DESIGN EXPERIENCE ON SEISMICALLY ISOLATED BUILDINGS

被引:4
|
作者
GIULIANI, GC
机构
关键词
D O I
10.1016/0029-5493(91)90059-Q
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper describes the practical problems associated with the structural design of a group of seismically isolated buildings now under construction in Ancona, Italy. These structures are the first seismically isolated buildings in Italy. The Ancona region is in zone 2 of the Italian Seismic Code. It has a design acceleration of 0.07 g which corresponds to a ground surface acceleration of 0.25 g. The last significant earthquake was recorded on June 14, 1972, having a single shock-type wave with a peak acceleration of 0.53 g. Taking into account the aforesaid earthquake, the structural design of these new buildings was performed according to an acceleration spectrum which was different from the zone 2 seismic code and which provided protection for stronger ground motions. To minimize the cost of the structure, the buildings used ribbed plate decks, thus reducing the amount of material and the mass of the structures to be isolated. The design requirements, dynamic analysis performed, structural design, and practical engineering employed are reported in this paper. A comparison between the costs of a conventionally designed and a base-isolated structure is also reported. It shows a net savings of 7% for the base-isolated structure. The tests undertaken for certifying the mechanical properties of the isolators for both static and dynamic loads are also described, as is the full-scale dynamic test which is scheduled for next year (1990) for one of the completed buildings.
引用
收藏
页码:349 / 366
页数:18
相关论文
共 50 条
  • [31] Seismically isolated buildings in Italy: State-of-the-art review and applications
    Clemente, Paolo
    Martelli, Alessandro
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 119 : 471 - 487
  • [32] Numerical investigation of potential mitigation measures for poundings of seismically isolated buildings
    Polycarpou, Panayiotis C.
    Komodromos, Petros
    EARTHQUAKES AND STRUCTURES, 2011, 2 (01) : 1 - 24
  • [33] Necessity and adequacy of near-source factors for seismically isolated buildings
    Saifullah, Muhammad Khalid
    Alhan, Cenk
    EARTHQUAKES AND STRUCTURES, 2017, 12 (01) : 91 - 108
  • [34] Ultrasonic Lateral Displacement Sensor for Health Monitoring in Seismically Isolated Buildings
    Matsuya, Iwao
    Matsumoto, Fumiya
    Ihara, Ikuo
    SENSORS, 2015, 15 (07) : 17000 - 17012
  • [35] Effect of Superstructure Deformation Capacity on the Collapse Performance of Seismically Isolated Buildings
    Kitayama, Shoma
    Constantinou, Michael C.
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (07)
  • [36] Effect of superstructure modeling assumptions on the seismic performance of seismically isolated buildings
    Kitayama, Shoma
    Constantinou, Michael C.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (07): : 1805 - 1823
  • [37] Ground motion intensity measures for seismically isolated RC tall buildings
    Yang, Cantian
    Xie, Linlin
    Li, Aiqun
    Jia, Junbo
    Zeng, Demin
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 125
  • [38] Experimental investigation of the seismic performance of flexible pipes for seismically isolated buildings
    Xie, Linlin
    Yang, Cantian
    Li, Aiqun
    Lu, Jiaming
    Zeng, Demin
    ENGINEERING STRUCTURES, 2020, 222
  • [39] Evolutionary Constrained Design of Seismically Excited Buildings: Sensor Placement
    Rowhanimanesh, Alireza
    Khajekaramodin, Abbas
    Akbarzadeh-T, Mohammad-Reza
    APPLICATIONS OF SOFT COMPUTING: FROM THEORY TO PRAXIS, 2009, 58 : 159 - +
  • [40] Control design for seismically excited buildings: sensor and actuator reliability
    Alt, TR
    Jabbari, F
    Yang, JN
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (02): : 241 - 257