REDUCTION OF SIGNAL FLUCTUATION IN FUNCTIONAL MRI USING NAVIGATOR ECHOES

被引:192
|
作者
HU, XP [1 ]
KIM, SG [1 ]
机构
[1] UNIV MINNESOTA, SCH MED, CTR MAGNET RESONANCE RES, MINNEAPOLIS, MN USA
关键词
NAVIGATOR ECHO; FUNCTIONAL MAGNETIC RESONANCE IMAGING; FLASH; MOTION ARTIFACT REDUCTION;
D O I
10.1002/mrm.1910310505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional magnetic resonance imaging is sensitive to signal fluctuations due to physiological motion and system instability. In this paper, motion-related signal fluctuations are studied, and a method that uses navigator echoes to monitor and compensate for signal fluctuations in a gradient-echo sequence is described. The technique acquires a ''navigator'' signal before the application of the phase-encoding and readout gradients and corrects the phase of the subsequently acquired imaging data. This technique was implemented on a 4 Tesla whole body system and validated on normal volunteers. With this technique, temporal fluctuations in image intensity were substantially reduced and improved functional activation maps were obtained.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 50 条
  • [31] Anticonvulsant effects on functional MRI signal characteristics
    Samji, R
    Edwards, J
    Goodyeart, B
    Federico, B
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2005, 238 : S142 - S142
  • [32] Retrospective motion gating in cardiac MRI using a simultaneously acquired navigator
    Kim, Byungjai
    Seo, Hyunseok
    Kim, Dongchan
    Park, HyunWook
    NMR IN BIOMEDICINE, 2018, 31 (03)
  • [34] Retrospective image correction in the presence of nonlinear temporal magnetic field changes using multichannel navigator echoes
    Versluis, M. J.
    Sutton, B. P.
    de Bruin, P. W.
    Boernert, P.
    Webb, A. G.
    van Osch, M. J.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (06) : 1836 - 1845
  • [35] Functional MRI study of mild Alzheimer's disease using amplitude of low frequency fluctuation analysis
    Xi Qian
    Zhao Xiao-hu
    Wang Pei-jun
    Guo Qi-hao
    Yan Chao-gan
    He Yong
    CHINESE MEDICAL JOURNAL, 2012, 125 (05) : 858 - 862
  • [36] Motion tracking in MR-guided liver therapy by using navigator echoes and projection profile matching
    Tokuda, J
    Morikawa, S
    Dohi, T
    Hata, N
    ACADEMIC RADIOLOGY, 2004, 11 (01) : 111 - 120
  • [37] In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis
    Song, HK
    Wehrli, FW
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (05) : 947 - 953
  • [38] Rapid Six-Degree-of-Freedom Motion Detection Using Prerotated Baseline Spherical Navigator Echoes
    Liu, Junmin
    Drangova, Maria
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 506 - 514
  • [39] Quantitative separation of overlapping echoes using the analytic signal magnitude
    Sippel, Teresa M.
    Moses, Dwane J.
    Gammell, Paul M.
    Review of Progress in Quantitative Nondestructive Evaluation, 1988, 7 A : 875 - 880
  • [40] Signal Changes in Hippocampal Subfields during Controlled Breathing Patterns by Using Functional MRI
    Chan-A Park
    Seung-Bae Yang
    Kyung-Jin Lee
    Yeong-Bae Lee
    Hang-Keun Kim
    Chang-Ki Kang
    Journal of the Korean Physical Society, 2019, 74 : 718 - 723