Aim: We compared the visual performance of toric intraocular lenses (IOLs) and non-toric IOLs made of the same material. Patients and materials: The subjects included patients implanted with either Acrysof IQ (R) toric IOLs (SN6AT3-9) or Acrysof IQ (R) IOLs (SN60WF) bilaterally. The toric group included 103 patients who were implanted with Acrysof IQ toric IOLs bilaterally. The non-toric group was a corneal astigmatism-matched control group and included 103 patients who were implanted with Acrysof IQ IOLs bilaterally. Results: The uncorrected distance visual acuity was significantly better in the toric group, whereas the uncorrected 50 cm visual acuity was better in the non-toric group. There was no significant difference in contrast sensitivity (with and without glare) between both the groups. The rate of spectacle dependency for distance vision was significantly lower in the toric group. There were no significant differences between the two groups in all items of the postoperative quality-of-vision questionnaire (25-item Visual Function Questionnaire). Conclusion: The toric IOLs used in this study reduced spectacle dependency more than the non-toric IOLs and did not compromise the subjective visual function, but the uncorrected 50 cm vision was worse in toric IOL implanted eyes.
引用
收藏
页码:2237 / 2243
页数:7
相关论文
共 50 条
  • [31] Toric intraocular lenses [Torische Intraokularlinsen]
    Auffarth G.U.
    [J]. Der Ophthalmologe, 2007, 104 (12): : 1022 - 1023
  • [32] Refractive Outcomes for Toric Intraocular Lenses
    Simpson, Michael J.
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 945 - 946
  • [33] Comparison of Astigmatism Prediction Error Taken with Galilei, Barrett Formula for Non-toric Intraocular Lens Implantation
    Ho, Yi-Ju
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [34] Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
    Zhao, Jiao
    Zhao, Jing
    Yang, Wen
    Miao, Huamao
    Niu, Lingling
    Shang, Jianmin
    Wang, Xiaoying
    Zhou, Xingtao
    [J]. FRONTIERS IN MEDICINE, 2021, 8
  • [35] The effect of toric and non-toric IOLs on refractive cylinder after cataract surgery
    Zheng, Lei
    Merriam, John C.
    Zheng, Lei
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [36] Probing non-toric geometry with rotating membranes
    Lee, Jung Hun
    Kim, Sunchang
    Kim, Jongwook
    Kim, Nakwoo
    [J]. NUCLEAR PHYSICS B, 2010, 838 (1-2) : 238 - 252
  • [37] Intraoperative aberrometry versus standard preoperative biometry in non-toric and toric IOL calculations
    Bauer, N. J. C.
    Webers, V. S. C.
    Nuijts, R. M. M. A.
    [J]. ACTA OPHTHALMOLOGICA, 2017, 95 : 34 - 34
  • [38] Optical quality comparison between spherical and aspheric toric intraocular lenses
    Perez-Vives, Carl
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Montes-Mico, Robert
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (05) : 699 - 706
  • [39] Berechnung torischer IntraokularlinsenDetermination of toric intraocular lenses
    A. Langenbucher
    Anja Viestenz
    N. Szentmáry
    W. Behrens-Baumann
    A. Viestenz
    [J]. Der Ophthalmologe, 2008, 105 : 685 - 692
  • [40] Calculating the power of toric phakic intraocular lenses
    Langenbucher, Achim
    Szentmary, Nora
    Seitz, Berthold
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2007, 27 (04) : 373 - 380