Size-dependent thresholding as an optimal method for tumor volume delineation on positron emission tomography computed tomography: A Phantom study

被引:7
|
作者
Gupta, Arun [1 ]
Sharma, Punit [1 ]
Patel, Chetan D. [1 ]
Maharjan, Sagar [1 ]
Pandey, Anil [2 ]
Kumar, Rakesh [1 ]
Malhotra, Arun [1 ]
机构
[1] All India Inst Med Sci, Inst Rotary Canc Hosp, Dept Nucl Med, New Delhi, India
[2] All India Inst Med Sci, Inst Rotary Canc Hosp, Dept Hlth Phys, New Delhi, India
来源
INDIAN JOURNAL OF NUCLEAR MEDICINE | 2011年 / 26卷 / 01期
关键词
Positron emission tomography-computed tomography; phantom thresholding; tumor volume;
D O I
10.4103/0972-3919.84598
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Use of a fixed threshold value for tumor volume delineation in positron emission tomography (PET) images will ignore the effect of size of the lesion and source to background ratio (SBR). The purpose of this Phantom study was to evaluate the effect of the size of the lesion and SBR on the threshold to be used for PET tumor volume delineation. Materials and Methods: Phantom used in the study comprised a sphere-cylinder assembly containing six spheres of different inner diameters (1.10, 1.35, 1.44, 1.50, 1.83 and 1.93 cm) with inner volumes of 0.70, 1.30, 1.50, 1.77, 3.22 and 3.82 cm', respectively. The scans were acquired with SBR of 6:01, 7:01, 8:01 and 10:01. These SBRs were calculated from 42 patients with lymphoma to simulate clinical images. PET tumor volume was calculated using RT_Image software at different threshold values (40, 45, 50, 55, 60, 65, 70 and 75% of SUV..) for each sphere at different SBRs. The threshold intensity value at which the calculated volume was nearly equal to actual volume of spheres was considered as the standardized threshold intensity (STI) value. Results: STI values depended on the diameter of the sphere and not on the SBR. It is found that 40% threshold is suitable for calculating the volume of any lesion with diameter greater than 1.83 cm, 60% for diameter greater than 1.35 cm but less than 1.83 cm, and 75% for diameter less than 1.35 cm. Conclusion: Size-dependent thresholding is an accurate and reproducible method of tumor volume delineation on PET-computed tomography (CT).
引用
收藏
页码:22 / 26
页数:5
相关论文
共 50 条
  • [21] FDG positron emission tomography/computed tomography studies of Wilms’ tumor
    A. K. M. Moinul Hossain
    Barry L. Shulkin
    Michael J. Gelfand
    Humayun Bashir
    Najat C. Daw
    Susan E. Sharp
    Helen R. Nadel
    Jeffrey S. Dome
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1300 - 1308
  • [22] FDG positron emission tomography/computed tomography studies of Wilms' tumor
    Hossain, A. K. M. Moinul
    Shulkin, Barry L.
    Gelfand, Michael J.
    Bashir, Humayun
    Daw, Najat C.
    Sharp, Susan E.
    Nadel, Helen R.
    Dome, Jeffrey S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (07) : 1300 - 1308
  • [23] The Use of Positron Emission Computed Tomography and Computed Tomography in the Treatment of Gynecological Malignant Tumor
    Yang, Lang
    Hu, Xiaoxia
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (09) : 2062 - 2066
  • [24] Using Positron Emission Tomography/Computed Tomography Imaging as a Novel Method to Study Fish
    Browning, Z. S.
    Wilkes, A.
    MacKenzie, D.
    Lenox, M.
    Patterson, R.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2011, 50 (05): : 737 - 737
  • [25] Phantom study of an in-house amplitude-gating respiratory method with silicon photomultiplier technology positron emission tomography/computed tomography
    Bailly, Pascal
    Bouzerar, Roger
    Galan, Romain
    Meyer, Marc-Etienne
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 221
  • [26] Intelligent Labeling of Tumor Lesions Based on Positron Emission Tomography/Computed Tomography
    Ye, Shiping
    Chen, Chaoxiang
    Bai, Zhican
    Wang, Jinming
    Yao, Xiaoxaio
    Nedzvedz, Olga
    SENSORS, 2022, 22 (14)
  • [27] Phantom design for quality control of Positron Emission Tomography/Computed Tomography (PET/CT) imaging
    Mu'minah, I. A. S.
    Ratianto
    Nurlely
    Soejoko, D. S.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [28] Evaluation of dosimetry and image of very low-dose computed tomography attenuation correction for pediatric positron emission tomography/computed tomography: phantom study
    Bahn, Y. K.
    Park, H. H.
    Lee, C. H.
    Kim, H. S.
    Lyu, K. Y.
    Dong, K. R.
    Chung, W. K.
    Cho, J. H.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (04): : 353 - 360
  • [29] VOLUME ASSESSMENT ACCURACY IN COMPUTED TOMOGRAPHY: A PHANTOM STUDY
    Prionas, N. D.
    Ray, S.
    Boone, J. M.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (01) : 120 - 120
  • [30] Volume assessment accuracy in computed tomography: a phantom study
    Prionas, Nicolas D.
    Ray, Shonket
    Boone, John M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 168 - 180