DIAGNOSIS AND QUANTITATIVE-EVALUATION OF SECUNDUM-TYPE ATRIAL SEPTAL-DEFECT BY TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY

被引:40
|
作者
MORIMOTO, K [1 ]
MATSUZAKI, M [1 ]
TOHMA, Y [1 ]
ONO, S [1 ]
TANAKA, N [1 ]
MICHISHIGE, H [1 ]
MURATA, K [1 ]
ANNO, Y [1 ]
KUSUKAWA, R [1 ]
机构
[1] YAMAGUCHI UNIV,SCH MED,DEPT INTERNAL MED,UBE,YAMAGUCHI 755,JAPAN
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1990年 / 66卷 / 01期
关键词
D O I
10.1016/0002-9149(90)90741-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transesophageal echocardiography (horizontal sector scan) was performed in 11 patients with secundum atrial septal defect (ASD). In all 11 patients, transesophageal echocardiography presented the definite visualization of the defect and a clear laminar shunt flow that showed its 2 peaks in late systole and late diastole. We estimated the size of ASD and a shunt volume across the defect by using transesophageal echocardiography. The defect size determined by transesophageal echocardiography was correlated with the surgical measurement (horizontal width, r = 0.92, p < 0.001; vertical length, r = 0.85, p < 0.01). A significant high correlation was shown between the shunt volume measured by transesophageal echocardiography and that by Fick's method (r = 0.87, p < 0.01). There was no significant correlation between the pulmonary to systemic flow volume (ratio) and the mean shunt flow velocity across ASD, although a high linear correlation was observed between the pulmonary to systemic flow ratio and the defect size in horizontal direction (r = 0.82, p < 0.01). Transesophageal echocardiography used for diagnosis and quantitative evaluation of ASD could be performed easily and satisfactorily within 10 minutes. Thus, transesophageal echocardiography is a useful method in evaluation of the defect size and the shunt flow volume of ASD. The mean shunt flow velocity was not a reliable index for estimating the shunt flow volume. The defect size might be a valuable determinant of left-to-right shunt volume in ASD. © 1990.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [41] MITRAL REGURGITATION ASSOCIATED WITH SECUNDUM ATRIAL SEPTAL-DEFECT
    PARNSINGHA, T
    CHAITHIRAPHAN, S
    PRACHUABMOH, K
    SAKIYALAK, P
    JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND, 1977, 60 (08): : 383 - 388
  • [42] Intracardiac Echocardiography Evaluation in Secundum Atrial Septal Defect Transcatheter Closure
    Mario Zanchetta
    Luigi Pedon
    Gianluca Rigatelli
    Antonio Carrozza
    Marco Zennaro
    Roberta Di Martino
    Eustaquio Onorato
    Pietro Maiolino
    CardioVascular and Interventional Radiology, 2003, 26 : 52 - 57
  • [43] MITRAL INCOMPETENCE AND SECUNDUM ATRIAL SEPTAL-DEFECT - AN ANGIOGRAPHIC AND ECHOCARDIOGRAPHIC STUDY OF 56 CASES OF ATRIAL SEPTAL-DEFECT
    FECHNER, J
    DROBINSKI, G
    LAURENCEAU, JL
    EVANS, JI
    BEJEAN, A
    MICHAT, L
    THOMAS, D
    GROSGOGEAT, Y
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1982, 75 (02): : 121 - 126
  • [44] STUDIES OF OSTIUM SECUNDUM TYPE OF ATRIAL SEPTAL-DEFECT WITH LEFT AXIS DEVIATION
    ANZAI, T
    KAWABE, M
    KOBAYASHI, G
    TANIGUCHI, T
    ONAI, H
    IIJIMA, T
    IESATO, H
    SAKAUCHI, G
    JOURNAL OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY, 1981, 29 (03): : 367 - 372
  • [45] LEFT-VENTRICULAR FUNCTION IN OSTIUM SECUNDUM TYPE ATRIAL SEPTAL-DEFECT
    OHASHI, H
    MIYAMOTO, T
    SHIMIZU, Y
    OZAWA, M
    SUEHIRO, S
    YAMASHITA, K
    MIWA, T
    OGAWA, N
    OKAMOTO, E
    JOURNAL OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY, 1980, 28 (10): : 1509 - 1516
  • [46] Diagnosis of a Fenestrated Secundum Atrial Septal Defect Detected by Real-Time Three-Dimensional Transesophageal Echocardiography
    Schisler, Travis
    Subramaniam, Kathirvel
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (03) : 980 - 982
  • [47] COLOR DOPPLER EVALUATION OF TYPE OF VENTRICULAR SEPTAL-DEFECT
    HELMCKE, F
    PINAMONTI, B
    COLVIN, EC
    MOOS, S
    ADEY, CK
    SOTO, B
    NANDA, NC
    CLINICAL RESEARCH, 1987, 35 (03): : A286 - A286
  • [48] SIGNIFICANCE OF AN ATRIAL SEPTAL ANEURYSM IN THE PRESENCE OF AN OSTIUM-SECUNDUM ATRIAL SEPTAL-DEFECT
    BRILI, S
    MCCLEMENTS, B
    CASTELLANOS, S
    APOSTOLIDOU, M
    BARBETSEAS, J
    PITSAVOS, C
    TOUTOUZAS, P
    CARDIOLOGY, 1995, 86 (05) : 421 - 425
  • [49] A COMPARISON OF 2 DIMENSIONAL ECHOCARDIOGRAPHY AND PULSED DOPPLER ECHOCARDIOGRAPHY FOR DIAGNOSIS OF VENTRICULAR SEPTAL-DEFECT
    COLO, J
    STEVENSON, JG
    PEARLMAN, AS
    CIRCULATION, 1982, 66 (04) : 232 - 232
  • [50] Efficacy and Safety of Transthoracic Echocardiography Alone in Transcatheter Closure of Secundum-Type Atrial Septal Defects in Adults
    Ding, Cheng
    Chang, Jia-Kan
    Lin, Chang-Chyi
    Wu, Yong-Jian
    Hsieh, Kai-Sheng
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (04): : 579 - 585