RECENT DEVELOPMENTS IN ELECTROSPRAY MASS-SPECTROMETRY INCLUDING IMPLEMENTATION ON AN ION-TRAP

被引:15
|
作者
HENION, J
WACHS, T
MORDEHAI, A
机构
[1] Diagnostic Laboratory, New York State College of Veterinary Medicine, Drug Testing and Toxicology, Ithaca, NY 14850
关键词
ELECTROSPRAY MASS SPECTROMETRY; ION TRAP; TANDEM MASS SPECTROMETRY (MS/MS); LC/MS;
D O I
10.1016/0731-7085(93)80082-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometry (MS) may be the ultimate detection technique when combined with modern condensed phase separation sciences. The technique combines sensitivity with excellent specificity, so the pharmaceutical analyst can obtain definitive information regarding components separated in a mixture. Thus, mass spectrometric detection not only provides evidence of a chromatographic peak, but it also provides important information including molecular weight and structural information enabling identification of the components. The coupling of an atmospheric pressure ionization (API) mass spectrometer to most of the separation science techniques offers a simpler alternative from earlier nonroutine, less sensitive systems where the vacuum systems struggled to handle the liquid effluent from these systems. Contemporary sensitive and analytically rugged API systems can be operated unattended for extended periods of time thus reducing the cost per sample to a reasonable value especially given the wealth of information provided. Although the mass spectrometer is more complicated than conventional spectroscopic detectors, present day API systems effectively decouple the liquid-phase separation inlet from the high-vacuum system where mass analysis occurs. The ability to form gas-phase ions at atmospheric pressure and sample primarily the analyte ions into the mass spectrometer promises a bright future for combining on-line condensed phase separation science techniques with mass spectrometry. The increasing ease of performing these experiments offers new analytical opportunities for pharmaceutical laboratories.
引用
收藏
页码:1049 / 1061
页数:13
相关论文
共 50 条
  • [1] ASPECTS OF RECENT DEVELOPMENTS IN ION-TRAP MASS-SPECTROMETRY
    NOURSE, BD
    COOKS, RG
    ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 1 - 21
  • [2] Recent developments in ion-trap mass spectrometry and related technologies
    Brancia, Francesco L.
    EXPERT REVIEW OF PROTEOMICS, 2006, 3 (01) : 143 - 151
  • [3] PEPTIDE SEQUENCE-ANALYSIS BY ELECTROSPRAY QUADRUPOLE ION-TRAP TANDEM MASS-SPECTROMETRY
    YATES, NA
    SHABANOWITZ, J
    HUNT, DF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 132 - ANYL
  • [4] ANALYSIS OF NEUROPEPTIDES BY PERFUSION LIQUID-CHROMATOGRAPHY ELECTROSPRAY ION-TRAP MASS-SPECTROMETRY
    LIN, HY
    VOYKSNER, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (04) : 333 - 338
  • [5] MULTIRESIDUE PESTICIDE ANALYSIS BY ION-TRAP MASS-SPECTROMETRY
    CAIRNS, T
    CHIU, KS
    NAVARRO, D
    SIEGMUND, E
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) : 971 - 988
  • [6] ION-TRAP MASS-SPECTROMETRY OF EXTERNALLY GENERATED IONS
    MCLUCKEY, SA
    VANBERKEL, GJ
    GOERINGER, DE
    GLISH, GL
    ANALYTICAL CHEMISTRY, 1994, 66 (13) : A689 - A696
  • [7] CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION ION-TRAP MASS-SPECTROMETRY USING A SHEATHLESS INTERFACE
    RAMSEY, RS
    MCLUCKEY, SA
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (05) : 461 - 469
  • [8] CHARACTERIZATION OF CHLORINS WITHIN A NATURAL CHLORIN MIXTURE USING ELECTROSPRAY ION-TRAP MASS-SPECTROMETRY
    CHILLIER, XFD
    VANBERKEL, GJ
    GULACAR, FO
    BUCHS, A
    ORGANIC MASS SPECTROMETRY, 1994, 29 (11): : 672 - 678
  • [9] ELECTROSPRAY IONIZATION COMBINED WITH ION TRAP MASS-SPECTROMETRY
    VANBERKEL, GJ
    GLISH, GL
    MCLUCKEY, SA
    ANALYTICAL CHEMISTRY, 1990, 62 (13) : 1284 - 1295
  • [10] CONCERNING BLACK-HOLES IN ION-TRAP MASS-SPECTROMETRY
    MORAND, KL
    LAMMERT, SA
    COOKS, RG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (10) : 491 - 491