USE OF COMBINED ZONE PLATES AS IMAGING OPTICS FOR HARD X-RAYS

被引:0
|
作者
Nalimov, A. G. [1 ]
Kotlyar, V. V. [1 ]
机构
[1] Samara State Aerosp Univ, Russian Acad Sci, Image Proc Syst Inst, Samara, Russia
关键词
combined zone plates; multi-order diffraction; X-ray;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have carried out modeling of an image formation in hard x-ray coherent radiation using a Rayleigh-Sommerfeld integral. Combined zone plates have been used to form the image. The resolution of the combined zone plate was numerically shown to increase up to 10 times (equaling 20 nm) when compared with a traditional Fresnel zone plate without any changes of the outermost zone width (205 nm). The zone plate consisted of 6 areas operating in 1, 3, 5, 7, 9 and 11 diffraction orders. An efficiency improvement of 42% has been numerically achieved in contrast to a traditional Fresnel zone plate used in the third diffraction order. For the combined zone plate, the efficiency of 3.7 % has been achieved.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [21] Imaging plates in radiography with neutrons, X-rays and electrons
    Rant, J
    Nemec, T
    Rihar, G
    Stade, J
    Kaling, M
    4TH INTERNATIONAL CONFERENCE OF SLOVENIAN SOCIETY FOR NONDESTRUCTIVE TESTING - APPLICATION OF CONTEMPORARY NONDESTRUCTIVE TESTING IN ENGINEERING, CONFERENCE PROCEEDINGS, 1997, : 137 - 149
  • [22] Stacked Fresnel zone plates for high energy x-rays
    Snigireva, Irina
    Snigirev, Anatoly
    Vaughan, Gavin
    Di Michiel, Marco
    Kohn, Viktor
    Yunkin, Vyacheslav
    Grigoriev, Maxim
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 998 - +
  • [23] Atomic layer deposition frequency-multiplied Fresnel zone plates for hard x-rays focusing
    Moldovan, Nicolaie
    Divan, Ralu
    Zeng, Hongjun
    Ocola, Leonidas E.
    De Andrade, Vincent
    Wojcik, Michael
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2018, 36 (01):
  • [24] Nanometer focusing of X-rays with modified reflection zone plates
    Michette, AG
    Pfauntsch, SJ
    Erko, A
    Firsov, A
    Svintsov, A
    OPTICS COMMUNICATIONS, 2005, 245 (1-6) : 249 - 253
  • [25] Nanometer focusing of hard x rays by phase zone plates
    Yun, W
    Lai, B
    Cai, Z
    Maser, J
    Legnini, D
    Gluskin, E
    Chen, Z
    Krasnoperova, AA
    Vladimirsky, Y
    Cerrina, F
    Di Fabrizio, E
    Gentili, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (05): : 2238 - 2241
  • [26] Imaging plume dynamics with ultrafast hard X-rays
    Shan, Fang
    Porter, Rhiannon
    Cheng, Neal
    Masiel, Daniel J.
    Guo, Ting
    ULTRAFAST PHENOMENA XV, 2007, 88 : 728 - +
  • [27] Quantitative phase imaging using hard x-rays
    Nugent, KA
    Gureyev, TE
    Cookson, DF
    Paganin, D
    Barnea, Z
    COHERENT ELECTRON-BEAM X-RAY SOURCES: TECHNIQUES AND APPLICATIONS, 1997, 3154 : 110 - 116
  • [28] Phase-contrast imaging with hard X-rays
    Fehlmann, M
    Knudsen, KD
    Pattison, P
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1997, 16 (18) : 1521 - 1524
  • [29] Emerging developments in tomographic imaging with hard X-rays
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII, 2021, 11840
  • [30] Multilevel stacked Fresnel zone plate for hard X-rays
    Haroutunyan, Levon
    Trouni, Karapet
    Kuyumchyan, Armen
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VIII, 2013, 8848