FAST-NEUTRON DOSIMETRY WITH CR-39 USING ELECTROCHEMICAL ETCHING

被引:0
|
作者
FERNANDEZ, F
DOMINGO, C
BAIXERAS, C
LUGUERA, E
ZAMANI, M
DEBEAUVAIS, M
机构
[1] UNIV THESSALONIKI,DEPT NUCL PHYS,GR-54006 SALONIKA,GREECE
[2] CTR RECH NUCL,F-67037 STRASBOURG,FRANCE
来源
关键词
NEUTRON DOSIMETRY; NEUTRON RESPONSE; MONTE-CARLO METHOD; CR-39; ELECTROCHEMICAL ETCHING; DETECTION EFFICIENCY;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A Monte Carlo method is used in order to calculate the response (tracks.cm-2.mu-Sv-1) of a fast neutron dosemeter, composed of a polyethylene radiator and CR-39 plastic track detector, to monoenergetic neutron beams at normal incidence and taking into account the electrochemical etching conditions. The method is applied to neutrons having energies in the range 0.08-10 MeV. The total number of protons emerging from the radiator is calculated, as well as their energetic and angular distribution. Detection efficiency as a function of proton energy and angle is taken into account. The theoretical calculation is compared with experimental results obtained for Am-Li and Pu-Be sources for protonic equilibrium radiator thicknesses
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [1] Fast neutron dosimetry with CR-39 using electrochemical etching
    Fernandez, F.
    Domingo, C.
    Baixeras, C.
    Luguera, E.
    Zamani, M.
    Debeauvais, M.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 467 - 470
  • [2] ON THE OPTIMIZATION OF THE ETCHING OF CR-39 AS A FAST-NEUTRON DOSIMETER
    TUREK, K
    SPURNY, F
    ALBERTS, WG
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (02): : 299 - 300
  • [3] FAST-NEUTRON DOSIMETRY USING A CR-39 PLASTIC TRACK DETECTOR
    KHAN, HA
    KHAN, NA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (2-3): : 491 - 497
  • [4] DOSIMETRY IN FAST-NEUTRON THERAPY BY AUTOMATIC READOUT OF CR-39
    BLUE, TE
    WEHRING, BW
    BRIGGS, SJ
    WEPPRECHT, CS
    DURHAM, JS
    BLUE, JW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 14 (4-6): : 589 - 595
  • [5] PROPERTIES OF ELECTROCHEMICALLY ETCHED CR-39 PLASTIC FOR FAST-NEUTRON DOSIMETRY
    ALNAJJAR, SAR
    NINOMIYA, K
    PIESCH, E
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 165 - 169
  • [6] LOW-LEVEL FAST-NEUTRON DOSIMETRY USING CR-39 PLASTIC SHEETS
    TAWARA, H
    TAKAHASHI, H
    WATANABE, I
    DOKE, T
    KANG, YH
    MIYAJIMA, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 23 (03): : 369 - 373
  • [7] PERSONNEL NEUTRON DOSIMETRY USING AN IMPROVED TECHNIQUE FOR ELECTROCHEMICAL ETCHING OF CR-39 PLASTIC
    HANKINS, DE
    HOMANN, SG
    DAVIS, JM
    HEALTH PHYSICS, 1985, 49 (01): : 141 - 141
  • [8] FAST-NEUTRON DOSIMETRY WITH SOLID-STATE TRACK DETECTOR CR-39
    TSURUTA, T
    JUTO, N
    FUKUMOTO, Y
    HEALTH PHYSICS, 1983, 44 (03): : 289 - 289
  • [9] PARTIAL OPTIMIZATION OF ELECTROCHEMICAL-ETCHING PARAMETERS FOR HIGHLY SENSITIVE CR-39 FAST-NEUTRON DOSIMETERS
    GAMMAGE, RB
    CHOWDHURY, A
    HEALTH PHYSICS, 1982, 43 (02): : 225 - 229
  • [10] NEW ETCHING CONDITIONS FOR CR-39 FOR NEUTRON DOSIMETRY
    AZIMIGARAKANI, D
    BOSCHUNG, M
    WERNLI, C
    RADIATION PROTECTION DOSIMETRY, 1991, 35 (02) : 93 - 98