INTRACRANIAL VASCULAR STENOSIS AND OCCLUSION - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY

被引:100
|
作者
KOROGI, Y
TAKAHASHI, M
MABUCHI, N
MIKI, H
SHIGA, H
WATABE, T
OUCHI, T
NAKAGAWA, T
HORIKAWA, Y
FUJIWARA, S
FURUSE, M
机构
[1] SOSEIKAI GEN HOSP,DEPT RADIOL,KYOTO,JAPAN
[2] EHIME UNIV,SCH MED,DEPT RADIOL,MATSUYAMA,EHIME,JAPAN
[3] KEIO UNIV,SCH MED,DEPT RADIOL,TOKYO,JAPAN
[4] SAITAMA MED SCH,DEPT RADIOL,SAITAMA,JAPAN
[5] KAMEDA MED CTR,DEPT RADIOL,CHIBA,JAPAN
[6] SHINSAPPORO NEUROSURG HOSP,DEPT NEUROSURG,SAPPORO,HOKKAIDO,JAPAN
[7] KYOTO PREFECTURAL UNIV MED,DEPT NEUROSURG,KYOTO 602,JAPAN
[8] KOHNAN HOSP,DEPT NEUROSURG,SENDAI,MIYAGI,JAPAN
[9] NAKATSUGAWA MUNICIPAL GEN HOSP,DEPT NEUROSURG,NAKATSUGAWA,JAPAN
关键词
BRAIN; MR; CEREBRAL BLOOD VESSELS; MR STUDIES; STENOSIS OR OBSTRUCTION; MAGNETIC RESONANCE; VASCULAR STUDIES;
D O I
10.1148/radiology.193.1.8090890
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the accuracy of three-dimensional, Fourier transform, time-of-flight magnetic resonance (MR) angiography in the detection of intracranial steno-occlusive diseases. MATERIALS AND METHODS: One hundred thirty-one patients (62 male and 69 female patients, aged 6-77 years [mean, 53 years 8 months]) underwent MR and conventional angiography for evaluation of possible intracranial vascular disease. A total of 502 arteries were assessed. Eight projections and a collapsed image postprocessed by means of a maximum-intensity projection algorithm were reviewed by five observers in a blinded manner, with conventional angiography as the standard. RESULTS: A total of 32 steno-occlusive lesions were available for review. Receiver operating characteristic analysis from the pooled data revealed overall sensitivities of 85% and 88% and specificities of 96% and 97% for the internal carotid artery and the middle cerebral artery, respectively. CONCLUSION: MR angiography is useful as the primary diagnostic tool for evaluating suspected intracranial steno-occlusive disease.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 50 条
  • [21] PULSE SEQUENCE STRATEGIES FOR VASCULAR CONTRAST IN TIME-OF-FLIGHT CAROTID MR-ANGIOGRAPHY
    TKACH, JA
    RUGGIERI, PM
    ROSS, JS
    MODIC, MT
    DILLINGER, JJ
    MASARYK, TJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06): : 811 - 820
  • [22] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH A SPECIALIZED GRADIENT HEAD COIL
    TKACH, JA
    RUGGIERI, PM
    DILLINGER, JJ
    ROSS, JS
    MODIC, MT
    MASARYK, TJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02): : 365 - 375
  • [23] A diagnostic pitfall for intracranial aneurysms in time-of-flight MR angiography: Small intracranial lipomas
    Kemmling, Andre
    Noelte, Ingo
    Gerigk, Lars
    Singer, Stephan
    Groden, Christoph
    Scharf, Johann
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) : W62 - W67
  • [24] POTENTIAL AND LIMITATIONS OF 2-DIMENSIONAL AND 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY IN THE DIAGNOSIS OF CAROTID-ARTERY STENOSIS
    NOLDEKE, HA
    FRIEDRICH, JM
    WALLNER, B
    WEIDENMAIER, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (06): : 566 - 572
  • [25] 2-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY IN ABDOMINAL AORTIC-ANEURYSM
    ARLART, IP
    GUHL, L
    ULBRICH, D
    EDELMAN, RR
    RADIOLOGE, 1993, 33 (07): : 420 - 426
  • [26] DETECTION OF INTRACRANIAL ANEURYSMS BY 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY
    HORIKOSHI, T
    FUKAMACHI, A
    NISHI, H
    FUKASAWA, I
    NEURORADIOLOGY, 1994, 36 (03) : 203 - 207
  • [27] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH A SURFACE COIL - EVALUATION IN 12 SUBJECTS
    HENDRIX, LE
    STRANDT, JA
    DANIELS, DL
    MARK, LP
    BORNE, JA
    CZERVIONKE, LF
    HAUGHTON, VM
    WILLIAMS, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (01) : 103 - 106
  • [28] SEQUENTIAL 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE CAROTID ARTERIES - VALUE OF VARIABLE EXCITATION AND POSTPROCESSING IN REDUCING VENETIAN BLIND ARTIFACT
    DING, XP
    TKACH, JA
    RUGGIERI, PR
    MASARYK, TJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) : 683 - 688
  • [29] INTRACRANIAL MR ANGIOGRAPHY - A DIRECT COMPARISON OF 3 TIME-OF-FLIGHT TECHNIQUES
    LEWIN, JS
    LAUB, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (02) : 381 - 387
  • [30] INTRACRANIAL MR ANGIOGRAPHY - A DIRECT COMPARISON OF 3 TIME-OF-FLIGHT TECHNIQUES
    LEWIN, JS
    LAUB, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (06) : 1133 - 1139