THREE DIMENSIONAL LINEAR MEASUREMENT OF PROXIMAL TIBIA IN MEDIAL AND LATERAL APPROACH FOR BONE HARVESTING

被引:0
|
作者
Nam, Woong [1 ]
Park, Won-Se [1 ]
Jeong, Ho-Gul [1 ,2 ]
Hu, Kyung-Seok [3 ]
Cha, In-Ho [1 ]
机构
[1] Yonsei Univ, Coll Dent, Dept Oral & Maxillofacial Surg, 134 Shinchon Dong, Seoul 120752, South Korea
[2] Yonsei Univ, Human Identificat Reserch Ctr, Seoul, South Korea
[3] Yonsei Univ, Human Identificat Reserch Ctr, Oral Sci Res Ctr, Coll Dent,Dept Oral Biol,Div Anat & Dev Biol,Brai, Seoul, South Korea
关键词
Proximal tibial bone harvesting; Medial approach; Lateral approach; Three dimensional measurement; V-works;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : The aim of this study was simply assessing linear measurements in the lateral and medial approach, respectively, for bone harvesting using anatomic and three-dimensional (3D) computed tomographic (CT) analyses on a dried cadaveric proximal tibia. In addition, the availability of the three-dimensional computed tomographic (3D-CT) analysis was also estimated. Materials and methods : Ten dried proximal tibia were obtained from five Korean cadavers. Four the reference points, the SM (superior-medial), IM (inferior-medial), SL (superior-lateral), and IL (inferior-lateral) were marked around the tibial tuberosity. The PM (posterior-medial) and PL (posterior-lateral) points were randomly marked at points farthest from the lateral and medial reference points, respectively, in the posterior border of the superior articular surface of both condyles. All measurements were obtained on the dried proximal tibia. After computed tomography had been performed, the three dimensional images were reconstructed using V works 4.0 (TM) (Cybermed Inc., Seoul, Korea), and the length between the reference points were measured three dimensionally using the method described above. The error between the mean actual and mean 3D-CT measurements was calculated in order to determine the availability of the three dimensional computed tomographic analysis. Results : The length between the reference points was greatest at the IL-PM, which averaged 65.39 mm +/- 10.35. This was followed by the SL-PM with 63.24 mm +/- 8.10, the IM-PL with 58.09 mm +/- 10.02, and the SM-PL with 51.99 mm +/- 9.06. The differences between the IL-PM and SM-PL were 13.4 mm. The mean values were 55.04 mm in the medial approach and 64.32 mm in the lateral approach, and the differences between medial and lateral were 9.28 mm. The error between the mean actual and mean 3D-CT measurements was 0.31% and the standard deviation was 0.28%. Conclusion : The anatomical and three dimensional computed tomographic analysis indicates that there was only a 9.28 mm linear difference between the lateral and medial approach. This is consistent with previous studies, which showed that there was little difference between the two approaches in terms of the bone volume. In addition, the error (0.31%) and the standard deviation (0.28%) were considered low, demonstrating high accuracy of 3D-CT. Therefore it can be used in preoperative treatment planning.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 50 条
  • [31] Simulation on the internal structure of three-dimensional proximal tibia under different mechanical environments
    Fang, Juan
    Gong, He
    Kong, Lingyan
    Zhu, Dong
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [32] Simulation on the internal structure of three-dimensional proximal tibia under different mechanical environments
    Juan Fang
    He Gong
    Lingyan Kong
    Dong Zhu
    BioMedical Engineering OnLine, 12
  • [33] Characterization of three-dimensional anatomic shapes using principal components: Application to the proximal tibia
    Hafner, B.J.
    Zachariah, S.G.
    Sanders, J.E.
    Medical and Biological Engineering and Computing, 2000, 38 (01): : 9 - 16
  • [34] Characterisation of three-dimensional anatomic shapes using principal components: application to the proximal tibia
    Hafner, BJ
    Zachariah, SG
    Sanders, JE
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (01) : 9 - 16
  • [35] Characterisation of three-dimensional anatomic shapes using principal components: Application to the proximal tibia
    B. J. Hafner
    S. G. Zachariah
    J. E. Sanders
    Medical and Biological Engineering and Computing, 2000, 38 : 9 - 16
  • [36] ARTICULAR SURFACE OF THE MEDIAL PROXIMAL TIBIA IS ALIGNED PARALLEL TO THE GROUND IN THREE-DIMENSIONAL SPACE UNDER WEIGHT-BEARING CONDITIONS FOR HEALTHY AND OSTEOARTHRITIC KNEES
    Mochizuki, T.
    Koga, Y.
    Mori, T.
    Nishino, K.
    Tanifuji, O.
    Kobayashi, K.
    Koga, H.
    Omori, G.
    Tanabe, Y.
    Sakamoto, M.
    Endo, N.
    OSTEOARTHRITIS AND CARTILAGE, 2020, 28 : S240 - S241
  • [37] PROXIMAL TIBIAL EXTENSION MEDIAL ROTATION OSTEOTOMY TO CORRECT KNEE FLEXION CONTRACTURE AND LATERAL ROTATION DEFORMITY OF TIBIA AFTER POLIO
    ASIRVATHAM, R
    ROONEY, RJ
    WATTS, HG
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (05) : 646 - 651
  • [38] Quantification of the Effect of Vertical Bone Resection of the Medial Proximal Tibia for Achieving Soft Tissue Balancing in Total Knee Arthroplasty
    Ahn, Ji Hyun
    Lee, Sung Hyun
    Kang, Ho Won
    CLINICS IN ORTHOPEDIC SURGERY, 2016, 8 (01) : 49 - 56
  • [39] Influence of three variables on the stresses in a three-dimensional model of a proximal tibia-total knee implant construct
    Kopparti, Partha Sarathi
    Lewis, Gladius
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2007, 17 (01) : 19 - 28
  • [40] Microdamage in bone: A three-dimensional approach
    O'Brien, FJ
    Taylor, D
    Dickson, GR
    Lee, TC
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 155 - 160