Parallel atomic force microscopy using cantilevers with integrated piezoresistive sensors and integrated piezoelectric actuators

被引:386
|
作者
Minne, SC
Manalis, SR
Quate, CF
机构
[1] E. L. Ginzton Laboratory, Stanford University, Stanford
关键词
D O I
10.1063/1.115317
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have fabricated and operated two cantilevers in parallel in a new mode for imaging with the atomic force microscope (AFM). The cantilevers contain both an integrated piezoresistive silicon sensor and an integrated piezoelectric zinc oxide (ZnO) actuator. The integration of sensor and actuator on a single cantilever allows us to simultaneously record two independent AFM images in the constant force mode. The ZnO actuator provides over 4 mu m of deflection at low frequencies (de) and over 30 mu m deflection at the first resonant frequency. The piezoresistive element is used to detect the strain and provide the feedback signal for the ZnO actuator. (C) 1995 American Institute of Physics.
引用
收藏
页码:3918 / 3920
页数:3
相关论文
共 50 条
  • [21] Piezoresistive sensors on AFM cantilevers with atomic resolution
    Jumpertz, R
    von der Hart, A
    Ohlsson, O
    Saurenbach, F
    Schelten, J
    MICROELECTRONIC ENGINEERING, 1998, 42 : 441 - 444
  • [22] Fabrication of fluid-compatible trilayer cantilevers with integrated piezoelectric actuators
    Neuenschwander, Matthias
    Maillard, Damien
    Hosseini, Nahid
    Kangul, Mustafa
    Villanueva, Luis G.
    Fantner, Georg E.
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 383
  • [23] Dual integrated actuators for extended range high speed atomic force microscopy
    Sulchek, T
    Minne, SC
    Adams, JD
    Fletcher, DA
    Atalar, A
    Quate, CF
    Adderton, DM
    APPLIED PHYSICS LETTERS, 1999, 75 (11) : 1637 - 1639
  • [24] Dual integrated actuators for extended range high speed atomic force microscopy
    E. L. Ginzton Laboratory, Stanford University, Stanford, CA 94305-4085, United States
    不详
    Appl Phys Lett, 11 (1637-1639):
  • [25] Atomic force microscopy using small cantilevers
    Walters, DA
    Viani, M
    Paloczi, GT
    Schaffer, TE
    Cleveland, JP
    Wendman, MA
    Gurley, G
    Elings, V
    Hansma, PK
    MICROMACHINING AND IMAGING, 1997, 3009 : 43 - 47
  • [26] AIN on polysilicon piezoelectric cantilevers for sensors/actuators
    Giordano, C.
    Ingrosso, I.
    Todaro, M. T.
    Maruccio, G.
    De Guido, S.
    Cingolani, R.
    Passaseo, A.
    De Vittorio, M.
    MICROELECTRONIC ENGINEERING, 2009, 86 (4-6) : 1204 - 1207
  • [27] Cantilevers with integrated sensor for time-resolved force measurement in tapping-mode atomic force microscopy
    Sarioglu, A. F.
    Solgaard, O.
    APPLIED PHYSICS LETTERS, 2008, 93 (02)
  • [28] Atomic force microscopy tips (cantilevers) as molecular nucleic acid sensors
    Koçum, C
    Ülgen, SD
    Çubukçu, E
    Piskin, E
    ULTRAMICROSCOPY, 2006, 106 (4-5) : 326 - 333
  • [29] Low-temperature atomic force microscope using piezoresistive cantilevers
    Thomson, RE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (08): : 3369 - 3372
  • [30] Integration of Magnetoresistive Sensors with Atomic Force Microscopy Cantilevers for Scanning Magnetoresistance Microscopy Applications
    Costa, M.
    Gaspar, J.
    Ferreira, R.
    Paz, E.
    Fonseca, H.
    Martins, M.
    Cardoso, S.
    Freitas, P.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,