DEVELOPMENT OF A 50-60 HZ THERMALLY SWITCHED SUPERCONDUCTING RECTIFIER

被引:5
|
作者
Shevchenko, O. A. [1 ]
ten Kate, H. H. J. [1 ]
Krooshoop, H. J. G. [1 ]
Markovsky, N. V. [2 ]
Mulder, G. B. J. [3 ]
机构
[1] Univ Twente, Ctr Appl Superconduct, POB 217, NL-7500 AE Enschede, Netherlands
[2] Ukraine Acad Sci, Inst Electrodynam, Pobeda Prospect 56, UA-57252680 Kiev, Ukraine
[3] Phillips Med Syst Nederland, Amsterdam, Netherlands
关键词
D O I
10.1109/77.233774
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A full-wave thermally switched superconducting rectifier, able to operate directly from the mains at the 50-60 Hz frequency, has been developed in our institute. Typical design output values of this device are: current 300 A, voltage up to 1 V, average power up to 100 VA and an efficiency better than 95 %. The rectification is achieved by means of fast-response switches and an iron core transformer. A simple and reliable algorithm for the rectifier operation, based on the measured current change across the switches, is developed and tested while powering a small magnet. The new features of the rectifier presented allows for a simplification of the construction and a significant reduction of cost, mass and volume.
引用
收藏
页码:590 / 593
页数:4
相关论文
共 50 条
  • [41] MEASUREMENT OF 50 HZ DISSIPATION IN SUPERCONDUCTING NIOBIUM STRIPS
    GRIGSBY, R
    SLAUGHTER, RJ
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1970, 3 (06) : 898 - +
  • [42] 50 HZ ROTATING SUPERCONDUCTING MAGNET FOR SCREENING STUDIES
    SCURLOCK, RG
    STOLL, R
    STOVOLD, R
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (05) : 2198 - 2200
  • [43] AN IMPROVED 60 HZ SUPERCONDUCTING POWER TRANSMISSION CABLE
    MORGAN, GH
    SCHAUER, F
    THOMAS, RA
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) : 157 - 160
  • [44] STUDY OF SERVICEABILITY OF SUPERCONDUCTING WIRES AT 50 - HZ FREQUENCY
    AKSENOVA, EN
    AKSENOV, PV
    KRUGLOV, VS
    ZELENSKY, GK
    NIKULENKOV, EV
    IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (02) : 2116 - 2118
  • [45] NBTI THERMALLY CONTROLLED SWITCHES FOR SUPERCONDUCTING CONVERTERS WITH OPERATION FREQUENCY UP TO 50 HZ .2. THEORY AND ANALYSIS
    MULDER, GBJ
    SHEVCHENKO, OA
    FEDOROVSKY, MA
    TENKATE, HHJ
    CRYOGENICS, 1992, 32 : 451 - 454
  • [46] NBTI FOIL THERMALLY CONTROLLED SWITCHES FOR SUPERCONDUCTING CONVERTERS WITH OPERATION FREQUENCY UP TO 50 HZ .1. EXPERIMENT
    SHEVCHENKO, OA
    MULDER, GBJ
    MARKOVSKY, NV
    TENKATE, HHJ
    CRYOGENICS, 1992, 32 : 447 - 450
  • [47] THEORETICAL EVALUATION OF LONGITUDINAL AC LOSSES IN LARGE-CAPACITY SUPERCONDUCTING CABLES FOR 50/60 HZ USE
    FUNAKI, K
    UEDA, H
    YOSHIYA, F
    IWAKUMA, M
    TAKEO, M
    YAMAFUJI, K
    CRYOGENICS, 1993, 33 (02) : 190 - 198
  • [48] Development and integration of a 50 Hz pellet injection system for the Experimental Advanced Superconducting Tokamak (EAST)
    Yao, Xingjia
    Chen, Yue
    Hu, Jiansheng
    Vinyar, Igor
    Lukin, Alexander
    Yuan, Xiaoling
    Li, Changzheng
    Liu, Haiqing
    FUSION ENGINEERING AND DESIGN, 2017, 114 : 40 - 46
  • [49] A 50-60 GHz Rectifier with-7 dBm Sensitivity for 1 V DC Output Voltage and 8% Efficiency in 65-nm CMOS
    Gao, Hao
    Matters-Kammerer, Marion K.
    Milosevic, Dusan
    van Roermund, Arthur
    Baltus, Peter
    2014 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2014,