Application of ultrasonic shear wave elastography and contrast-enhanced ultrasound in the differential diagnosis of patients with benign and malignant thyroid lesions

被引:18
|
作者
Xu, Jing [1 ]
Wang, Ping [2 ]
Yue, Wensheng [2 ]
Luo, Yuqun [2 ]
Li, Zukun [2 ]
机构
[1] Sichuan Prov Peoples Hosp, Dept Radiol, East Branch Hosp, Chengdu, Peoples R China
[2] North Sichuan Med Coll, Dept Ultrasound, Affiliated Hosp, 63 Wenhua Rd, Shunqing Dist 637000, Nanchong, Peoples R China
关键词
Ultrasonic shear wave elastography (ultrasonic SWE); contrast-enhanced ultrasound (CEUS); thyroid lesion; differential diagnosis; NODULES;
D O I
10.21037/gs-20-819
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Thyroid nodules are a common thyroid disorder. The aim of the present study was to observe the application value of ultrasonic shear wave elastography (SWE) and contrast-enhanced ultrasound (CEUS) in the differential diagnosis of patients with benign and malignant thyroid lesions. Methods: Eighty-two patients with thyroid nodules (96 thyroid nodules) at our hospital were enrolled. All patients underwent ultrasonic SWE and CEUS examination. With surgical pathology as the gold standard, the Young's modulus, CEUS imaging features, and quantitative parameters were compared between the benign and malignant groups. The diagnostic efficiency of SWE, CEUS, and their combination was analyzed by receiver-operating characteristic curve (ROC). Results: The average of the Young's modulus in the malignant group was significantly higher than that of the benign group (P<0.05). There were significant differences in the CEUS images of nodules between the benign and malignant groups in terms of boundary conditions, morphology, perfusion intensity, homogeneous enhancement, and perfusion defects (P<0.05), while there were no significant difference in initial increase time, peak intensity, time to peak, and area under the curve (P>0.05). The curve sharpness in the benign group was significantly lower than that of the malignant group (P<0.05). ROC analysis found that the diagnostic sensitivity and specificity of SWE, CEUS, and their combination were 90.1% and 81.6%, 67.8% and 75.4%, and 97.3% and 71.5%, respectively. Conclusions: Compared with CEUS, the sensitivity and specificity of SWE were relatively higher in the differential diagnosis of benign and malignant thyroid lesions, and a combination of both can improve the diagnostic sensitivity of SWE alone to a certain extent.
引用
收藏
页码:2136 / 2143
页数:8
相关论文
共 50 条
  • [1] Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
    He, Huiling
    Wu, Xiaojin
    Jiang, Meijuan
    Xu, Zhikang
    Zhang, Xuanxuan
    Pan, Jianlian
    Fu, Xinyu
    Luo, Yunkai
    Chen, Jian
    [J]. GLAND SURGERY, 2023, : 54 - 66
  • [2] Application of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Benign and Malignant Subpleural Pulmonary Lesions
    Shen, MengJun
    Bi, Ke
    Cong, Yang
    Chen, HongWei
    Zhang, Yi
    Zhu, HuiMing
    Wang, Yin
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1147 - 1157
  • [3] Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules
    Sui, Xin
    Liu, Huai-Jun
    Jia, Hong-Li
    Fang, Qin-Mao
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (02) : 783 - 791
  • [4] Shear wave elastography and contrast-enhanced ultrasonography in the diagnosis of thyroid malignant nodules
    Chen, Mei
    Zhang, Ke-Qin
    Xu, You-Feng
    Zhang, Sheng-Min
    Cao, Yong
    Sun, Wei-Qun
    [J]. MOLECULAR AND CLINICAL ONCOLOGY, 2016, 5 (06) : 724 - 730
  • [5] Clinical value and application of contrast-enhanced ultrasound in the differential diagnosis of malignant and benign breast lesions
    Zhang, Yan
    Zhang, Bmeiwu
    Fan, Xiaoxiang
    Mao, Dafeng
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (03) : 2063 - 2069
  • [6] The value of contrast-enhanced ultrasound versus shear wave elastography in differentiating benign and malignant superficial lymph node lesions
    Cai, Huahai
    Liu, Shuyu
    [J]. AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (10): : 11625 - 11631
  • [7] Value of differential diagnosis of contrast-enhanced ultrasound in benign and malignant thyroid nodules with microcalcification
    Gao, Zhixiang
    Lu, Qin
    Yan, Jiping
    [J]. ONCOLOGY LETTERS, 2019, 17 (05) : 4545 - 4549
  • [8] The Role of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Malignant and Benign Subpleural Lung Lesions
    Boccatonda, Andrea
    Guagnano, Maria Teresa
    D'Ardes, Damiano
    Cipollone, Francesco
    Vetrugno, Luigi
    Schiavone, Cosima
    Piscaglia, Fabio
    Serra, Carla
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [9] Value of ultrasound elastography combined with contrast-enhanced ultrasound and micro-flow imaging in differential diagnosis of benign and malignant breast lesions
    Ding, Zuopeng
    Liu, Weiyong
    He, Nianan
    Ma, Xiaopeng
    Fu, Lili
    Ye, Lei
    [J]. AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (12): : 13941 - 13949
  • [10] Diagnosis of Benign and Malignant BI-RADS 4 Breast Masses by Contrast-enhanced Ultrasound Combined with Shear Wave Elastography
    Weng, Lifeng
    Yu, Mengxia
    [J]. CURRENT MEDICAL IMAGING, 2023,