Provision of frequency containment reserve with an aggregate of air handling units

被引:5
|
作者
Rominger, Julian [1 ]
Kern, Fabian [1 ]
Schmeck, Hartmut [2 ]
机构
[1] FZI Res Ctr Informat Technol, Haid & Neu Str 10-14, D-76137 Karlsruhe, Germany
[2] Karlsruhe Inst Technol, Karlsruhe, Germany
来源
关键词
Frequency containment reserve; Air handling unit; Demand response; Balancing reserve;
D O I
10.1007/s00450-017-0361-8
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Following political strategy changes with the goal to reduce greenhouse gas emissions, the German power system has experienced a great penetration of intermittent renewable energy sources. The volatile electricity generation of renewable energy sources requires greater flexibility not only on the electricity supply but also on the demand side. The ventilation of buildings represents a largely untapped resource for demand response measures such as control reserve. Due to the quick reaction speed and inertia of the air balance of supplied buildings, electric motors of air handling units qualify to provide frequency containment reserve. In this paper we present a system architecture according to standards by the German transmission system operators to provide frequency containment reserve with an aggregate of air handling units. At an industrial site containing workshop and office buildings a prototype of the system has been installed and prequalified by the transmission system operators to provide almost 300 kW of frequency containment reserve.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 50 条
  • [21] Low frequency noise from air handling units ABB points the way forward
    Noise and Vibration Worldwide, 2001, 32 (05):
  • [22] Provision of Frequency Containment Reserves with Batteries and Power-to-Heat
    Jomaux, Julien
    Mercier, Thomas
    De Jaeger, Emmanuel
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [23] Torsional resonance analysis in air handling units
    Zeng, PW
    JOURNAL OF SOUND AND VIBRATION, 2001, 248 (03) : 557 - 566
  • [24] Evaluating Virus Containment Efficiency Of Air-Handling Systems
    Manassypov, Renat
    ASHRAE JOURNAL, 2020, 62 (07) : 17 - 23
  • [25] Re: Fresh air-handling units
    Gatley, Don
    ASHRAE JOURNAL, 2007, 49 (03) : 20 - 20
  • [26] Torsional resonance analysis in air handling units
    Zeng, PW
    SOUND AND VIBRATION, 2001, 35 (05): : 18 - 22
  • [27] Real heat recovery with air handling units
    Roulet, CA
    Heidt, FD
    Foradini, F
    Pibiri, MC
    ENERGY AND BUILDINGS, 2001, 33 (05) : 495 - 502
  • [28] Modeling of frequency containment reserve prices with econometrics and artificial intelligence
    Kraft, Emil
    Keles, Dogan
    Fichtner, Wolf
    JOURNAL OF FORECASTING, 2020, 39 (08) : 1179 - 1197
  • [29] Analysis of the Minimum Activation Period of Batteries in Frequency Containment Reserve
    Hollinger, Raphael
    Cortes, Agustin Motte
    Erge, Thomas
    Engel, Bernd
    2017 14TH INTERNATIONAL CONFERENCE ON THE EUROPEAN ENERGY MARKET (EEM 17), 2017,
  • [30] Providing Frequency Containment Reserve With Cellular Network Power Infrastructure
    Dias, Leonardo
    Jaumard, Brigitte
    IEEE ACCESS, 2024, 12 : 163787 - 163804