Dual-energy CT of liver metastases in patients with uveal melanoma

被引:5
|
作者
Altenbernd, Jens [1 ]
Wetter, Axel [1 ]
Forsting, Michael [1 ]
Umutlu, Lale [1 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Hufelandstr 55, D-45122 Essen, Germany
来源
关键词
Dual energy CT; Liver; Uveal melanoma; Angiography; Staging;
D O I
10.1016/j.ejro.2016.10.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the value of different kVp images of dual-energy CT (DECT) for the detection of liver metastases. Methods: 20 Patients with uveal melanoma were investigated with DECT of the liver. In each patient contrast-enhanced DECT imaging with arterial delay was performed. Number and size of metastases were documented on arterial phase 80-kVp images, virtual 120-kVp images and following angiographic images (DSA) as part of hepatic chemoperfusion. Attenuation of metastases and several anatomic regions, subjective (image noise, image quality) and objective (SNR, CNR) parameters were documented. Results: The mean number of liver metastases detected was significant higher on 80-kVp images than on virtual 120-kVp/DSA images (5.6 +/- 2.1 vs. 4.1 +/- 1.8/4.3 +/- 1.6); (p < 0.001). All lesions sizes were significant better detected with 80 kVp images than with virtual 120 kVp and DSA-Images (80 kVp vs. 120 kVp: <10 mm: 34 vs. 19, p < 0.05; 10-20 mm:, 33 vs. 25, p < 0.05; >20 mm: 56 vs. 42, p < 0.05/80 kVp vs. DSA: <10 mm: 34 vs. 18 p < 0.05;10-20 mm: 33 vs. 24, p < 0.05; >20 mm: 56 vs. 41, p < 0.05). Number of detected small lesions <10 mm with 120 kVp compared to DSA-images were significant higher (19 vs. 13; p < 0.05), lesions 10-20 mm and >20 mm were measured statistically equally. Noise, SNR and CNR of 80 kVp images were higher compared to 120 kVp images. Image quality of 120 kVp images was higher compared to 80 kVp images. Conclusion: Low-kVp images of DECT datasets are more sensitive in detecting liver metastases of patients with uveal melanoma than virtual 120 kVp-and DSA images. (C) 2016 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 50 条
  • [31] Dual-energy CT of the abdomen
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 108 - 134
  • [32] Systemic Surveillance for Metastases in patients with Uveal Melanoma
    Choudhary, Maria
    Gupta, Akshay
    Bena, James
    Singh, Arun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [33] Dual-Energy CT of the Pancreas
    Mastrodicasa, Domenico
    Delli Pizzi, Andrea
    Patel, Bhavik Natvar
    SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (06) : 509 - 514
  • [34] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [35] Differentiation with the Dual-Energy CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 689 - 689
  • [36] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [37] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63
  • [38] Melanoma-specific survival of patients with uveal melanoma and liver metastases diagnosed between 2005 and 2021
    Wiens, Lisa
    Grozinger, Gerd
    Dittmann, Helmut
    Thiel, Karolin
    Leiter, Ulrike
    Amaral, Teresa
    Nanz, Lena
    Flatz, Lukas
    Forschner, Andrea
    THERAPEUTIC ADVANCES IN MEDICAL ONCOLOGY, 2024, 16
  • [39] USEFULNESS OF DUAL-ENERGY CT FOR DETECTION OF LIVER IRON DEPOSITION IN TRANSFUSION-DEPENDENT PATIENTS
    Kobayashi, H.
    Yoshimura, N.
    Kasami, T.
    Katagiri, T.
    Nemoto, H.
    Kawamoto, K.
    Ushiki, T.
    Shibasaki, Y.
    Moriyama, M.
    Takizawa, J.
    Narita, M.
    Sone, H.
    Masuko, M.
    HAEMATOLOGICA, 2015, 100 : 789 - 789
  • [40] Imaging of Body Iron Stores in Transfusion-Dependent Patients By Liver Dual-Energy CT
    Kobayashi, Hironori
    Yoshimura, Norihiko
    Ushiki, Takashi
    Shibasaki, Yasuhiko
    Moriyama, Masato
    Takizawa, Jun
    Narita, Miwako
    Sone, Hirohito
    Masuko, Masayoshi
    BLOOD, 2014, 124 (21)