THE CHARACTERIZATION OF SYNTHETIC BY-PRODUCTS BY B/E LINKED SCANNING AND HIGH-RESOLUTION THERMOSPRAY MASS-SPECTROMETRY

被引:4
|
作者
DINALLO, RM
DAVIDSON, WC
HANSEN, GE
机构
[1] Department of Analytical Sciences, Boehringer Ingelheim Pharmaceuticals Inc, Research and Development Center, Ridgefield, Connecticut
关键词
D O I
10.1002/bms.1200200506
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Characterization of unknown synthetic by-products from a test synthesis of the experimental inhibitor of HIV-1 reverse transcriptase, BI-RG-587, is presented. Seven impurities were separated and characterized by thermospray liquid chromatography/mass spectrometry using low-resolution, high-resolution, and B/E linked scanning methods. The high-resolution mass measurements which were obtained were accurate to within 10 ppm of structures proposed for synthetic by-products present at the 0.1% level. Linked scans produced daughter ion spectra for each impurity to further aid in the characterization.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 50 条
  • [1] ANALYSIS OF CANDIDATE ANTICANCER DRUGS BY THERMOSPRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND BY HIGH-RESOLUTION MASS-SPECTROMETRY
    VOYKSNER, RD
    WILLIAMS, FP
    HINES, JW
    JOURNAL OF CHROMATOGRAPHY, 1985, 347 (01): : 137 - 146
  • [2] MIXTURE ANALYSIS BY HIGH-RESOLUTION MASS-SPECTROMETRY MASS-SPECTROMETRY
    RUSSELL, DH
    MCBAY, EH
    MUELLER, TR
    INTERNATIONAL LABORATORY, 1980, 10 (03): : 49 - &
  • [3] MIXTURE ANALYSIS BY HIGH-RESOLUTION MASS-SPECTROMETRY MASS-SPECTROMETRY
    RUSSELL, DH
    MCBAY, EH
    MUELLER, TR
    AMERICAN LABORATORY, 1980, 12 (03) : 50 - &
  • [4] HIGH-RESOLUTION LASER MASS-SPECTROMETRY
    NEUSSER, HJ
    BOESL, U
    WEINKAUF, R
    SCHLAG, EW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 60 (SEP): : 147 - 156
  • [5] Characterization of Disinfection By-Products from Chromatographically Isolated NOM through High-Resolution Mass Spectrometry
    Harris, Bradley D.
    Brown, Taylor A.
    McGehee, Jimmie L.
    Houserova, Dominika
    Jackson, Benjamin A.
    Buchel, Brandon C.
    Krajewski, Logan C.
    Whelton, Andrew J.
    Stenson, Alexandra C.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (24) : 14239 - 14248
  • [6] Characterization of Disinfection By-Products in Arkhangelsk Tap Water by Liquid Chromatography/High-Resolution Mass Spectrometry
    Kosyakov, D. S.
    Ul'yanovskii, N. V.
    Popov, M. S.
    Latkin, T. B.
    Lebedev, A. T.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (13) : 1260 - 1268
  • [7] Characterization of Disinfection By-Products in Arkhangelsk Tap Water by Liquid Chromatography/High-Resolution Mass Spectrometry
    D. S. Kosyakov
    N. V. Ul’yanovskii
    M. S. Popov
    T. B. Latkin
    A. T. Lebedev
    Journal of Analytical Chemistry, 2018, 73 : 1260 - 1268
  • [8] High-Resolution Mass Spectrometry and Chemometrics for the Detailed Characterization of Short Endogenous Peptides in Milk By-Products
    Montone, Carmela Maria
    Aita, Sara Elsa
    Cavaliere, Chiara
    Cerrato, Andrea
    Lagana, Aldo
    Piovesana, Susy
    Capriotti, Anna Laura
    MOLECULES, 2021, 26 (21):
  • [9] CHOOSING BETWEEN HIGH-RESOLUTION MASS-SPECTROMETRY AND MASS-SPECTROMETRY MASS-SPECTROMETRY - ENVIRONMENTAL APPLICATIONS
    CHARLES, MJ
    TONDEUR, Y
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (12) : 1856 - 1860
  • [10] IDENTIFICATION OF BY-PRODUCTS IN PHENYLISOCYANATE PRECOLUMN DERIVATIZATION BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    RAKOTOMANGA, S
    BAILLET, A
    PELLERIN, F
    BAYLOCQFERRIER, D
    CHROMATOGRAPHIA, 1991, 32 (3-4) : 125 - 129