NUCLEAR-MAGNETIC-RESONANCE IMAGING OF FLOW FOR A SHEAR-THINNING POLYMER IN CYLINDRICAL COUETTE GEOMETRY

被引:38
|
作者
ROFE, CJ [1 ]
LAMBERT, RK [1 ]
CALLAGHAN, PT [1 ]
机构
[1] MASSEY UNIV,DEPT PHYS & BIOPHYS,PALMERSTON NORTH,NEW ZEALAND
关键词
D O I
10.1122/1.550597
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
We have developed a small concentric cylinder Couette cell which fits into the 10 mm sample space of a NMR electromagnet. The 2 mm fluid gap provides sufficiently high shear rates to result in shear-thinning behavior in polymer solutions, and the limited sample volume makes possible the study of gram quantities of material. By using Fourier encoding for velocity combined with microimaging to 50 mum resolution, we are able to provide precise and accurate maps of velocity across the cell. Profiles obtained from these maps are fitted using a power-law fluid model to yield the exponent n. For water we obtain 1.0, as expected, while for the polymer solution the effective exponent decreases to around 0.4 as the rotation speed and hence the shear rate, is increased. These data are compared, and found to be consistent with, the results of conventional viscometry using a cone-and-plate geometry.
引用
收藏
页码:875 / 887
页数:13
相关论文
共 50 条
  • [41] Study of shear-thinning/thickening effects on plane Couette-Poiseuille flow with uniform crossflow
    Yu-quan Liu
    Ke-qin Zhu
    Applied Mathematics and Mechanics, 2014, 35 : 549 - 566
  • [42] Numerical Simulation of Sterilization Processes for Shear-Thinning Food in Taylor-Couette Flow Systems
    Masuda, Hayato
    Hubacz, Robert
    Shimoyamada, Makoto
    Ohmura, Naoto
    CHEMICAL ENGINEERING & TECHNOLOGY, 2019, 42 (04) : 859 - 866
  • [43] COMPARISON OF DOPPLER AND NUCLEAR-MAGNETIC-RESONANCE IMAGING FOR MEASUREMENTS OF VOLUME FLOW
    GARDIN, JM
    JUH, SC
    JO, JM
    ANDREWS, D
    EY, S
    NALCIOGLU, O
    CLINICAL RESEARCH, 1987, 35 (01): : A104 - A104
  • [44] QUANTITATIVE MEASUREMENTS OF FLOW ACCELERATION BY MEANS OF NUCLEAR-MAGNETIC-RESONANCE IMAGING
    LI, TQ
    ODBERG, L
    POWELL, RL
    MCCARTHY, MJ
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 109 (02): : 213 - 217
  • [45] COMPARISON OF DOPPLER AND NUCLEAR-MAGNETIC-RESONANCE IMAGING FOR MEASUREMENTS OF VOLUME FLOW
    GARDIN, JM
    JUH, SC
    JO, JM
    ANDREWS, D
    NALCIOGLU, O
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A19 - A19
  • [46] THE EFFECTS OF RANDOM DIRECTIONAL DISTRIBUTED FLOW IN NUCLEAR-MAGNETIC-RESONANCE IMAGING
    AHN, CB
    LEE, SY
    NALCIOGLU, O
    CHO, ZH
    MEDICAL PHYSICS, 1987, 14 (01) : 43 - 48
  • [47] NUCLEAR-MAGNETIC-RESONANCE IMAGING OF A SINGLE CELL
    AGUAYO, JB
    BLACKBAND, SJ
    SCHOENIGER, J
    MATTINGLY, MA
    HINTERMANN, M
    NATURE, 1986, 322 (6075) : 190 - 191
  • [48] CONTRAST AGENTS FOR NUCLEAR-MAGNETIC-RESONANCE IMAGING
    DIAS, MHM
    LAUTERBUR, PC
    BIOLOGICAL TRACE ELEMENT RESEARCH, 1987, 13 : 229 - 239
  • [49] Viscoelasticity and shear-thinning effects on bio-polymer solution and suspended particle behaviours under oscillatory curve Couette flow conditions
    Safari, Alaleh
    Emami, Nazanin
    Cervantes, Michel Jose
    Biosurface and Biotribology, 2018, 4 (01): : 1 - 17
  • [50] NUCLEAR-MAGNETIC-RESONANCE IMAGING IN A PATIENT WITH A PACEMAKER
    INBAR, S
    LARSON, J
    BURT, T
    MAFEE, M
    EZRI, MD
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1993, 305 (03): : 174 - 175