AIRBORNE ASBESTOS LEVELS IN BUILDINGS - MAINTENANCE WORKER AND OCCUPANT EXPOSURES

被引:0
|
作者
PRICE, B
CRUMP, KS
BAIRD, EC
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A substantial number of air samples have been collected during the past few years to measure airborne asbestos levels in buildings with asbestos-containing materials (ACM). These samples fall into two categories: (i) samples collected to measure the exposure of workers while they were engaged in routine maintenance and repair activities; and (ii) samples collected during normal building activity to measure prevalent levels in buildings. The measurements derived from these samples have been compiled and summarized to provide estimates of the airborne asbestos exposure of workers engaged in routine maintenance and repair work and by other building occupants. These data indicate that maintenance and repair workers in buildings with ACM, after accounting for the frequency and duration of these types of activities, have annual exposure levels ranging from a median value of 0.002 fibers per cubic centimeter (f/cc) per year to 0.02 f/cc per year at the 90th percentile. Building occupants not involved in maintenance and repair work experience average exposure levels ranging from 0.00003 f/cc to 0.0005 f/cc.
引用
收藏
页码:357 / 374
页数:18
相关论文
共 50 条
  • [31] Cumulative Incidence Of Asbestosis And Exposure Levels In A Chinese Asbestos Worker Cohort
    Wang, X.
    Courtice, M. N.
    Lin, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [32] Evaluation of airborne asbestos concentrations associated with the maintenance of brakes on an industrial overhead crane
    Ferracini, Tyler
    Brown, Sarah
    Simmons, Brooke
    Avens, Heather
    Gaffney, Shannon
    Dotson, Scott
    Sahmel, Jennifer
    INHALATION TOXICOLOGY, 2024, 36 (06) : 391 - 405
  • [33] ASSESSMENT OF BUILDING MAINTENANCE MANAGEMENT PRACTICE AND OCCUPANT SATISFACTION OF SCHOOL BUILDINGS IN PERAK, MALAYSIA
    Yong, C. Y.
    Sulieman, M. Zailan
    JURNAL TEKNOLOGI, 2015, 75 (05): : 57 - 61
  • [34] Airborne fungi and bacteria - Background levels in office buildings
    Schillinger, JE
    Vu, T
    Bellin, P
    JOURNAL OF ENVIRONMENTAL HEALTH, 1999, 62 (02) : 9 - 14
  • [35] Airborne asbestos exposures associated with gasket and packing replacement: A simulation study and meta-analysis
    Madl, Amy K.
    Hollins, Dana M.
    Devlin, Kathryn D.
    Donovan, Ellen P.
    Dopart, Pamela J.
    Scott, Paul K.
    Perez, Angela L.
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2014, 69 (03) : 304 - 319
  • [36] Occupant density impact on building maintenance: Data-driven approach for university buildings
    D'Orazio, Marco
    Di Giuseppe, Elisa
    Bernardini, Gabriele
    AUTOMATION IN CONSTRUCTION, 2022, 141
  • [37] Asbestos exposure and radiological abnormalities among maintenance and custodian workers in buildings with friable asbestos-containing materials
    Mireille Matrat
    Jean-Claude Pairon
    Ann-Gaëlle Paolillo
    Nathalie Joly
    Yuriko Iwatsubo
    Ewa Orlowski
    Marc Letourneux
    Jacques Ameille
    International Archives of Occupational and Environmental Health, 2004, 77 : 307 - 312
  • [38] Airborne Asbestos Fiber Concentration in Buildings: Surveys Carried Out in Latium (Central Italy)
    Bruno, Maria R.
    Campopiano, Antonella
    Olori, Angelo
    Angelosanto, Federica
    Sinopoli, Francesco
    Cannizzaro, Annapaola
    MINERALS, 2023, 13 (02)
  • [39] AIRBORNE FIBER CONTROL IN BUILDINGS DURING ASBESTOS MATERIAL REMOVAL BY AMENDED WATER METHODOLOGY
    SAWYER, RN
    ROHL, AN
    LANGER, AM
    ENVIRONMENTAL RESEARCH, 1985, 36 (01) : 46 - 55
  • [40] Asbestos exposure and radiological abnormalities among maintenance and custodian workers in buildings with friable asbestos-containing materials
    Matrat, M
    Pairon, JC
    Paolillo, AG
    Joly, N
    Iwatsubo, Y
    Orlowski, E
    Letourneux, M
    Ameille, J
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2004, 77 (05) : 307 - 312