FAST-NEUTRON DOSIMETRY WITH CR-39 USING ELECTROCHEMICAL ETCHING

被引:0
|
作者
FERNANDEZ, F
DOMINGO, C
BAIXERAS, C
LUGUERA, E
ZAMANI, M
DEBEAUVAIS, M
机构
[1] UNIV THESSALONIKI,DEPT NUCL PHYS,GR-54006 SALONIKA,GREECE
[2] CTR RECH NUCL,F-67037 STRASBOURG,FRANCE
来源
关键词
NEUTRON DOSIMETRY; NEUTRON RESPONSE; MONTE-CARLO METHOD; CR-39; ELECTROCHEMICAL ETCHING; DETECTION EFFICIENCY;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A Monte Carlo method is used in order to calculate the response (tracks.cm-2.mu-Sv-1) of a fast neutron dosemeter, composed of a polyethylene radiator and CR-39 plastic track detector, to monoenergetic neutron beams at normal incidence and taking into account the electrochemical etching conditions. The method is applied to neutrons having energies in the range 0.08-10 MeV. The total number of protons emerging from the radiator is calculated, as well as their energetic and angular distribution. Detection efficiency as a function of proton energy and angle is taken into account. The theoretical calculation is compared with experimental results obtained for Am-Li and Pu-Be sources for protonic equilibrium radiator thicknesses
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [31] FAST-NEUTRON SPECTROMETRY BASED ON PROTON DETECTION IN CR-39 DETECTOR
    DAJKO, G
    SOMOGYI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 607 - 610
  • [32] FAST-NEUTRON SPECTROMETRY USING THE TRIPLE-ALPHA REACTION IN THE CR-39 DETECTOR
    ALNAJJAR, SAR
    ABDELNABY, A
    DURRANI, SA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 611 - 615
  • [33] DEVELOPMENT OF A PERSONNEL FAST-NEUTRON DOSIMETER BASED ON CR-39 DETECTORS
    MUTIULLAH
    DURRANI, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 27 (03): : 465 - 469
  • [34] FLAT ANGULAR RESPONSE OF A FAST-NEUTRON DOSIMETER USING CYLINDRICAL SHAPED CR-39
    ALNAJJAR, SAR
    PIESCH, E
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 161 - 164
  • [35] CHEMICAL AND ELECTROCHEMICAL REGISTRATION OF PROTONS IN CR-39 - IMPLICATIONS FOR NEUTRON DOSIMETRY
    MATIULLAH
    DURRANI, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 29 (03): : 508 - 514
  • [36] CR-39 acceptance test and optimisation for fast neutron dosimetry applications
    Fantuzzi, E
    Morelli, B
    Falangi, G
    Patrizii, L
    Togo, V
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 573 - 578
  • [37] CR-39 acceptance test and optimisation for fast neutron dosimetry applications
    Fantuzzi, E
    Morelli, B
    Falangi, G
    Patrizii, L
    Togo, V
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A573 - A578
  • [38] LOW LEVEL FAST NEUTRON DOSIMETRY USING CR-39 PLASTICS SHEETS.
    Tawara, H.
    Takahashi, H.
    Watanabe, I.
    Doke, T.
    Kang, Yung-ho
    Miyajima, M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1987, B23 (03) : 369 - 373
  • [39] Performance of CR-39® with addition of DOP (dioctylphthalate) for fast neutron dosimetry
    Fantuzzi, E
    Marlotti, F
    Falangi, G
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 475 - 478
  • [40] Determination of CR-39 detection efficiency for fast neutron registration and the absolute neutron dosimetry
    El-Sersy, AR
    Khaled, NE
    Eman, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 215 (3-4): : 443 - 448