LONG-TERM STORAGE OF NICKEL HYDROGEN CELLS

被引:8
|
作者
VAIDYANATHAN, H
机构
[1] COMSAT, Clarksburg, MD, USA, COMSAT, Clarksburg, MD, USA
关键词
ELECTROLYTIC CELLS - Storage;
D O I
10.1016/0378-7753(88)80017-X
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Representative samples of nickel-hydrogen cells for the INTELSAT VI program were used to evaluate the effects of prolonged storage under passive conditions, such as open-circuit discharged at 0 degree C, room temperature, and minus 20 degree C, and under quasidynamic conditions such as top-off charge and trickle charge. Cell capacity declines when cells are stored open-circuit discharged at room temperature, and a second plateau occurs in the discharge curve. Capacity loss was 47% for a cell with hydrogen precharge and 24. 5% for one with no hydrogen precharge. Capacity recovery was observed following top-off charge storage of cells which had exhibited faded capacity as a result of passive storage at room temperature. Cells stored either at minus 20 degree C or on trickle charge maintained their capacity. At 0 degree C storage, the capacity of all three cells under test was greater than 55 A h (which exceeds the required minimum of 44 A h) after 7 months.