Shear wave elastography and contrast-enhanced ultrasonography in the diagnosis of thyroid malignant nodules

被引:38
|
作者
Chen, Mei [1 ]
Zhang, Ke-Qin [2 ]
Xu, You-Feng [1 ]
Zhang, Sheng-Min [1 ]
Cao, Yong [1 ]
Sun, Wei-Qun [1 ]
机构
[1] Zhejiang Univ, Ningbo Hosp 1, Dept Ultrasonog, Sch Med, Ningbo 315000, Zhejiang, Peoples R China
[2] Tongji Univ, Dept Endocrinol, Affiliated Hosp, 389 Xincun Rd, Shanghai 200065, Peoples R China
关键词
ultrasonography; contrast media; thyroid nodule; malignant; benign;
D O I
10.3892/mco.2016.1053
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to evaluate the value of shear wave elastography (SWE) and contrast-enhanced ultrasonography (CEUS) in the diagnosis of thyroid malignant nodules. A total of 253 patients with 319 thyroid nodules were subjected to two-dimensional ultrasound (2DUS) and CEUS examinations prior to thyroidectomy between March, 2014 and December, 2015. Young's modulus value for each nodule on 2DUS and CEUS images were recorded. The sensitivity, specificity and accuracy of 2DUS, SWE and CEUS in the diagnosis of thyroid malignant nodules were assessed. The results demonstrated that, of the 319 nodules that were pathologically confirmed, 136 were malignant and 183 were benign. The area under the receiver operating characteristic curve as a result of SWE diagnosis was 0.77. When the threshold of the Young's modulus value was >= 27.65 kPa in the diagnosis of malignant thyroid nodules, SWE exhibited a sensitivity of 84.55% (115/136), a specificity of 84.15% (154/183) and an accuracy of 84.32% (269/319). US contrast imaging of malignant thyroid nodules revealed a major tendency for early hypoenhancement and hypoenhancement. CEUS exhibited a sensitivity of 87.5% (119/136), a specificity of 86.33% (158/183) and an accuracy of 86.83% (277/319) in the diagnosis of malignant thyroid nodules. Compared with 2DUS, SWE, CEUS and their combined use exhibited statistically significant differences in the diagnosis of thyroid malignant nodules in terms of sensitivity, specificity and accuracy (chi(2)=9.220,15.310 and 40.296, respectively; P=0.000); SWE or CEUS did not differ significantly in the diagnosis of thyroid malignant nodules in terms of sensitivity, specificity or accuracy (chi(2)=0.737; P=0.542); Compared with the use of SWE or CEUS alone, their combination exhibited statistically significant differences in the diagnosis of malignant thyroid nodules in terms of sensitivity, specificity and accuracy (chi(2)=12.264 and 6.939, respectively; P=0.000,0.005). In conclusion, the high accuracy of the combined use of SWE and CEUS in the diagnosis of malignant thyroid nodules is of great clinical value.
引用
收藏
页码:724 / 730
页数:7
相关论文
共 50 条
  • [1] Significance of contrast-enhanced ultrasonography in differential diagnosis of thyroid nodules
    Tian, Qing
    Zhu, Haohui
    Li, Hui
    [J]. MEDICINE, 2018, 97 (40)
  • [2] Role of Shear Wave Elastography in Diagnosis of Benign and Malignant Thyroid Nodules
    Bakari, Khamis Hassan
    Simai, Khamis Abdulrahman
    Mghanga, Fabian Pius
    Mayala, Henry Anselmo
    Xie Mingxing
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (09) : TC5 - TC8
  • [3] Application of ultrasonic shear wave elastography and contrast-enhanced ultrasound in the differential diagnosis of patients with benign and malignant thyroid lesions
    Xu, Jing
    Wang, Ping
    Yue, Wensheng
    Luo, Yuqun
    Li, Zukun
    [J]. GLAND SURGERY, 2020, 9 (06) : 2136 - 2143
  • [4] Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules
    Sui, Xin
    Liu, Huai-Jun
    Jia, Hong-Li
    Fang, Qin-Mao
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (02) : 783 - 791
  • [5] Use of Contrast-Enhanced Ultrasonography and Shear-Wave Elastography in the Diagnosis of Granulomatous Colitis in a French Bulldog
    Cordella, Alessia
    Stock, Emmelie
    Van de Maele, Isabel
    Willems, Annelies
    Saunders, Jimmy
    [J]. VETERINARY SCIENCES, 2021, 8 (07)
  • [6] Differentiation of Thyroid Nodules Difficult to Diagnose With Contrast-Enhanced Ultrasonography and Real-Time Elastography
    Xi, Xuehua
    Gao, Luying
    Wu, Qiong
    Fang, Shibao
    Xu, Jingzhu
    Liu, Ruyu
    Yang, Xiao
    Zhu, Shenling
    Zhao, Ruina
    Lai, Xingjian
    Zhang, Xiaoyan
    Zhang, Bo
    Jiang, Yuxin
    [J]. FRONTIERS IN ONCOLOGY, 2020, 10
  • [7] VALUE OF CONVENTIONAL ULTRASONOGRAPHY WITH CONTRAST-ENHANCED ULTRASONOGRAPHY IN THE DIFFERENTIAL DIAGNOSIS OF PARTIAL CYSTIC THYROID NODULES
    Song, Qing
    Tian, Xiaoqi
    Jiao, Ziyu
    Yan, Lin
    Lan, Yu
    Zhu, Yaqiong
    Luo, Yukun
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09): : 2494 - 2501
  • [8] Influence of lesion size on shear wave elastography in the diagnosis of benign and malignant thyroid nodules
    Li, Huizhan
    Kang, Chunsong
    Xue, Jiping
    Jing, Liwei
    Miao, Junwang
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Influence of lesion size on shear wave elastography in the diagnosis of benign and malignant thyroid nodules
    Huizhan Li
    Chunsong Kang
    Jiping Xue
    Liwei Jing
    Junwang Miao
    [J]. Scientific Reports, 11
  • [10] Quantitative analysis of suspicious thyroid nodules by contrast-enhanced ultrasonography
    Hu, Yizhou
    Li, Ping
    Jiang, Shufei
    Li, Fenghua
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (07): : 11786 - 11793