DIFFUSION WEIGHTING BY THE TRACE OF THE DIFFUSION TENSOR WITHIN A SINGLE SCAN

被引:228
|
作者
MORI, S
VANZIJL, PCM
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT RADIOL,BALTIMORE,MD 21205
[2] JOHNS HOPKINS UNIV,SCH MED,DEPT BIOPHYS,BALTIMORE,MD 21205
关键词
MAGNETIC RESONANCE IMAGING; DIFFUSION TENSER; TRACE; STROKE;
D O I
10.1002/mrm.1910330107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The anisotropy of the water diffusion tenser inside brain causes contrast in diffusion images, which depends on the relative orientation of the diffusion gradients and the subject. Because the trace of a tenser is invariant upon rotation, measurement of this trace can reduce the orientation effect. A family of imaging pulse sequences is presented in which the signal intensity is weighted by the trace of the diffusion tenser in a single scan. The methods are demonstrated for chicken gizzard in several orientations with respect to the gradient frame of reference, and for ischemic injury in cat brain after middle cerebral artery occlusion. The sensitivity of the techniques to the presence of background gradients is measured and discussed in detail. As a result, pulse sequences are suggested that provide reliable diffusion constants in both homogeneous and inhomogeneous magnetic fields. The efficiency of the techniques for clinical application is also evaluated.
引用
收藏
页码:41 / 52
页数:12
相关论文
共 50 条
  • [21] Introduction to diffusion tensor imaging mathematics: Part II. Anisotropy, diffusion-weighting factors, and gradient encoding schemes
    Kingsley, PB
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2006, 28A (02) : 123 - 154
  • [22] Line scan diffusion tensor MRI of the cervical spinal cord in preterm infants
    Murphy, BP
    Zientara, GP
    Huppi, PS
    Maier, SE
    Barnes, PD
    Jolesz, FA
    Volpe, JJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 949 - 953
  • [23] Diffusion and Diffusion Tensor Imaging in Brain Cancer
    Gerstner, Elizabeth R.
    Sorensen, A. Gregory
    SEMINARS IN RADIATION ONCOLOGY, 2011, 21 (02) : 141 - 146
  • [24] Incomplete initial nutation diffusion imaging: An ultrafast, single-scan approach for diffusion mapping
    Ianus, Andrada
    Shemesh, Noam
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2198 - 2204
  • [25] OPTIMIZED ISOTROPIC DIFFUSION WEIGHTING
    WONG, EC
    COX, RW
    SONG, AW
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) : 139 - 143
  • [26] Diffusion in a single crystal within a stressed environment
    Cowern, N. E. B.
    PHYSICAL REVIEW LETTERS, 2007, 99 (15)
  • [27] On diffusion tensor estimation
    Niethammer, Marc
    Estepar, Raul San Jose
    Bouix, Sylvain
    Shenton, Martha
    Westin, Carl-Fredrik
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3110 - +
  • [28] DIFFUSION TENSOR OF A PLASMA
    MIDHA, JM
    CURRENT SCIENCE, 1984, 53 (17): : 913 - 913
  • [29] Error propagation framework for diffusion tensor imaging via diffusion tensor representations
    Koay, Cheng Guan
    Chang, Lin-Ching
    Pierpaoli, Carlo
    Basser, Peter J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (08) : 1017 - 1034
  • [30] An Exploration of Diffusion Tensor Eigenvector Variability Within Human Calf Muscles
    Rockel, Conrad
    Noseworthy, Michael D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 190 - 202