 1(3 x 1)-Ag. The square-root 3 x square-root 3-Ag nucleates at any of (1) the steps, (2) the steps plus phase boundaries, and (3) the steps plus phase boundaries plus mid-domains, of the Si(111)-7 x 7 substrate, depending on both the step spacing and the substrate temperature. An SE image for Ag deposition at approximately room-temperature shows regular arrangements having the same periodicity as the 7 x 7 unit meshes. This implies that 2D Ag clusters, approximately 2.3 nm in size and composed probably of 36 Ag atoms, resulting from the preferential Ag deposition onto faulted halves of the 7 x 7 unit meshes are observed. In our previous papers, the presence of areas with three sorts of brightness for samples with the 7 x 7 and the square-root 3 x square-root 3-Ag structure were reported. This is shown to be caused by the remaining 1 x 1 domains among the 7 x 7 domains, resulting from quenching during the substrate cleaning. Difference between 1 x 1 and 7 x 7 domains and contrast due to steps are observed even without Ag deposition.
引用
收藏
页码:165 / 182
页数:18
相关论文
共 50 条
  • [21] HIGH-RESOLUTION THERMIONIC CATHODE SCANNING TRANSMISSION ELECTRON-MICROSCOPE
    BROERS, AN
    APPLIED PHYSICS LETTERS, 1973, 22 (11) : 610 - 612
  • [22] BACTERIAL SURFACES AS REVEALED BY HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPE
    AMAKO, K
    UMEDA, A
    JOURNAL OF GENERAL MICROBIOLOGY, 1977, 98 (JAN): : 297 - 299
  • [23] HIGH-RESOLUTION AND SPECTROSCOPIC CATHODOLUMINESCENT IMAGES IN SCANNING ELECTRON-MICROSCOPE
    ISHIKAWA, A
    MIZUNO, F
    UCHIKAWA, Y
    MARUSE, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1973, 12 (02) : 286 - 292
  • [24] HIGH-RESOLUTION ELECTRON-MICROSCOPE OBSERVATION OF SMALL GOLD CRYSTALS
    GAO, P
    GLEITER, H
    ACTA METALLURGICA, 1987, 35 (07): : 1571 - 1575
  • [25] HIGH-RESOLUTION ELECTRON-MICROSCOPE OBSERVATION OF CARBON-FIBERS
    ENDO, M
    JOURNAL OF ELECTRON MICROSCOPY, 1984, 33 (01): : 80 - 80
  • [26] HIGH-RESOLUTION Z-CONTRAST OBSERVATION OF GAAS/SI HETEROINTERFACES THROUGH SCANNING-TRANSMISSION ELECTRON-MICROSCOPE
    TAKASUKA, E
    ASAI, K
    FUJITA, K
    CHISHOLM, MF
    PENNYCOOK, SJ
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1992, 31 (12B): : L1788 - L1790
  • [27] LOW-TEMPERATURE ULTRA-HIGH-VACUUM SCANNING TUNNELING MICROSCOPE
    GAISCH, R
    GIMZEWSKI, JK
    REIHL, B
    SCHLITTLER, RR
    TSCHUDY, M
    SCHNEIDER, WD
    ULTRAMICROSCOPY, 1992, 42 : 1621 - 1626
  • [28] HIGH-RESOLUTION SCANNING ELECTRON MICROSCOPE
    CREWE, AV
    SCIENTIFIC AMERICAN, 1971, 224 (04) : 26 - &
  • [29] OBSERVATION OF ULTRA-FINE PALLADIUM PARTICLES ON A FLAT GLASSY-CARBON ELECTRODE WITH A HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPE
    TAKASU, Y
    YAHIKOZAWA, K
    TATEISHI, N
    UENO, M
    MATSUDA, Y
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1990, (03) : 235 - 236
  • [30] APPLICATION OF A HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPE TO BIOLOGICAL-RESEARCH
    TANAKA, K
    JOURNAL OF ELECTRON MICROSCOPY, 1988, 37 (02): : 100 - 101