CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION ION-TRAP MASS-SPECTROMETRY USING A SHEATHLESS INTERFACE

被引:39
|
作者
RAMSEY, RS
MCLUCKEY, SA
机构
[1] Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee
关键词
MASS SPECTROMETRY; ONLINE CAPILLARY ELECTROPHORESIS; MS/MS ANALYSIS; SHEATHLESS ELECTROSPRAY SOURCE; PEPTIDES;
D O I
10.1002/mcs.1220070505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity that can be obtained with the quadrupole ion trap for on-line CE analysis using a sheathless electrospray interface and gold-tipped columns is examined. Capillaries of different i.d. are compared in continuous infusion experiments and the effects of sheath solvents on the signal for some peptides and proteins are illustrated. The sheathless CE/ITMS system using 20 mu m i.d. columns is shown to provide mid-attomole detection levels for leucine enkephalin in total ion electropherograms under full scan conditions. Good quality MS/MS spectra are also obtained for low femtomole injections of this peptide. (C) 1995 John Wiley & Sons, Inc.
引用
下载
收藏
页码:461 / 469
页数:9
相关论文
共 50 条
  • [1] A new sheathless electrospray interface for coupling of capillary electrophoresis to ion-trap mass spectrometry
    Bendahl, L
    Hansen, SH
    Olsen, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (24) : 2333 - 2340
  • [2] ONLINE CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF NUCLEOTIDES
    ZHAO, ZX
    WAHL, JH
    UDSETH, HR
    HOFSTADLER, SA
    FUCIARELLI, AF
    SMITH, RD
    ELECTROPHORESIS, 1995, 16 (03) : 389 - 395
  • [3] CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY USING AN ELECTROSPRAY IONIZATION INTERFACE
    SMITH, RD
    OLIVARES, JA
    NGUYEN, NT
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (05) : 436 - 441
  • [4] A novel sheathless interface for capillary electrophoresis/electrospray ionization mass spectrometry using an in-capillary electrode
    Cao, P
    Moini, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (05) : 561 - 564
  • [5] Sampling error in small-bore sheathless capillary electrophoresis electrospray-ionization mass spectrometry
    Valaskovic, GA
    McLafferty, FW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (07) : 825 - 828
  • [6] NEW DEVELOPMENTS IN MICROSCALE SEPARATIONS AND MASS-SPECTROMETRY FOR BIOMONITORING - CAPILLARY ELECTROPHORESIS AND ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    SMITH, RD
    WAHL, JH
    LIGHTWAHL, KJ
    WINGER, BE
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1993, 40 (2-3): : 147 - 158
  • [7] USE OF CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY IN THE ANALYSIS OF SYNTHETIC PEPTIDES
    ROSNACK, KJ
    STROH, JG
    SINGLETON, DH
    GUARINO, BC
    ANDREWS, GC
    JOURNAL OF CHROMATOGRAPHY A, 1994, 675 (1-2) : 219 - 225
  • [8] The Development of a Sheathless Interface for Capillary Electrophoresis Electrospray Ionization Mass Spectrometry Using a Cellulose Acetate Cast Capillary
    Ryan T. Johnson
    Nhan H. To
    John F. Stobaugh
    Craig E. Lunte
    Chromatographia, 2017, 80 : 1061 - 1067
  • [9] The Development of a Sheathless Interface for Capillary Electrophoresis Electrospray Ionization Mass Spectrometry Using a Cellulose Acetate Cast Capillary
    Johnson, Ryan T.
    To, Nhan H.
    Stobaugh, John F.
    Lunte, Craig E.
    CHROMATOGRAPHIA, 2017, 80 (07) : 1061 - 1067
  • [10] Capillary electrophoresis-electrospray ion-trap mass spectrometry for the separation of chlorophenols
    Jáuregui, O
    Moyano, E
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) : 125 - 133