RESPIRATOR PERFORMANCE RATING TABLES FOR NONTEMPERATE ENVIRONMENTS

被引:0
|
作者
JOHNSON, AT [1 ]
GROVE, CM [1 ]
WEISS, RA [1 ]
机构
[1] CHEM RES DEV & ENGN CTR,DIV INDIVIDUAL PROTECT,ABERDEEN PROVING GROUND,MD 21010
来源
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL | 1992年 / 53卷 / 09期
关键词
D O I
10.1202/0002-8894(1992)053<0548:RPRTFN>2.0.CO;2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Respirator performance rating tables have been constructed for hot, humid (29-degrees-C, 95% RH); hot, dry (49-degrees-C, 30% RH); and cold, dry (-32-degrees-C, 70% RH) conditions. These tables convey expected wearer performance percentages compared to unmasked workers for various mask elements and work rates. The hot, humid condition was found to be the most severe overall. Many table entries approach 100%, thus leading to difficulties in correcting mask deficiencies.
引用
收藏
页码:548 / 555
页数:8
相关论文
共 50 条
  • [21] Respirator fit factor performance while sweating
    Caretti, DM
    Gardner, PD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1999, 60 (01): : 84 - 88
  • [22] The Effect of Sanitizing Treatments on Respirator Filtration Performance
    Schutz, Juerg A.
    Pierlot, Anthony P.
    Alexander, David L. J.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (02)
  • [23] Breathing simulator of workers for respirator performance test
    Yuasa, Hisashi
    Kumita, Mikio
    Honda, Takeshi
    Kimura, Kazushi
    Nozaki, Kosuke
    Emi, Hitoshi
    Otani, Yoshio
    INDUSTRIAL HEALTH, 2015, 53 (02) : 124 - 131
  • [24] Performance league tables - League tables are unreasonably simple
    Howell, J
    BRITISH MEDICAL JOURNAL, 2002, 324 (7336): : 542 - 542
  • [25] Particle size selectivity in respirator performance - Reply
    Myers, WR
    Zhuang, ZQ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1996, 57 (10): : 973 - 973
  • [26] Landmark Rating and Selection for SLAM in Dynamic Environments
    Hochdorfer, Siegfried
    Neumann, Heiko
    Schlegel, Christian
    INTELLIGENT AUTONOMOUS SYSTEMS 13, 2016, 302 : 401 - 414
  • [27] Rating scale measures of restorative components of environments
    Laumann, K
    Gärling, T
    Stormark, KM
    JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 2001, 21 (01) : 31 - 44
  • [28] RATING MANAGERS PERFORMANCE
    NOLL, HE
    HOSPITALS, 1983, 57 (05): : 34 - &
  • [29] The rating of photovoltaic performance
    Emery, K
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1999, 46 (10) : 1928 - 1931
  • [30] Rating of photovoltaic performance
    Natl Renewable Energy Lab, Golden, United States
    IEEE Trans. Electron Devices, 10 (1928-1931):