QUANTITATION OF GLUCOSE-CONCENTRATION USING A GLUCOSE OXIDASE CATALASE ELECTRODE BY POTENTIOMETRIC MEASUREMENT

被引:29
|
作者
LIU, CC
WINGARD, LB
WOLFSON, SK
YAO, SJ
DRASH, AL
SCHILLER, JG
机构
[1] UNIV PITTSBURGH,SCH MED,DEPT PHARMACOL,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,SCH MED,DEPT NEUROL SURG,PITTSBURGH,PA 15260
[3] UNIV PITTSBURGH,SCH MED,DEPT PEDIAT,PITTSBURGH,PA 15260
来源
关键词
D O I
10.1016/0302-4598(79)85003-5
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [21] Potentiometric glucose determination in human serum samples with glucose oxidase biosensor based on iodide electrode
    E. Karakuş
    Ş. Pekyardımcı
    E. Kiliç
    Applied Biochemistry and Microbiology, 2013, 49 : 194 - 198
  • [22] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [23] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [24] A SYSTEM FOR THE ONLINE DETERMINATION OF GLUCOSE-CONCENTRATION
    LEUNG, KK
    PETERSEN, JN
    LEE, JM
    BIOPROCESS ENGINEERING, 1991, 7 (1-2): : 19 - 23
  • [25] VARIATIONS IN GLUCOSE-CONCENTRATION AROUND THE MOUTH
    WEATHERELL, JA
    STRONG, M
    ROBINSON, C
    RALPH, JP
    CARIES RESEARCH, 1988, 22 (02) : 116 - 116
  • [26] UTEROPLACENTAL GLUCOSE-UPTAKE VS MATERNAL GLUCOSE-CONCENTRATION
    HAY, WW
    BATTAGLIA, FC
    MESCHIA, G
    FEDERATION PROCEEDINGS, 1983, 42 (03) : 467 - 467
  • [27] COMBINATION OF MICRODIALYSIS AND GLUCOSE SENSOR FOR CONTINUOUS ON LINE MEASUREMENT OF THE SUBCUTANEOUS GLUCOSE-CONCENTRATION - THEORY AND PRACTICAL APPLICATION
    MEYERHOFF, C
    MENNEL, FJ
    BISCHOF, F
    STERNBERG, F
    PFEIFFER, EF
    HORMONE AND METABOLIC RESEARCH, 1994, 26 (11) : 538 - 543
  • [28] Electrochemical determination of glucose using polyaniline electrode modified by glucose oxidase
    Gvozdenovic, M. M.
    Jugovic, B. Z.
    Bezbradica, D. I.
    Antov, M. G.
    Knezevic-Jugovic, Z. D.
    Grgur, B. N.
    FOOD CHEMISTRY, 2011, 124 (01) : 396 - 400
  • [29] HIGHLY SENSITIVE GLUCOSE ELECTRODE USING GLUCOSE OXIDASE COLLAGEN FILM
    THEVENOT, DR
    COULET, PR
    STERNBERG, R
    GAUTHERON, DC
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1978, 5 (03): : 548 - 553
  • [30] THE FATE OF LABELED GLUCOSE MOLECULES IN THE RAT ADIPOCYTE - DEPENDENCE ON GLUCOSE-CONCENTRATION
    GLIEMANN, J
    REES, WD
    FOLEY, JA
    BIOCHIMICA ET BIOPHYSICA ACTA, 1984, 804 (01) : 68 - 76