INVESTIGATION OF METHODS OF ENZYME IMMOBILIZATION ON A COATED-WIRE ELECTRODE FOR THE DEVELOPMENT OF MICRO-BIOSENSORS

被引:26
|
作者
TAGUCHI, H
ISHIHARA, N
OKUMURA, K
SHIMABAYASHI, Y
机构
[1] Laboratory of Biological Chemistry, Faculty of Bioresources, Mie University, Tsu, Mie
关键词
D O I
10.1016/S0003-2670(00)80492-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tridodecylamine- and carboxyl-substituted poly(vinyl chloride)-based hydrogen ion-selective coated-wire electrodes are investigated as transducers for micro-biosensors. Various methods for immobilization of enzyme on the electrode were evaluated by using penicillinase as a model enzyme. The best method was immobilization with glutaraldehyde on the electrode previously modified with bovine serum albumin in the presence of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide to increase the amount of immobilized enzyme. A stable, large potential change is obtainable even in salt-containing samples with this sensor. The possibility of the practical use of such a micro-biosensor is suggested. © 1990.
引用
收藏
页码:159 / 162
页数:4
相关论文
共 50 条
  • [21] Pentacyclooctaaza as a neutral carrier in coated-wire ion-selective electrode for nickel(II)
    Mazloum-Ardakani, M
    Salavati-Niasari, M
    Amini, MK
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (2-3) : 259 - 264
  • [22] Silver(I)-selective coated-wire electrode based on an octahydroxycalix[4]arene derivative
    Mazloum-Ardakani, M
    Ensafi, AA
    Salavati-Niasari, M
    Mirhoseini, H
    ANALYTICAL SCIENCES, 2003, 19 (08) : 1187 - 1190
  • [23] Silver(I)-selective Coated-wire Electrode Based on an Octahydroxycalix[4]arene Derivative
    Mohammad Mazloum Ardakani
    Ali Asghar Ensafi
    Mohammad Salavati Niasari
    Hossain Mirhoseini
    Analytical Sciences, 2003, 19 : 1187 - 1190
  • [24] ENZYME SENSORS BASED ON COATED-WIRE ELECTRODE - USE OF CARBOXYL-SUBSTITUTED POLYVINYL-CHLORIDE) AS A SUPPORT FOR IMMOBILIZING PENICILLINASE
    ANZAI, J
    SHIMADA, M
    OSA, T
    CHEN, C
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (11) : 4133 - 4137
  • [25] Overoxidized polypyrrole film directed DNA immobilization for construction of electrochemical micro-biosensors and simultaneous determination of serotonin and dopamine
    Jiang, XH
    Lin, XQ
    ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) : 145 - 151
  • [26] Highly selective lead(II) coated-wire electrode based on a new Schiff base
    Mazloum-Ardakani, M
    Ensafi, AA
    Naeimi, H
    Dastanpour, A
    Shamlli, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (1-2) : 441 - 445
  • [27] Coated-wire copper(II)-selective electrode based on phenylglyoxal-α-monoxime ionophore
    A. Firooz
    M. Mazloum
    J. Safari
    M. Amini
    Analytical and Bioanalytical Chemistry, 2002, 372 : 718 - 722
  • [28] Coated-wire silver ion-selective electrode based on silver complex of cyclam
    Sil, A
    Ijeri, VS
    Srivastava, AK
    ANALYTICAL SCIENCES, 2001, 17 (04) : 477 - 479
  • [29] Silver-selective coated-wire electrode based on resorc[4]arene neutral carrier
    Mazloum-Ardakani, M
    Salavati-Niasari, M
    Chahooki, SHM
    Amini, MK
    ELECTROANALYSIS, 2002, 14 (05) : 376 - 381
  • [30] PERCHLORATE ION-SELECTIVE COATED-WIRE ELECTRODE BASED ON A MACROCYCLIC SCHIFFS BASE COMPLEX
    LIU, JH
    MASUDA, Y
    SEKIDO, E
    ANALYST, 1990, 115 (08) : 1089 - 1092