CAPILLARY ELECTROPHORESIS OF DNA RESTRICTION FRAGMENTS WITH SOLUTIONS OF ENTANGLED POLYMERS

被引:87
|
作者
KLEEMISS, MH [1 ]
GILGES, M [1 ]
SCHOMBURG, G [1 ]
机构
[1] MAX PLANCK INST COAL RES,DEPT CHROMATOG & ELECTROPHORESIS,W-4330 MULHEIM,GERMANY
关键词
D O I
10.1002/elps.1150140179
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation of DNA restriction fragments in dilute buffer solutions of network forming polymers such as linear polyacrylamide (PAA), hydroxyethyl cellulose (HEC) and polyvinylalcohol (PVA) in phosphate buffer were investigated. PVA in buffers already became inhomogeneous after a few separations with resultant deterioration of resolution. Hydroxylic polymers, capable of forming suitable networks in buffers, are strongly adsorbed to fused silica surfaces suppressing the electroosmotic flow. These polymers could be applied as surface modifiers in capillaries, filled with buffer media containing other polymers such as PAA. Suppression of the electroosmotic flow by adsorbed HEC at pH 7 was slightly more effective than with PVA but the former coating was less stable due to weaker binding to the fused silica surface. Good separations of restriction fragments could be achieved with solutions of PAA or HEC as separation media after surface pretreatment of fused silica capillaries by either PVA rinsing or coating according to Hjerten [41].
引用
收藏
页码:515 / 522
页数:8
相关论文
共 50 条
  • [31] USE OF GLUCOMANNAN FOR THE SEPARATION OF DNA FRAGMENTS BY CAPILLARY ELECTROPHORESIS
    IZUMI, T
    YAMAGUCHI, M
    YONEDA, K
    ISOBE, T
    OKUYAMA, T
    SHINODA, T
    JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) : 41 - 46
  • [32] Analytical and micropreparative capillary gel electrophoresis of DNA fragments
    Rónai, Z
    Guttman, A
    AMERICAN LABORATORY, 2000, 32 (14) : 28 - +
  • [33] INJECTION BIAS OF DNA FRAGMENTS IN CAPILLARY ELECTROPHORESIS WITH SIEVING
    KLEPARNIK, K
    GARNER, M
    BOCEK, P
    JOURNAL OF CHROMATOGRAPHY A, 1995, 698 (1-2) : 375 - 383
  • [34] Temporal analysis of DNA restriction digests by capillary electrophoresis
    Stebbins, MA
    Schar, CR
    Peterson, CB
    Sepaniak, MJ
    JOURNAL OF CHROMATOGRAPHY B, 1997, 697 (1-2): : 181 - 188
  • [35] Dynamics of DNA electrophoresis in dilute and entangled polymer solutions
    Noguchi, H
    JOURNAL OF CHEMICAL PHYSICS, 2000, 112 (21): : 9671 - 9678
  • [36] ENHANCED SEPARATION OF DNA RESTRICTION FRAGMENTS BY CAPILLARY GEL-ELECTROPHORESIS USING FIELD-STRENGTH GRADIENTS
    GUTTMAN, A
    WANDERS, B
    COOKE, N
    ANALYTICAL CHEMISTRY, 1992, 64 (20) : 2348 - 2351
  • [37] Band broadening of DNA fragments isolated by polyacrylamide gel electrophoresis in capillary electrophoresis
    Kaneta, Takashi
    Ogura, Takehito
    Yamato, Shuhei
    Imasaka, Totaro
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (03) : 431 - 435
  • [38] Properties of entangled polymer solutions in high-performance capillary electrophoresis
    Bergman, M
    Claessens, H
    Cramers, C
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (01) : 19 - 26
  • [39] Capillary electrophoresis microchip for direct amperometric detection of DNA fragments
    Jang, You-Cheol
    Jha, Sandeep Kumar
    Chand, Rohit
    Islam, Kamrul
    Kim, Yong-Sang
    ELECTROPHORESIS, 2011, 32 (08) : 913 - 919
  • [40] CAPILLARY ZONE ELECTROPHORESIS FOR ANALYSIS OF DNA FRAGMENTS, PROTEINS AND PEPTIDES
    RIGHETTI, PG
    CHIARI, M
    ANNALES DE BIOLOGIE CLINIQUE, 1993, 51 (3-5) : 195 - 196