ELECTRON PION SEPARATION WITH THE H1 LAR CALORIMETERS

被引:0
|
作者
ANDRIEU, B
BAN, J
BARRELET, E
BERNARDI, G
BESANCON, M
BINDER, E
BLUME, H
BORRAS, K
BOUDRY, V
BRISSON, V
CAMPBELL, A
CARLI, T
COLOMBO, M
COUTURES, C
COZZIKA, G
CVACH, J
DAVID, M
DELBUONO, L
DELCOURT, B
DEVEL, M
DINGUS, P
DRESCHER, A
DUBOC, J
EBBINGHAUS, R
EGLI, S
FELTESSE, J
FENG, ZY
FLAUGER, W
FLEISER, M
GAMERDINGER, K
GAYLER, J
GOERLICH, L
GOLDBERG, M
GRASSLER, R
GREIF, H
HAGUENAUER, M
HAJDUK, L
HAMON, O
HARTZ, P
HAYDAR, R
HILDESHEIM, W
HUOT, N
JABIOL, MA
JACHOLKOWSKA, A
JAFFRE, M
JUNG, H
KIESLING, C
KOLANOSKI, H
KORBEL, V
KORN, M
机构
[1] RHEIN WESTFAL TH AACHEN,INST PHYS 3,W-5100 AACHEN,GERMANY
[2] INST NUCL PHYS,PL-31342 KRAKOW,POLAND
[3] UNIV DORTMUND,INST PHYS,W-4600 DORTMUND 50,GERMANY
[4] CTR ETUD SACLAY,DAPNIA,GIF SUR YVETTE,FRANCE
[5] DESY,W-2000 HAMBURG 52,GERMANY
[6] SLOVAK ACAD SCI,INST EXPTL PHYS,CS-80936 BRATISLAVA,SLOVAKIA
[7] MOSCOW THEORET & EXPTL PHYS INST,MOSCOW,RUSSIA
[8] MAX PLANCK INST PHYS & ASTROPHYS,MUNICH,GERMANY
[9] UNIV PARIS 11,LAL,CNRS,IN2P3,F-91405 ORSAY,FRANCE
[10] UNIV PARIS 06,LPNHE,PARIS,FRANCE
[11] UNIV PARIS 07,CNRS,IN2P3,F-75221 PARIS 05,FRANCE
[12] CZECHOSLOVAK ACAD SCI,INST PHYS,CS-11142 PRAGUE 1,CZECH REPUBLIC
[13] CHARLES UNIV,CTR NUCL,PRAGUE,CZECH REPUBLIC
[14] UNIV ZURICH,INST PHYS,CH-8006 ZURICH,SWITZERLAND
关键词
D O I
10.1016/0168-9002(94)90870-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performances of the Hl liquid argon calorimeter modules for the energy measurements and identification of electons are studied with test data taken at CERN in the energy range 5 to 166 GeV. Various electron identification estimators exploiting global or detailed shower characteristics are studied and compared. The usage of impact position measurements is also discussed. A best combination of robust shower estimators leads typically to pi-misidentification probabilities in the range 1.5 to 5.0 x 10(-3) at 30 GeV for 95% electron detection efficiency. This further reduces to approximately 10(-4) for these pions to be misidentified as electrons below 25 GeV.
引用
收藏
页码:492 / 506
页数:15
相关论文
共 50 条
  • [21] H1 Collaboration: Search for excited fermions with the H1 detector
    Nuclear Physics, Section B, 483 (1-2):
  • [22] Histone H1 and chromatin interactions in human fibroblast nuclei after H1 depletion and reconstitution with H1 subfractions
    Kostova, NN
    Srebreva, L
    Markov, DV
    Rundquist, I
    CYTOMETRY PART A, 2004, 58A (02) : 132 - 139
  • [23] Antihistamines H1
    Faure, Sebastien
    ACTUALITES PHARMACEUTIQUES, 2009, 48 (490): : 49 - 52
  • [24] 大学H1
    李宇博
    课堂内外创新作文(高中版), 2019, (10) : 40 - 40
  • [25] The H1 backward calorimeter BEMC and its inclusive electron trigger
    Ban, J
    Bauhoff, W
    Bruncko, D
    Brune, C
    Claassen, F
    Duhm, HH
    Eisen, E
    Eschweiler, M
    Ferencei, J
    Fleischer, M
    Gartner, W
    Gennis, M
    Glazov, A
    Griebel, R
    Guelck, C
    Harning, M
    Hartmann, T
    Hoelzke, U
    Javorek, M
    Kasselmann, HP
    Krasny, MW
    Krivan, F
    Krause, H
    Koch, J
    Kuhn, U
    Kurca, T
    Langkau, R
    Lipka, M
    Maracek, R
    Matysek, M
    Meier, K
    Murin, P
    Novak, T
    Olszowska, J
    Peppel, E
    Pichler, C
    Rathje, K
    Reimer, P
    Reinshagen, S
    Scobel, W
    Schirm, N
    Schrader, C
    Schrieber, S
    Seman, M
    Skvaril, P
    Spalek, J
    Wunderlich, R
    Zarbock, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (03): : 399 - 414
  • [26] H1 backward calorimeter BEMC and its inclusive electron trigger
    Ban, J.
    Bauhoff, W.
    Bruncko, D.
    Brune, C.
    Claassen, F.
    Duhm, H.H.
    Eisen, E.
    Eschweiler, M.
    Ferencei, J.
    Fleischer, M.
    Gartner, W.
    Gennis, M.
    Glazov, A.
    Griebel, R.
    Guelck, C.
    Elsevier Science B.V., Amsterdam, Netherlands (372):
  • [27] Histone H1
    Wolffe, AP
    INTERNATIONAL JOURNAL OF BIOCHEMISTRY & CELL BIOLOGY, 1997, 29 (12): : 1463 - 1466
  • [28] Hadronic response and e/pi separation with the H1 lead/fibre calorimeter
    Appuhn, RD
    Arndt, C
    Barrelet, E
    Barschke, R
    Bassler, U
    Buchholz, R
    Bruncko, D
    Chechelnitski, S
    Claxton, B
    Cozzika, G
    Cvach, J
    DagoretCampagne, S
    Dau, WD
    Deckers, H
    Deckers, T
    Deschamps, F
    Dirkmann, M
    Dowdell, J
    Efremenko, V
    Eisenhandler, E
    Eliseev, AN
    Ferencei, J
    Fominykh, B
    Goerlach, U
    Gorbov, LA
    Gorelov, I
    Hajduk, L
    Herynek, I
    Hladky, J
    Hutte, M
    Hutter, H
    Janczur, W
    Janoth, J
    Jonsson, L
    Kolanoski, H
    Korbel, V
    Krivan, F
    Lacour, D
    Lamarche, F
    Landon, MPJ
    Laforge, B
    Laporte, JF
    Lehner, F
    Maracek, R
    Meier, K
    Meyer, A
    Migliori, A
    Moreau, F
    Muller, G
    Murin, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03): : 395 - 412
  • [29] EFFECT OF BUFFER COMPOSITION ON THE MIGRATION ORDER AND SEPARATION OF HISTONE H1 SUBTYPES
    LINDNER, H
    HELLIGER, W
    SARG, B
    MERANER, C
    ELECTROPHORESIS, 1995, 16 (04) : 604 - 610
  • [30] ORGANIZATION AND EXPRESSION OF H1 HISTONE AND H1 REPLACEMENT HISTONE GENES
    DOENECKE, D
    ALBIG, W
    BOUTERFA, H
    DRABENT, B
    JOURNAL OF CELLULAR BIOCHEMISTRY, 1994, 54 (04) : 423 - 431